| Back | TOC | docs.hp | |||||||||||
| 1.5 Required Components for 489183-B21 Interconnects with 4 Enclosures per Cabinet | |||||||||||||
| The following tables indicate the required number of components for 4 server blade enclosures per cabinet, depending on the total number of server blade enclosures and type of Voltaire interconnect. For your interconnect and server blade configuration, see Section 1.1 to determine the potential bandwidth. | |||||||||||||
| Table 1-4: 1-24 Single-Density Server Blade Enclosure Configurations Using Voltaire ISR 9024 Interconnects | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Optional 9024 Leaf Chasses to Support Control and Utility Nodes | Number of 9024 Spine Chasses | Total Number of 9024 Interconnect Chasses | Maximum Number of 4X Link Cables | ||||||||
| 1 - 3 | 0-24 | 2 | 2 | 2 | 48 | ||||||||
| 4 - 6 | 0-24 | 2 | 4 | 4 | 96 | ||||||||
| 7 - 9 | 0-24 | 2 | 8 | 8 | 192 | ||||||||
| 10 - 12 | 0-24 | 2 | 8 | 8 | 192 | ||||||||
| 13 - 24 | 0-24 | 2 | 16 | 16 | 384 | ||||||||
| Table 1-5: 1-12 Double-Density Server Blade Enclosure Configurations Using Voltaire ISR 9024 Interconnects | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Optional 9024 Leaf Chasses to Support Control and Utility Nodes | Number of 9024 Spine Chasses | Total Number of 9024 Interconnect Chasses | Maximum Number of 4X Link Cables | ||||||||
| 1 - 3 | 0-24 | 2 | 4 | 4 | 96 | ||||||||
| 4 - 6 | 0-24 | 2 | 8 | 8 | 192 | ||||||||
| 7-12 | 0-24 | 2 | 16 | 16 | 384 | ||||||||
| Table 1-7: 19-36 Single-Density Server Blade Enclosure Configurations Using Voltaire ISR 2012 Interconnects | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9288 Chasses | Total Number of Power Supplies | Number of Fabric Boards | Number of 24-Port 4X Interconnect Cards | Maximum Number of 4X Link Cables | Optional 9024 Leaf Chasses to Support Control and Utility Nodes | ||||||
| 19 - 21 | 0-24 | 2 | 6 | 8 | 14 | 336 | 2 | ||||||
| 22 - 25 | 0-24 | 2 | 8 | 8 | 16 | 384 | 2 | ||||||
| 26 - 28 | 0-24 | 2 | 8 | 8 | 18 | 432 | 2 | ||||||
| 29 - 31 | 0-24 | 2 | 8 | 8 | 20 | 480 | 2 | ||||||
| 32 - 34 | 0-24 | 2 | 10 | 8 | 22 | 528 | 2 | ||||||
| 35 - 38 | 0-24 | 2 | 10 | 8 | 24 | 576 | 2 | ||||||
| Table 1-8: 10-18 Double-Density Server Blade Enclosure Configurations Using Voltaire ISR 2012 Interconnects | |||||||||||||
| Server Blade Enclosures | Control and Utility Nodes | Number of Managed 9288 Chasses | Total Number of Power Supplies | Number of Fabric Boards | Number of 24-Port 4X Interconnect Cards | Maximum Number of 4X Link Cables | Optional 9024 Leaf Chasses to Support Control and Utility Nodes | ||||||
| 10-12 | 0-24 | 2 | 8 | 8 | 16 | 384 | 2 | ||||||
| 13-15 | 0-24 | 2 | 8 | 8 | 20 | 480 | 2 | ||||||
| 16-18 | 0-24 | 2 | 10 | 8 | 24 | 576 | 2 | ||||||