| 1.4 Required Components for 1:1 Bandwidth with 4 Enclosures per Cabinet | ||||||||||||
| The following tables indicate the required number of components, depending on the total number of BladeSystem enclosures and type of of Voltaire interconnect at full bandwidth. | Back | |||||||||||
| TOC | ||||||||||||
| Table 1-4: 1-12 Enclosure Configurations Using 9024 Switches: Full Bandwidth | ||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Optional 9024 Leaf Chassis to Support Control and Utility Nodes | 9024 Spine Chassis | Total 9024 Switch Chassis | Maximum Number of 4x Link Cables | |||||||
| 1 - 3 | 0-24 | 2 | 2 | 2 | 48 | |||||||
| 4 - 6 | 0-24 | 2 | 4 | 4 | 96 | |||||||
| 7 - 9 | 0-24 | 2 | 8 | 8 | 192 | |||||||
| 10 - 12 | 0-24 | 2 | 8 | 8 | 192 | |||||||
| Table 1-5: 1-6 Enclosure Configurations Using 2004 Switches: Full Bandwidth | ||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9096 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 Port 4x Switch Cards | Maximum Number of 4x Link Cables | 9024 Leaf Chassis (24*4x) | |||||
| 2 - 3 | 0-24 | 1 | 3 | 4 | 2 | 48 | 0 | |||||
| 4 - 6 | 0-24 | 1 | 4 | 4 | 4 | 96 | 0 | |||||
| Table-1-6: 1-18 Enclosure Configurations Using 2012 Switches: Full Bandwidth | ||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9288 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 Port 4x Switch Cards | Maximum Number of 4x Link Cables | 9024 Leaf Chassis (24*4x) | |||||
| 2 -3 | 0-24 | 1 | 3 | 4 | 2 | 48 | 0 | |||||
| 4 - 6 | 0-24 | 1 | 4 | 4 | 4 | 96 | 0 | |||||
| 7 - 9 | 0-24 | 1 | 4 | 4 | 6 | 144 | 0 | |||||
| 10 - 12 | 0-24 | 1 | 4 | 4 | 8 | 192 | 0 | |||||
| 13 - 15 | 0-24 | 1 | 5 | 4 | 10 | 240 | 0 | |||||
| 16 - 18 | 0-24 | 1 | 5 | 4 | 12 | 288 | 0 | |||||
| Table 1-7: 19-36 Enclosure Configurations Using 2012 Switches | ||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9288 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 Port 4x Switch Cards | Max Number of 4x Link Cables | Optional 9024 Leaf Chassis to support Control and Utility Nodes) | |||||
| 19 - 21 | 0-24 | 2 | 6 | 8 | 14 | 336 | 2 | |||||
| 22 - 25 | 0-24 | 2 | 8 | 8 | 16 | 384 | 2 | |||||
| 26 - 28 | 0-24 | 2 | 8 | 8 | 18 | 432 | 2 | |||||
| 29 - 31 | 0-24 | 2 | 8 | 8 | 20 | 480 | 2 | |||||
| 32 - 34 | 0-24 | 2 | 10 | 8 | 22 | 528 | 2 | |||||
| 35 - 38 | 0-24 | 2 | 10 | 8 | 24 | 576 | 2 | |||||