NM and CM callable. Assigns the value of a particular job control word (JCW) in
the job control word table. Syntax |  |
CA U16 I16 PUTJCW(jcwname,jcwvalue,jcwstatus); |
Parameters |  |
- jcwname
character array (required) Passes the name of the JCW. This array can contain
up to 255 characters, beginning with a letter and ending with a
nonalphanumeric character, such as a blank. An @ causes all executing JCWs to be set to jcwvalue. - jcwvalue
16-bit unsigned integer by reference
(required) Passes the value of the JCW. - jcwstatus
16-bit signed integer by reference (required) Returns the execution status: - Value
Meaning - 0
Successful - 1
Error, jcwname greater than 255 characters - 2
Error, jcwname does not start with an alpha character - 3
Error, JCW table overflow (no JCW with this name
exists in table and unable to create new entry) - 4
Error, jcwname cannot be a valid JCW value - 5
Error, cannot assign a value to a system-reserved
JCW, or a read-only variable - 6
Warning, standard variable reclassified as a JCW - 7
Error, cannot reclassify predefined variable
Operation Notes |  |
If a JCW of the same name already exists in the table, only
its value is entered. If no entry exists for this name, an entry
is created and its value is entered. There are three types of JCWs in the system: An attempt to assign a value to a system-reserved JCW results
in an error. The system-reserved JCWs are: Related Information |  |
- Intrinsics
FINDJCW, GETJCW, SETJCW - Commands
SETJCW, SHOWJCW - Manuals
Interprocess Communication Programmer's
Guide and Command Interpreter Access and
Variables Programmer's Guide
|