Class Error 1

Class Error 1

Class error 1 is composed of three types of processor failures: register file, execution unit, and instruction unit.

Register File Failure

Register file messages take the form:

  • 11xx

where:

  • xx = detailed error number

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Test of the general registers 1, 2, and 31 fails. Second possible cause of the error may be the execution unit. Third possible cause of the error also may be the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Test of the general registers fails. Second possible cause of the error may be the execution unit. Third possible cause of the error also may be the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Test of the recovery counter or external interrupt enable mask fails. Second possible cause of the error may be the execution unit. Third possible cause of the error also may be the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Test of the temporary control registers fails. Second possible cause of the error may be the execution unit. Third possible cause of the error also may be the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Cross-talk occurs between general registers.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Crosstalk occurs among general registers and temporary registers.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

X and B bus bypass testing.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

General register 0 bypassed.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

General register 0 bypassed on a nullify.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the trap with interval timer fails.

ACTION

Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Interval timer is not incrementing. Second possible cause of the error may be the execution unit. Third possible cause of the error also may be the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

11
MESSAGE

No message. System halts. (E)

CAUSE

Interval timer is not causing a trap. Second possible cause of the error may be the instruction unit. Third possible cause of the error also may be the translation look-aside buffer.

ACTION

Contact your Hewlett-Packard Support Representative.

12
MESSAGE

No message. System halts. (E)

CAUSE

Recovery counter is not causing a trap. Second possible cause of the error may be the instruction unit. Third possible cause of the error also may be the translation look-aside buffer.

ACTION

Contact your Hewlett-Packard Support Representative.

15
MESSAGE

No message. System halts. (E)

CAUSE

Load to general register 0 modifies that register.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

Nullified instruction stored to register file

ACTION

Contact your Hewlett-Packard Support Representative.

17
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load word and modification (LDWM) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load word indexed and modification (LDWX,M) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

19
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load byte indexed and modification (LDBX,U,M) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

1A
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load half word indexed and modification (LDHX,U,M) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

1B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load halfword indexed and modification (LDWX,U,M) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the operation of the register file interlock fails.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load word and modification after (LDW,MA) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation for load word and modification before (LDW,MB) fails.

ACTION

Contact your Hewlett-Packard Support Representative.

23
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the move to control register (MTCTL) after load word (LDW) operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

2A
MESSAGE

No message. System halts. (E)

CAUSE

Nullified instruction after data trap stored to register file.

ACTION

Contact your Hewlett-Packard Support Representative.

2B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the address calculation of the load and modification that caused the data trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

2C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the ripple through recovery counter fails.

ACTION

Contact your Hewlett-Packard Support Representative.

2D
MESSAGE

No message. System halts. (E)

CAUSE

Cannot force overflow trap.

ACTION

Contact your Hewlett-Packard Support Representative.

2E
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the backup on recovery counter fails.

ACTION

Contact your Hewlett-Packard Support Representative.

2F
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the late nullify on recovery counter fails.

ACTION

Contact your Hewlett-Packard Support Representative.

31
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected recovery counter trap occurs. Second possible cause of the error may be the instruction unit. Third possible cause of the error also may be the translation look-aside buffer.

ACTION

Contact your Hewlett-Packard Support Representative.

32
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected external interrupt trap occurs. Second possible cause of the error may be the instruction unit. Third possible cause of the error also may be the translation look-aside buffer.

ACTION

Contact your Hewlett-Packard Support Representative.

40
MESSAGE

No message. System halts. (E)

CAUSE

Test of the external interrupt request register with zero fails.

ACTION

Contact your Hewlett-Packard Support Representative.

41
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the value of general register 1 after ADDIL instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

42
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the calculation of the return address with branch and link instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

43
MESSAGE

No message. System halts. (E)

CAUSE

Register file does not zero unused portion of the target register for LDH instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

44
MESSAGE

No message. System halts. (E)

CAUSE

Register file does not zero unused portion of the target register for LDB instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

45
MESSAGE

No message. System halts. (E)

CAUSE

Cannot distinguish between banks of the general registers.

ACTION

Contact your Hewlett-Packard Support Representative.

46
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter operation fails. Counter cannot count up.

ACTION

Contact your Hewlett-Packard Support Representative.

47
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter operation with nullify instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

48
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter operation with late nullify instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

49
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter operation with late nullify instruction caused by data trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

4A
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

4B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the recovery counter trap operation immediately after data trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

4C
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify external interrupt enable mask.

ACTION

Contact your Hewlett-Packard Support Representative.

4D
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify external interrupt request register.

ACTION

Contact your Hewlett-Packard Support Representative.

4E
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the external interrupt operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

4F
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify current privilege level after execution of the gateway instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

50
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the timing on board fails.

ACTION

Contact your Hewlett-Packard Support Representative.

51
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the external interrupt request register with high-priority machine check fails. (EIRR bit gets set with HPMC.)

ACTION

Contact your Hewlett-Packard Support Representative.

Execution Unit Failure

Execution unit messages take the form:

  • 14xx

where:

  • xx = detailed error number.

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test on this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Test of the data path through the barrel shifter fails.

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Shift by bit 0, 1, 2, 4, 6, 8, 16, or 31 fails.

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Pattern test of the 3/4-bit hardware boundaries fails.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Preshift by 0 bit for MOVE fails.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Extract sign/unsigned for a bit field fails.

ACTION

Contact your Hewlett-Packard Support Representative.

06
MESSAGE

No message. System halts. (E)

CAUSE

Timing critical path of instruction mix MTCTL and VEXTRS fails.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the shift amount register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Arithmetic/logical conditions fail.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Test of the unit conditions fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Test of the extract/logical conditions fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Test of the PSW C/B bit fails. Second cause of the error may be the register file.

ACTION

Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the shift and add conditions fails.

ACTION

Contact your Hewlett-Packard Support Representative.

11
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify shift one and add.

ACTION

Contact your Hewlett-Packard Support Representative.

12
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify shift two and add.

ACTION

Contact your Hewlett-Packard Support Representative.

13
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify shift three and add.

ACTION

Contact your Hewlett-Packard Support Representative.

14
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the load byte short with odd index fails.

ACTION

Contact your Hewlett-Packard Support Representative.

15
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the operation of the PSW's C/B bits with decimal correct (DCOR) instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the PSW's C/B bits with logical shift operation fails. (C/B gets updated.)

ACTION

Contact your Hewlett-Packard Support Representative.

17
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify operation of the logical add.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the PSW's C/B bits with logical add operation fails. (C/B gets updated.)

ACTION

Contact your Hewlett-Packard Support Representative.

19
MESSAGE

No message. System halts. (E)

CAUSE

Addition of two negative numbers cause overflow trap.

ACTION

Contact your Hewlett-Packard Support Representative.

1A
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify addition of two negative numbers.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the overflow conditions with logical ADD instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the overflow conditions with EXTRU logical instruction fails.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the extract signed instruction operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

Instruction Unit Failure

Instruction unit messages take the form:

  • 15xx

where:

  • xx = detailed error number.

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Condition branch test fails. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Condition add with no overflow fails. Second possible cause of the error is the execution unit Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Odd condition fails. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Test of the unit true condition fails. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Test of the ext/dep true condition fails. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Branch and link instruction cannot calculate the return address. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

09
MESSAGE

No message. System halts. (E)

CAUSE

Branch and vector instruction cannot return to the given address. Second possible cause of the error is the execution unit. Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the system mask portion of the PSW fails. Second possible cause of the error is the execution unit Third possible cause also may be the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the coprocessor fails. Second possible cause of the error is the execution unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the interrupt vector address or PC offset queue fails. Second possible cause of the error is the execution unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the interrupt processor status word fails. Second possible cause of the error is the execution unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0E
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the PC offset queue operation fails. (Cannot verify the functionality of the PSW Q bit.) Second possible cause of the error is the translation look-aside buffer.

ACTION

Contact your Hewlett-Packard Support Representative.

0F
MESSAGE

No message. System halts. (E)

CAUSE

Instruction unit cannot force trap. Second possible cause of the error is the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

PC offset queue does not hold the correct address after trap.

ACTION

Contact your Hewlett-Packard Support Representative.

17
MESSAGE

No message. System halts. (E)

CAUSE

IPSW does not receive the value of the PSW after trap.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Interrupt instruction register does not receive the value of the instruction that causes a trap.

ACTION

Contact your Hewlett-Packard Support Representative.

19
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the forced break instruction trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the forced illegal instruction trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the forced overflow trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the forced conditional trap fails.

ACTION

Contact your Hewlett-Packard Support Representative.

23
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the PSW's T bit during a verification of the forced branch taken trap.

ACTION

Contact your Hewlett-Packard Support Representative.

24
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the PSW's B bit.

ACTION

Contact your Hewlett-Packard Support Representative.

25
MESSAGE

No message. System halts. (E)

CAUSE

Cannot enable a high-priority machine check with PSW's M bit.

ACTION

Contact your Hewlett-Packard Support Representative.

26
MESSAGE

No message. System halts. (E)

CAUSE

Cannot disable the high-priority machine check with PSW's M bit.

ACTION

Contact your Hewlett-Packard Support Representative.

27
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the change of privilege with branch external (BE) instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

28
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the change of privilege with branch and link external (BLE) instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

29
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the change of privilege with branch vector (BV) instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

2A
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the privilege register trap.

ACTION

Contact your Hewlett-Packard Support Representative.

2B
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the privilege operation trap.

ACTION

Contact your Hewlett-Packard Support Representative.

2C
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the lower privilege transfer trap.

ACTION

Contact your Hewlett-Packard Support Representative.

2D
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the functionality of the higher privilege transfer trap.

ACTION

Contact your Hewlett-Packard Support Representative.

31
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected high-priority machine check trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the translation look-aside buffer (TLB).

ACTION

Contact your Hewlett-Packard Support Representative.

32
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected low parity machine check trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

33
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected illegal instruction trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

34
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected break instruction trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

35
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected privileged operation trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

36
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected privileged register trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

37
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected overflow trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

38
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected condition trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

39
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected assist emulation trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

3A
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected privilege transfer trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

3B
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected low-privilege transfer trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

3C
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected taken branch trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

3D
MESSAGE

No message. System halts. (E)

CAUSE

Unimplemented trap occurs. Second possible cause of the error is the register file. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

40
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the transfer of control/soft reset fails.

ACTION

Contact your Hewlett-Packard Support Representative.

41
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected high-priority machine check is found during forced TOC/soft reset.

ACTION

Contact your Hewlett-Packard Support Representative.

42
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify PCQ front after RFI with Q bit off.

ACTION

Contact your Hewlett-Packard Support Representative.

43
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify Assist Emulation trap, or cannot verify bit zero of CCR.

ACTION

Contact your Hewlett-Packard Support Representative.

44
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify coprocessor configuration register by forcing assist emulation trap.

ACTION

Contact your Hewlett-Packard Support Representative.

45
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify overflow trap with ADDIO instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

46
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected overflow trap occurs.

ACTION

Contact your Hewlett-Packard Support Representative.

47
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify index other than zero with BLR instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

48
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify index other than zero with BV instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

49
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify system mask (of PSW) with MTSM instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

4E
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify functionality of PSW's N bit. N bit is not set for nullified instruction when taken branch trap is taken.

ACTION

Contact your Hewlett-Packard Support Representative.

4F
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify functionality of PSW's N bit. When N bit is set RFI target is not nullified.

ACTION

Contact your Hewlett-Packard Support Representative.

51
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify functionality of PSW's X bit. (Cannot prevent data memory break trap by setting X bit.)

ACTION

Contact your Hewlett-Packard Support Representative.

52
MESSAGE

No message. System halts. (E)

CAUSE

Verification of PSW's V bit fails. (Cannot verify the remainder of the divide step.)

ACTION

Contact your Hewlett-Packard Support Representative.

53
MESSAGE

No message. System halts. (E)

CAUSE

Verification of PSW's C bit fails.

ACTION

Contact your Hewlett-Packard Support Representative.

54
MESSAGE

No message. System halts. (E)

CAUSE

Verification of IPSW in virtual mode fails.

ACTION

Contact your Hewlett-Packard Support Representative.

55
MESSAGE

No message. System halts. (E)

CAUSE

Verification of PCQ in high virtual address fails.

ACTION

Contact your Hewlett-Packard Support Representative.

56
MESSAGE

No message. System halts. (E)

CAUSE

Verification of small displacement in high virtual address fails.

ACTION

Contact your Hewlett-Packard Support Representative.

57
MESSAGE

No message. System halts. (E)

CAUSE

Verification of PSW when HPMC is forced by TLB parity error fails.

ACTION

Contact your Hewlett-Packard Support Representative.

58
MESSAGE

No message. System halts. (E)

CAUSE

Cannot force HPMC in virtual mode.

ACTION

Contact your Hewlett-Packard Support Representative.

59
MESSAGE

No message. System halts. (E)

CAUSE

Verification of IPSW in virtual mode fails.

ACTION

Contact your Hewlett-Packard Support Representative.

Class Error 2

Class error 2 is composed of translation look-aside buffer (TLB) and cache failures. These two types of errors are coded 23xx and 27xx.

Translation Look-Aside Buffer (TLB) Failure

translation look-aside buffer messages take the form:

  • 26xx

where:

xx = detailed error number.
00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurred at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read and write operation on the space registers through space ID fails.

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read and write operation on the space registers through MTSP fails.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read or write access to a page with proper protection and access right fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the write disable bit operation fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

06
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the public access operation fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the PSW P Bit operation fails. Second possible cause of the error is the cache unit. Third possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the data TLB MISS trap operation fails. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

09
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the non-access data TLB MISS trap operation fails. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the debug trap operation fails. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the dirty bit trap operation fails. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the virtual I/O trap operation fails. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the physical page number RAMs fails.

ACTION

Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Lower privilege trap does not occur. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

11
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the data path through PIDs fails.

ACTION

Contact your Hewlett-Packard Support Representative.

12
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the data path through PCSQ fails.

ACTION

Contact your Hewlett-Packard Support Representative.

13
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the I bit functionality fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

14
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the physical address generation or the physical page number RAM fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

15
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read and write with virtual address operation fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

Gateway instruction does not promote privilege to zero in a real mode. Second possible cause is the instruction unit. Third possible cause is the register file.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the privilege level generation with gateway instruction for page types 2 or 3 fails. Second possible cause is the instruction unit. Third possible cause is the register file.

ACTION

Contact your Hewlett-Packard Support Representative.

19
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the privilege level generation with gateway instruction for page types 4, 5, 6, or 7 fails. Second possible cause is the instruction unit. Third possible cause is the register file.

ACTION

Contact your Hewlett-Packard Support Representative.

1A
MESSAGE

No message. System halts. (E)

CAUSE

Gateway instruction does not promote privilege to zero in a virtual mode. Second possible cause is the instruction unit. Third possible cause is the register file.

ACTION

Contact your Hewlett-Packard Support Representative.

1B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the execution of the gateway instruction in delay slot of the branch fails. (No trap is generated.) Second possible cause is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

1C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the generation of a data memory protection trap fails. Second possible cause is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

1D
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the generation of an instruction memory protection trap fails. Second possible cause is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the ISR operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the IOR operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity generator and parity checking on the data TLB physical page number RAM fails. Second possible cause is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

23
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity generator and parity checking on the instruction TLB physical page number RAM fails. Second possible cause is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

26
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the memory protection trap with byte access fails.

ACTION

Contact your Hewlett-Packard Support Representative.

27
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the memory protection trap with half word access fails.

ACTION

Contact your Hewlett-Packard Support Representative.

28
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the memory protection trap with word access fails.

ACTION

Contact your Hewlett-Packard Support Representative.

29
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the instruction TLB MISS fault fails.

ACTION

Contact your Hewlett-Packard Support Representative.

2A
MESSAGE

No message. System halts. (E)

CAUSE

Cannot force data TLB MISS fault.

ACTION

Contact your Hewlett-Packard Support Representative.

2B
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify protection ID, access ID.

ACTION

Contact your Hewlett-Packard Support Representative.

2C
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify public pages.

ACTION

Contact your Hewlett-Packard Support Representative.

2D
MESSAGE

No message. System halts. (E)

CAUSE

Cannot distinguish between instruction CA and data CA with the diagnostic register.

ACTION

Contact your Hewlett-Packard Support Representative.

2E
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the two cycle opcode instruction fails. Cannot verify TLB FREZ.

ACTION

Contact your Hewlett-Packard Support Representative.

31
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected instruction TLB MISS fault occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

32
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected instruction memory protection trap occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

33
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected TLB MISS trap occurs. Second possible cause of the error is the instruction unit.

ACTION

contact your Hewlett-Packard Support Representative.

34
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected nonaccess instruction TLB MISS trap occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

35
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected nonaccess instruction TLB MISS trap occurs. Second possible cause of the error is the instruction unit

ACTION

Contact your Hewlett-Packard Support Representative.

36
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected data memory protection trap occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

37
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected data memory break trap occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

38
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected TLB dirty bit fault occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

39
MESSAGE

No message. System halts. (E)

CAUSE

Unexpected virtual device reference trap occurs. Second possible cause of the error is the instruction unit.

ACTION

Contact your Hewlett-Packard Support Representative.

40
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify the TLB indexing through its RAM.

ACTION

Contact your Hewlett-Packard Support Representative.

Cache Failure

cache messages take the form:

  • 27xx

where:

  • xx = detailed error number.

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error has occurred at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read/write protocol in the first and last set of data cache RAM fails.

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read or write address test operation on data cache fails. Second possible cause of the error is memory. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the read or write (data path test operation) on the data cache fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the half word or byte operation on the data cache fails. Second possible cause of the error is the register file unit. Third possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

06
MESSAGE

No message. System halts. (E)

CAUSE

data cache cannot set enable interrupt request register (EIRR) bits. Second possible cause of the error is the register file unit.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the data cache dirty bit, miss or flush operation fails. Second possible cause of the error is the register file unit. Third possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the data cache load word operation with clean MISS fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity error generator on byte zero fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity error generator on byte one fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity error generator on byte two fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity error generator on byte three fails. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

0F
MESSAGE

No message. System halts. (E)

CAUSE

cache diagnostic register bit is stuck.

ACTION

Remove floating-point board, then reboot the system. Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying data path on the instruction cache. Second possible cause of error is the execution unit..

ACTION

Contact your Hewlett-Packard Support Representative.

15
MESSAGE

No message. System halts. (E)

CAUSE

Size of I_CA and D_CA do not match (check revision of execution unit.) Second possible cause of the error is the execution unit.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

Cache line gets updated on data TLB MISS fault.

ACTION

Contact your Hewlett-Packard Support Representative.

17
MESSAGE

No message. System halts. (E)

CAUSE

Memory line gets updated on data TLB MISS fault.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying byte transaction with data cache MISS.

ACTION

Contact your Hewlett-Packard Support Representative.

19
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying half word transaction with data cache MISS.

ACTION

Contact your Hewlett-Packard Support Representative.

1A
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying parity checking/generator with EIRR/CMD.

ACTION

Contact your Hewlett-Packard Support Representative.

1B
MESSAGE

No message. System halts. (E)

CAUSE

cache line gets updated on TLB data trap.

ACTION

Contact your Hewlett-Packard Support Representative.

1C
MESSAGE

No message. System halts. (E)

CAUSE

memory gets updated on TLB data trap.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying cache tag parity error.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying EIRR/CMD with its address.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying soft reset with its address.

ACTION

Contact your Hewlett-Packard Support Representative.

23
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying operation of LDCWS instruction.

ACTION

Contact your Hewlett-Packard Support Representative.

24
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying semaphore in load word and clear.

ACTION

Contact your Hewlett-Packard Support Representative.

25
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying operation of cache MISS.

ACTION

Contact your Hewlett-Packard Support Representative.

26
MESSAGE

No message. System halts. (E)

CAUSE

Failure while verifying operation of cache FREZ.

ACTION

Contact your Hewlett-Packard Support Representative.

C7
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM7 U1301.

ACTION

Remove Floating-Point board then reboot the system. Contact your Hewlett-Packard Support Representative.

CA
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs during a series of arbitrary microcode calculations. Areas of possible cause are the mapper PROM or the math chips.

ACTION

Remove floating-point board then reboot the system. Contact your Hewlett-Packard Support Representative.

CC
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs which slows the execution of the floating-point unit.

ACTION

Remove floating-point board, then reboot the system. Contact your Hewlett-Packard Support Representative.

Class Error 3: System Monitor Card Failure

System monitor card messages take the form:

  • 30xx

where:

  • xx = detailed error number.

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

data error occurs while verifying byte 10c (hex) of nonvolatile memory (NVM).

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

General register 0 is not zero at transfer of control (TOC).

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Invalid return address received for TOC. Second possible cause of the error is memory.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify processor dependent code (PDC) PROM. No PDC PROM installed.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Cannot find second part of self-test in PDC PROM. PDC PROM not installed.

ACTION

Contact your Hewlett-Packard Support Representative.

09
MESSAGE

No message. System halts. (E)

CAUSE

Cannot find PDC code in PDC PROM.

ACTION

check PDC PROM. Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Cannot initialize memory with switch 3 open.

ACTION

Try booting with switch 3 in normal position. Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

General register 0 is not found to be zero at TOC or HPMC save state routine.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error message occurs for HPMC in HPMC save state routine.

ACTION

Contact your Hewlett-Packard Support Representative.

0D
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify checksum while downloading code from EPROM on system monitor card.

ACTION

Contact your Hewlett-Packard Support Representative.

0E
MESSAGE

No message. System boots. (W)

CAUSE

Self-test completes with warning.

ACTION

check warning message(s). Contact your HP Representative if future problem occurs.

0F
MESSAGE

No message. System boots. (I)

CAUSE

Self-test completes successfully.

21
MESSAGE

No message. Self-test continues. (W)

CAUSE

Verification of stable storage fails.

ACTION

Contact your HP Representative if system halt occurs or future problem encountered.

22
MESSAGE

No message. Self-test continues. (W)

CAUSE

Failure occurs while reading from stable storage.

ACTION

Contact your HP Support Representative if system halt occurs or future problem encountered.

28
MESSAGE

No message. Self-test continues. (W)

CAUSE

Failure occurs while reading from time-of-day clock.

ACTION

Contact your HP Support Representative if system halt occurs or future problem encountered. check time-of-day entry during START routine.

Class Error 4: Coprocessor Failure

Coprocessor messages take the form:

  • 42xx

where:

  • xx = the last two digits of the hex display.

00
MESSAGE

No message. System halts. (E)

CAUSE

Error indicates that the coprocessor is frozen.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

02
MESSAGE

No message. System halts. (E)

CAUSE

Test fails as single load followed by a single store is executed without an intervening I-cache miss.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

03
MESSAGE

No message. System halts. (E)

CAUSE

Test fails as double load followed by a double store is executed to see that the lower word returns correctly.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

04
MESSAGE

No message. System halts. (E)

CAUSE

Test fails as floating-point operation is executed and followed by a sufficient number of nonfloating-point instructions to ensure that the FP operation has been completed. A single-precision store performs the check of the result.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

05
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a floating-point compare operation that sets the C bit is executed. An FTEST instruction checks that the C bit has been set.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

06
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a load of the status register is attempted from an I/O address. This should abort.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

07
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a coprocessor load followed by a floating-point operation that uses the load data is executed.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

08
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs since a floating-point operation that causes a trapping exception is immediately followed by a coprocessor store with a T-register conflict. This store should have been delayed until the trap completes, reflecting the result of the trap.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

09
MESSAGE

No message. System halts. (E)

CAUSE

An unanticipated trap occurs, possibly caused by a failure of the r1 comparator or trap logic.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Test of conflict comparator fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0B
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as coprocessor load of a nonzero number to FPR (0), the status register, is executed and then a floating-point operation that requires zero as an operand is executed. This tests that the FP operation reflects an operand of zero.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0C
MESSAGE

No message. System halts. (E)

CAUSE

T-bit of FPR(0) is not set.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0D
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a floating-point operation with a zero T-field is executed followed by a coprocessor store of the status register. The status register should not have been affected by the FP operation.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0E
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a coprocessor load to a reserved register is attempted. This should cause a reserved operation trap.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

0F
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs as a coprocessor load from an I/O address is attempted. This load should abort.

ACTION

Contact your Hewlett-Packard Support Representative.

31
MESSAGE

No message. System halts. (E)

CAUSE

Test results in an unexpected assist exception trap. This cause can stem from a variety of problems in the system, possibly resulting from a test of the conflict comparator. This test can also reflect a malfunction of one or more of the math chips.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

42
MESSAGE

No message. System halts. (E)

CAUSE

Test of ALUZERO condition fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

43
MESSAGE

No message. System halts. (E)

CAUSE

Test of ALUZERO condition fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

44
MESSAGE

No message. System halts. (E)

CAUSE

Test of ALUSIGN condition fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

45
MESSAGE

No message. System halts. (E)

CAUSE

Test of XOR in ALU fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

46
MESSAGE

No message. System halts. (E)

CAUSE

Test of AND in ALU fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

47
MESSAGE

No message. System halts. (E)

CAUSE

Test of OR in ALU fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

48
MESSAGE

No message. System halts. (E)

CAUSE

Test of load to status register fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

49
MESSAGE

No message. System halts. (E)

CAUSE

Test of instruction register fails.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

62
MESSAGE

No message. System halts. (E)

CAUSE

Detect failure of multiply chip U2302.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

64
MESSAGE

No message. System halts. (E)

CAUSE

Detect failure of add chip U2104.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

65
MESSAGE

No message. System halts. (E)

CAUSE

Detect failure of divide chip U2305.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

80
MESSAGE

No message. System halts. (E)

CAUSE

Detect failure in nullify generation circuitry.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

86
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM6 U1101.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

90
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM7 U1301.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

91
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM2 U1302.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

95
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM5 U1401.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

96
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM1 U1402.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

97
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM4 U1403.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

98
MESSAGE

No message. System halts. (E)

CAUSE

Microcode detects possible failure of RAM0 U1404.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C0
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM0 U1404.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C1
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM1 U1402.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C2
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM2 U1302.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C3
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM3 U1303.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C4
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM4 U1403.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C5
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM5 U1401.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C6
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM6 U1101.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

C7
MESSAGE

No message. System halts. (E)

CAUSE

Macrocode detects possible failure of RAM7 U1301.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

CA
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs during a series of arbitrary microcode calculations. Areas of possible cause are the mapper PROM or the math chips.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

CC
MESSAGE

No message. System halts. (E)

CAUSE

An error occurs which slows the execution of the floating-point unit.

ACTION

Contact your Hewlett-Packard Support Representative. Remove the floating-point board, then reboot the system.

Class Error 5: Bus Protocol Failure

Bus protocol messages takes the form:

  • 5sxx

where:

  • s = slot number

  • xx = detailed error number.

00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of this test.

ACTION

Contact your Hewlett-Packard Support Representative.

Class Error 7: Memory Failure

Class Error 7

memory error messages takes the form:

  • 7sxx

where:

  • s = slot number

  • xx = detailed error number.

NOTE: The memory test takes about 1.5 seconds per MB of memory.
00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Either stuck bit occurs in I/O status register or cannot find four contiguous words within the first 256 KB without a single bit error.

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the memory with its address fails. Second possible cause of the error is the cache unit. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing memory fails. Second possible cause of the error is the cache unit. Third possible cause of the error is the TLB.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Multiple bit error flag is set by single bit error. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Multiple bit error flag is not set by multiple bit error. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

06
MESSAGE

No message. System halts. (E)

CAUSE

Memory controller cannot calculate the address of the faulty memory. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Single bit error is detected. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Parity checking/generator is not working. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of read/write protocol fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

0C
MESSAGE

No message. System halts. (E)

CAUSE

Verification of read and Clear protocol fails. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Undefined type of memory controller is found.

ACTION

Contact your Hewlett-Packard Support Representative.

11
MESSAGE

No message. System halts. (E)

CAUSE

Error occurs as "hole" in memory is detected.

ACTION

Install 32 MB memory controller. Contact your Hewlett-Packard Support Representative.

12
MESSAGE

No message. System halts. (E)

CAUSE

Last memory controller does not have a memory array installed.

ACTION

Contact your Hewlett-Packard Support Representative. Install memory array.

13
MESSAGE

No message. System halts. (E)

CAUSE

Last 8 MB (3 MB MC and 5 MB MA) memory controller does not have a memory array installed.

ACTION

Contact your Hewlett-Packard Support Representative. Install memory array.

2F
MESSAGE

No message. System halts. (E)

CAUSE

No memory board is found during initialization. Second possible cause of the error is the cache unit.

ACTION

Contact your Hewlett-Packard Support Representative.

Class Error 8: Channel Adapter Test

Channel adapter test messages take the form:

  • 8sxx

where:

  • s = slot number

  • xx = detailed error number.

NOTE: The channel adapter test takes about 5 seconds to perform.
00
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs at the start of the test of this board.

ACTION

Contact your Hewlett-Packard Support Representative.

01
MESSAGE

No message. System halts. (E)

CAUSE

Cannot enable soft physical address. (Cannot set the SSET bit.)

ACTION

Contact your Hewlett-Packard Support Representative.

02
MESSAGE

No message. System halts. (E)

CAUSE

Cannot disable soft physical address. (Cannot reset SSET bit to zero.)

ACTION

Contact your Hewlett-Packard Support Representative.

03
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify memory with its address.

ACTION

Contact your Hewlett-Packard Support Representative.

04
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify memory with sliding ones.

ACTION

Contact your Hewlett-Packard Support Representative.

05
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify memory with sliding zeros.

ACTION

Contact your Hewlett-Packard Support Representative.

06
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify memory with all zeros.

ACTION

Contact your Hewlett-Packard Support Representative.

07
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing of external interrupt enable mask register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

08
MESSAGE

No message. System halts. (E)

CAUSE

Cannot set interrupt register to zero.

ACTION

Contact your Hewlett-Packard Support Representative.

09
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing of interrupt register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0A
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing of chain RAM base register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0B
MESSAGE

No message. System halts. (E)

CAUSE

Failure encountered while pattern testing mask register.

ACTION

Contact your Hewlett-Packard Support Representative.

0E
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing of reset address register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

0F
MESSAGE

No message. System halts. (E)

CAUSE

Pattern testing of reset data register fails.

ACTION

Contact your Hewlett-Packard Support Representative.

10
MESSAGE

No message. System halts. (E)

CAUSE

Reset does not clear soft physical address (SPA).

ACTION

Contact your Hewlett-Packard Support Representative.

11
MESSAGE

No message. System halts. (E)

CAUSE

Either a channel I/O card is not installed, or none of the CIO cards pass the self-test and are ready for command.

ACTION

Contact your Hewlett-Packard Support Representative.

12
MESSAGE

No message. System halts. (E)

CAUSE

Stop command does not set the ready (RDY) bit.

ACTION

Contact your Hewlett-Packard Support Representative.

13
MESSAGE

No message. System halts. (E)

CAUSE

Chain command does not clear the RDY bit.

ACTION

Contact your Hewlett-Packard Support Representative.

14
MESSAGE

No message. System halts. (E)

CAUSE

Cannot get an interrupt at the end of DMA. (Appropriate bit in submask register not set.)

ACTION

Contact your Hewlett-Packard Support Representative.

15
MESSAGE

No message. System halts. (E)

CAUSE

DMA does not transfer data.

ACTION

Contact your Hewlett-Packard Support Representative.

16
MESSAGE

No message. System halts. (E)

CAUSE

RDY bit is not set at the end of DMA.

ACTION

Contact your Hewlett-Packard Support Representative.

17
MESSAGE

No message. System halts. (E)

CAUSE

CIO card returns wrong status after the subchannel is disconnected.

ACTION

Contact your Hewlett-Packard Support Representative.

18
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs with a CIO card. RFC, PST, PRE, or LVI do not match.

ACTION

Contact your Hewlett-Packard Support Representative.

1A
MESSAGE

No message. System halts. (E)

CAUSE

Hewlett-Packard IB loopback test reports data write status error.

ACTION

Contact your Hewlett-Packard Support Representative.

1B
MESSAGE

No message. System halts. (E)

CAUSE

Hewlett-Packard IB cannot get ready for command.

ACTION

Contact your Hewlett-Packard Support Representative.

1C
MESSAGE

No message. System halts. (E)

CAUSE

Hewlett-Packard IB loopback test reports undefined status error.

ACTION

Contact your Hewlett-Packard Support Representative.

1D
MESSAGE

No message. System halts. (E)

CAUSE

Hewlett-Packard IB loopback test reports data error.

ACTION

Contact your Hewlett-Packard Support Representative.

1E
MESSAGE

No message. System halts. (E)

CAUSE

Channel does not request attention after disconnecting the subchannel.

ACTION

Contact your Hewlett-Packard Support Representative.

20
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify link to previous link status block.

ACTION

Contact your Hewlett-Packard Support Representative.

21
MESSAGE

No message. System halts. (E)

CAUSE

Status error occurs while verifying link status quad.

ACTION

Contact your Hewlett-Packard Support Representative.

22
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify link to last data quad.

ACTION

Contact your Hewlett-Packard Support Representative.

23
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify counter within the DMA chain quad.

ACTION

Contact your Hewlett-Packard Support Representative.

25
MESSAGE

No message. System halts. (E)

CAUSE

Verification of channel with semaphore set to zero operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

26
MESSAGE

No message. System halts. (E)

CAUSE

Undefined error occurs. Cannot find any installed memory board.

ACTION

Contact your Hewlett-Packard Support Representative.

27
MESSAGE

No message. System halts. (E)

CAUSE

Verification of channel with semaphore fails. Semaphore changes from zero to one.

ACTION

Contact your Hewlett-Packard Support Representative.

28
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the parity checking operation fails.

ACTION

Contact your Hewlett-Packard Support Representative.

29
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the ME bit functionality on channel adapter status register for data parity errors fails. Channel does not set ME bit on data parity error.

ACTION

Contact your Hewlett-Packard Support Representative.

2A
MESSAGE

No message. System halts. (E)

CAUSE

Channel cannot identify a data parity error. (Wrong MSTAT issued on error.)

ACTION

Contact your Hewlett-Packard Support Representative.

2B
MESSAGE

No message. System halts. (E)

CAUSE

Verification of the ME bit functionality on channel adapter status register for address parity errors fails. (Channel does not set ME bit on error.)

ACTION

Contact your Hewlett-Packard Support Representative.

2C
MESSAGE

No message. System halts. (E)

CAUSE

Channel cannot identify an address parity error.

ACTION

Contact your Hewlett-Packard Support Representative.

2F
MESSAGE

No message. System halts. (E)

CAUSE

A mid-bus I/O card is not found.

ACTION

Contact your Hewlett-Packard Support Representative.

40
MESSAGE

No message. System halts. (E)

CAUSE

Channel cannot finish logchannel transaction. There is no interrupt at the end of the transaction.

ACTION

Contact your Hewlett-Packard Support Representative.

41
MESSAGE

No message. System halts. (E)

CAUSE

Logchannel status error occurs. The transaction requires the device adapter to be the system controller, and it is not.

ACTION

Check Hewlett-Packard IB card switch setting. Contact your Hewlett-Packard Support Representative.

42
MESSAGE

No message. System halts. (E)

CAUSE

Undefined logchannel status error occurs.

ACTION

Contact your Hewlett-Packard Support Representative.

43
MESSAGE

No message. System halts. (E)

CAUSE

End of the Hewlett-Packard IB loopback test with logchannel returns a bad status.

ACTION

Contact your Hewlett-Packard Support Representative.

44
MESSAGE

No message. System halts. (E)

CAUSE

Subchannel is not readied after the logchannel operation.

ACTION

Contact your Hewlett-Packard Support Representative.

45
MESSAGE

No message. System halts. (E)

CAUSE

Subchannel is not readied after attention request enable followed by an attention request operation.

ACTION

Contact your Hewlett-Packard Support Representative.

46
MESSAGE

No message. System halts. (E)

CAUSE

I/O card returns wrong status after an attention request.

ACTION

Contact your Hewlett-Packard Support Representative.

47
MESSAGE

No message. System halts. (E)

CAUSE

Correct bit is not set in the attention request register.

ACTION

Contact your Hewlett-Packard Support Representative.

48
MESSAGE

No message. System halts. (E)

CAUSE

Attention request bit set prior to attention request test. (Error unknown.)

ACTION

Contact your Hewlett-Packard Support Representative.

49
MESSAGE

No message. System halts. (E)

CAUSE

Subchannel does not request attention after enabling attention request and request attention. (write control of ARE and RQA.)

ACTION

Contact your Hewlett-Packard Support Representative.

4F
MESSAGE

No message. Self-test continues. (W)

CAUSE

Channel cannot complete its test without a Hewlett-Packard IB card.

ACTION

check device adapters. Contact your Hewlett-Packard Support Representative if device problems occur.

50
MESSAGE

No message. System halts. (E)

CAUSE

Cannot verify I/O test checksum.

ACTION

Contact your Hewlett-Packard Support Representative.

Class Error 9: Console Path Test

Class Error 9

Console path related errors and/or channel I/O errors take the following multiplexed code form:

  • 01wx

  • 9yzz

where:

  • w = CIO slot number (<> C)

  • x = Device address (always 0 for the console)

  • y = CIO mid-bus slot number

  • zz = IODC driver error code 00 - 7F.

0100 9y80
MESSAGE

None.(I)

CAUSE

I/O dependent code (IODC) from channel I/O bus (CIO) in console path fails.

ACTION

None. If problem recurs or is suspected cause of a future system problem or failure, contact your Hewlett Packard Support Representative.

0100 9y88
MESSAGE

No message. System halts. (E)

CAUSE

No working console is found. Autoboot disabled.

ACTION

Connect console or replace existing console. Reboot system.

01C0 9yzz
MESSAGE

No message. Self-test continues. (W)

CAUSE

Access port self-test fails. "zz" = AP self-test code (00-7F).

ACTION

If AP not functional, reset the system from the front panel. If a soft reset/transfer of control is needed, set switch 3 on the system monitor card to the open position and reset the system from the front panel. If AP is functional and can reset the system, note the error as a possible console path or CIO bus problem should a future problem or system failure occur.

01C0 9yF0
MESSAGE

No message. Self-test continues. (W)

CAUSE

Access port read of the hexadecimal display fails.

ACTION

None. Note error should a future system problem occur.

01C0 9yFF
MESSAGE

No message. Self-test continues. (W)

CAUSE

No access port is found.

ACTION

If an access port exists and remains functional, note error should the problem cause a future problem or system failure. If AP is disabled or not functioning and you have reset the system from the front panel, ignore warning message.