MPE/iX Intrinsics Reference Manual: HP e3000 MPE/iX Computer Systems > Chapter 4 Command Definitions (ABORTSESS - FCLOSE)

CLEANUSL

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

 » Index

NM and CM callable.

Deletes all inactive entries from currently managed USL files and returns the file number of the new USL file. Therefore, you must test the condition code immediately upon return from the intrinsic. Unpredictable results occur if an error number is used as a file number.

NOTE: A USL contains CM object code and is meaningful in the CM program development process only.

Syntax

      I16              I16V       CA
filenum:=CLEANUSL(uslfnum,formaldesig);

Functional Return

filenum

16-bit signed integer (assigned functional return)

Returns the new file number, if no error occurs, or if an error occurs condition code returns CCL (1) and filenum returns one of the following:

VaIue

Meaning

0

Unexpected end-of-file (EOF) marker on either the old or the new USL file

1

Unexpected I/O error on either the old or the new USL file

7

Unable to open new USL file

12

Invalid USL file

Parameters

uslfnum

16-bit signed integer by value (required)

Returns the file number of the file.

formaldesig

character array (required)

Passes the name to be given to the cleaned file. The array must end with a blank. If it contains all blanks, it deletes the inactive entries.

Condition Codes

CCE (2)

Request granted. The new file number is returned to filenum.

CCG (0)

Not returned.

CCL (1)

Request denied. An error number is returned to filenum.

Related Information

Intrinsics

ADJUSTUSLF, EXPANDUSLF, INITUSLF

Manual

MPE Segmenter Reference Manual