| 1.4 Required Components for 2:1 Bandwidth with 3 Enclosures per Cabinet | |||||||||||||
| The following tables indicate the required number of components, depending on the total number of BladeSystem enclosures and type of of Voltaire interconnect at full bandwidth. | Back | ||||||||||||
| TOC | |||||||||||||
| Table 1-4: 1-24 Enclosure Configurations Using 9024 Interconnects: Full Bandwidth | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Optional 9024 Leaf Chassis (24*4x) | 9024 Spine Chassis | Total 9024 Switch Chassis | Maximum Number of 4x Link Cables | Minimum Number of Managed Switches | |||||||
| 1 - 3 | 0-24 | 0 | 1 | 1 | 24 | 1 | |||||||
| 4 - 6 | 0-24 | 2 | 2 | 2 | 48 | 2 | |||||||
| 7 - 9 | 0-24 | 2 | 4 | 4 | 96 | 2 | |||||||
| 10 - 12 | 0-24 | 2 | 4 | 4 | 96 | 2 | |||||||
| 13 - 15 | 0-24 | 2 | 8 | 8 | 192 | 2 | |||||||
| 16 - 18 | 0-24 | 2 | 8 | 8 | 192 | 2 | |||||||
| 19 - 21 | 0-24 | 2 | 8 | 8 | 192 | 2 | |||||||
| 22 - 24 | 0-24 | 2 | 8 | 8 | 192 | 2 | |||||||
| Table 1-5: 1-12 Enclosure Configurations Using 2004 Interconnects: Full Bandwidth | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9096 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 port 4X Switch Cards | Maximum Number of 4x Link Cables | Optional 9024 Leaf Chassis (24*4x) | ||||||
| 1 - 3 | 0-24 | 1 | 3 | 0 | 1 | 24 | 0 | ||||||
| 4 - 6 | 0-24 | 1 | 3 | 4 | 2 | 48 | 0 | ||||||
| 7 - 9 | 0-24 | 1 | 3 | 4 | 3 | 72 | 0 | ||||||
| 10 - 12 | 0-24 | 1 | 4 | 4 | 4 | 96 | 0 | ||||||
| Table 1-6: 1-36 Enclosure Configurations Using 2012 Interconnects: Full Bandwidth | |||||||||||||
| Server Blade Enclosures | Control + Utility Nodes | Number of Managed 9288 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 port 4X Switch Cards | Maximum Number of 4x Link Cables | Optional 9024 Leaf Chassis (24*4x) | ||||||
| 1 - 3 | 0-24 | 1 | 3 | 0 | 1 | 24 | 0 | ||||||
| 4 - 6 | 0-24 | 1 | 3 | 4 | 2 | 48 | 0 | ||||||
| 7 - 9 | 0-24 | 1 | 4 | 4 | 3 | 72 | 0 | ||||||
| 10 - 12 | 0-24 | 1 | 4 | 4 | 4 | 96 | 0 | ||||||
| 13 - 15 | 0-24 | 1 | 4 | 4 | 5 | 120 | 0 | ||||||
| 16 -18 | 0-24 | 1 | 4 | 4 | 6 | 144 | 0 | ||||||
| 19 -21 | 0-24 | 1 | 4 | 4 | 7 | 168 | 0 | ||||||
| 22 - 24 | 0-24 | 1 | 4 | 4 | 8 | 192 | 0 | ||||||
| 25 - 27 | 0-24 | 1 | 4 | 4 | 9 | 216 | 0 | ||||||
| 28 - 30 | 0-24 | 1 | 5 | 4 | 10 | 240 | 0 | ||||||
| 31 - 33 | 0-24 | 1 | 5 | 4 | 11 | 264 | 0 | ||||||
| 34 - 36 | 0-24 | 1 | 5 | 4 | 12 | 288 | 0 | ||||||
| Table 1-7: 37-72 Enclosure Configurations Using 2012 Interconnects: Full Bandwidth | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9288 Chassis | Total Number of Power Supplies | Number of Fabric Boards | Number of 24 port 4X Switch Cards | Maximum Number of 4x Link Cables | Optional 9024 Leaf Chassis (24*4x) | ||||||
| 37 - 39 | 0-24 | 2 | 6 | 8 | 14 | 336 | 2 | ||||||
| 40 - 42 | 0-24 | 2 | 6 | 8 | 14 | 336 | 2 | ||||||
| 43 - 45 | 0-24 | 2 | 8 | 8 | 16 | 384 | 2 | ||||||
| 46 - 48 | 0-24 | 2 | 8 | 8 | 16 | 384 | 2 | ||||||
| 49 - 51 | 0-24 | 2 | 8 | 8 | 18 | 432 | 2 | ||||||
| 52 - 54 | 0-24 | 2 | 8 | 8 | 18 | 432 | 2 | ||||||
| 55 - 57 | 0-24 | 2 | 8 | 8 | 20 | 480 | 2 | ||||||
| 58 - 60 | 0-24 | 2 | 8 | 8 | 20 | 480 | 2 | ||||||
| 61 - 63 | 0-24 | 2 | 8 | 8 | 22 | 528 | 2 | ||||||
| 64 - 66 | 0-24 | 2 | 10 | 8 | 22 | 528 | 2 | ||||||
| 67 - 69 | 0-24 | 2 | 10 | 8 | 24 | 576 | 2 | ||||||
| 70 - 72 | 0-24 | 2 | 10 | 8 | 24 | 576 | 2 | ||||||