HP 3000 Manuals

FIELD MENU [ HP Data Entry and Forms Management System (VPLUS/V) ] MPE/iX 5.0 Documentation


HP Data Entry and Forms Management System (VPLUS/V)

FIELD MENU 

In case you want to assign special field characteristics, FORMSPEC
displays a Field Menu, illustrated in Figure 3-22, for each field
delimited during form design.  Each menu displays up to three lines of
the form, and marks the particular field to which the menu applies.  It
then displays the default field attributes of the field.  The Field Menus
are presented in the order the fields appear on the form layout, from
left to right, top to bottom.

You can change the default field attributes by typing new values and
pressing ENTER. If you do not want to change the defaults, simply press
NEXT to display the next Field Menu.  If you are designing simple forms,
in which all data is accepted and no special edits are performed, you can
skip all the Field Menus by pressing NEXT FORM. If you change the field
length or type, the screen length or type  of the associated ARB (if any)
is updated at the same time, but the ARB length and type  are not
changed.

The field attributes, all except length, can also be changed using
FORMSPEC in batch mode.  See Section 7 for more information.  Processing
specifications can be specified on the Field Menu.  See Section 4 for a
description.

	       Click here to view figure.
          Figure 3-22.  Field Menu 

Fields 

Num              (Display only) A number between 1 and 256 assigned by
                 FORMSPEC to the field at form layout.  The number is
                 permanently assigned to the field and is not changed
                 even if other field attributes or the position of the
                 field on the form layout changes.  However, if the field
                 tag is changed, a new field number is assigned to the
                 field.  The field numbers of a form can be renumbered in
                 screen order with the FORMSPEC batch mode command
                 RENUMBER, as described in Section 7.

Len              (Display only) The length of the field as determined
                 during form layout.

Name             Specify any USASCII name of up to 15 characters long; it
                 must start with an alphabetic character and may be
                 followed by any alphanumeric (A -Z, a-z, 0-9) or the
                 underline (_).  It cannot be one of the reserved words
                 listed earlier in Table 3-2.

Enh              Specify any combination of enhancements using up to four
                 characters:

                 H                Half Bright

                 I                Inverse video

                 U                Underline

                 B                Blinking

                 S                Security

                 1-8              Color (refer to Table 3-7)

                 NONE             No enhancement

                 Default HI

FType            Specify the field type:

                 D                Display only--cannot be modified by
                                  user.

                 R                Required--cannot be left blank.

                 O                Optional--may be left blank; edit
                                  checks and field phase processing
                                  specifications are skipped if the field
                                  is blank.

                 P                Process--may be left blank, but edit
                                  checks are performed and field phase
                                  processing specifications are executed
                                  even if the field is blank.

                 Default O

DType            Specify the data type:

                 CHAR             Specifies data to be a string of any
                                  characters.

                 NUM[n]           Specifies data to be numeric.  The
                                  maximum number of decimal places is
                                  indicated by the optional digit (n),
                                  where n is a value between 0 and 9.  An
                                  optional leading sign (+ or -) is
                                  allowed; as are commas and decimal
                                  points if correctly placed.

                 DIG              Specifies data to be a positive
                                  integer.  No sign, no comma, no decimal
                                  point allowed.

                 IMPn             Specifies data to be numeric with an
                                  assumed decimal point.  The assumed
                                  number of decimal places is indicated
                                  by the required digit (n), where n is a
                                  value between 0 and 9.  A sign and
                                  commas are allowed.  A decimal point is
                                  allowed but should not be entered.

                 MDY              Specifies data to be a date in the
                                  order month, day, year.

                 DMY              Specifies data to be a date in the
                                  order day, month, year.

                 YMD              Specifies data to be a date in the
                                  order year, month, day.

                 When Native Language Support is used, the symbols
                 used to indicate thousands and decimals are
                 language-dependent.  The names of months and their
                 abbreviations are accepted for each native language at
                 run-time.  For more information on Native Language
                 Support, see Section 8.

                 Default CHAR

Initial Value    Specify data to be displayed in the field when the form
                 is initially displayed.



MPE/iX 5.0 Documentation