Some systems may need a firmware upgrade prior to updating
to HP-UX 11i: Workstations: J-Class: J5000, J5600, J6000, J7000
If you are about
to install or upgrade one of the systems listed above, verify that
it has the minimum required firmware version. If needed, install
the patches for your system listed here in the following tables. If the needed firmware version or later is already on your
system, proceed to “PCI Adapter Requirements”.
If not, or if you do not know what firmware version is on your system,
please read on. Table 3-2 Minimum Firmware Versions for HP-UX 11i[1] Model or Bezel
| Firmware and Patch for HP-UX 11i Support |
|---|
Firmware Version | Minimum Available Patches |
|---|
HP-UX 11.0/11i | Tape Patch Name |
|---|
A-Class | 41.18 | PHSS_25314 PHSS_25315 | PF_CCRW4118 | B-Class, C-Class, J-Class[1] | 5.0 | PHSS_25982 PHSS_25983 | PF_CBCJ0050 | C3650, C3700, C3750, J6700, J6750 | 1.9 | n/a | n/a | L1000, L2000, rp5400, rp5450 | 41.38 | PHSS_25105 PHSS_25106 | PF_CRHW4138 | L3000 Rev A. | 40.43 | All Firmware | n/a | L1500, L3000, rp5430, rp5470 | 41.36 | All Firmware | PF_CMAW4136 | N4000, rp7400 | 41.02 | PHSS_22657 PHSS_22658 | PF_CPRW4102 |
Table 3-3 Older Workstation Firmware Requirements Model or Bezel | Firmware Version | 32/64 bit | Tape Patch Name[1] |
|---|
B132L, B132L+, B160, B180 | 6.1 | 32-bit | PF_CB1X0061 | B2600[2] | 1.4 | 64-bit | PF_CB260014 | | B[12]000, C3X00, J[567]X00[2] | 5.0 | 64-bit | PF_CBCJ0050 | | C160L | 5.8 | 32-bit | PF_CB1X0058 | | C160, C180 | 6.1 | 32 and 64-bit | PF_CC2X0061 | C200, C240 | 6.3 | 32 and 64-bit | PF_CC2X0063 | | J280, J282 | 2.5 (updated) | 32 and 64-bit | PF_CJ28X025 |
Table 3-4 Minimum Firmware Versions for OL* Support Model or Bezel | Firmware and Patch for OL*[1] Support |
|---|
Firmware Version | Minimum Current Patches |
|---|
HP-UX 11.0/11i | Tape Patch Name |
|---|
A-Class (A400, A500) | (OL* not available on A-Class) | B-Class, C-Class, J-Class | (Also, OL* not available
on workstations.) | L1000, L2000, rp5400, rp5450 | 41.39 | PHSS_25684 PHSS_25685 | PF_CRHW4139 | L3000 Rev A. | 41.46 | PHSS_25686 PHSS_25687 | | L1500, L3000, rp5430, rp5470 | 42.19 | PHSS_25686 PHSS_25687 | PF_CCAW4219 | N4000, rp7400 | 42.06 | PHSS_22688 PHSS_25931 | PF_CPIW4206 | rp7410 | Firmware Version 4.0 | PDC rev. 16.009 | PF_CRP74100400 | rp8400 | Firmware Version 4.0 | PDC rev. 16.009 | PF_CRF84000400 |
Current
System Firmware Versions and Patches |  |
In addition to verifying that your system meets the minimum requirements
to support HP-UX 11i in Table 3-2 “Minimum Firmware Versions for HP-UX 11i”,
the following table describes the latest recommended firmware versions
available for your system. These patches contain additional enhancements
and fixes to your system and also support HP-UX 11i functionality. Table 3-5 Current System Firmware Versions and Patches Model or Bezel
| Current Firmware Version
and Patch Support |
|---|
Latest Firmware Version | Available Patches |
|---|
SD-UX Patch Name HP-UX 11i
/11.0 | Tape Patch Name |
|---|
| B1000, B2000, J5x00, J6x00 | 5.0 | PHSS_25982 PHSS_25983 | PF_CBCJ0050 | C3650, C3700, C3750, J6700, J6750 | 1.9 | n/a | n/a | | B2600 Workstation | 1.4 | PHSS_26926 PHSS_26927 | PF_CB260014 | A400, A500, rp24xx | 42.19[1] | PHSS_27383 PHSS_27384 | PF_CHAW4219 | L1000, L2000, rp5400, rp5450 | 41.39 | PHSS_25684 PHSS_25685 | PF_CRHW4139 | L1500, L3000, rp5430, rp5470 | 42.19[2] | PHSS_27466 PHSS_27467 | PF_CARIW4219 | rp7410 | 4.0[3],[4] | n/a | PF_CRP74100400 | S16K-A, rp8400 | 4.0[3],[4] | n/a | PF_CRP84000400 |
How to
Verify Your Firmware Version |  |
Checking
Workstation Firmware VersionFollow these steps to check workstation firmware version prior
to migrating to HP-UX 11i: As root, shut down the system: Enter: shutdown -h Switch the system OFF.
Switch the system ON and watch console messages. Press
any key when prompted to cancel the automatic boot feature. Check the firmware version displayed at the beginning
of the boot process. If the firmware version for your B-, C- or
J-Class workstation is less than 2.3, it needs upgrading. Continue
with “How
to Download Firmware Upgrades”.
Checking
Server Firmware VersionThere are two methods to check firmware version on HP servers: OnlineDiagnostics
or the boot display. Use OnlineDiagnostics if you do not want to
reboot your system. If the OnlineDiagnostics are not already on your system, you
can find them on the HP-UX 11i Support Plus CD, OE DVD1, or on OE
CD2. As root, run the Support Tools Manager (STM)
utility: /usr/sbin/cstm Use the map command to find the device number (Dev Num)
for the processors on your system; search for items with the product
description CPU: cstm>map systemA.hp.comDev Num Path Product === ==================== ========================= 1 system system () ... 34 160 CPU (5c4) 35 166 CPU (5c4)
|
Select any one of the processors (CPU)
to use in the next step. Use the CPU device number as input to the sel dev command to request information on that processor. For
example: cstm>sel dev 34; info -- Updating Map -- Updating Map...
|
Use the information log command (il) to find the firmware version number: cstm>il -- Converting a (5060) byte raw log file to text. -- ... (output lines are omitted) |
-- Information Tool Log for CPU on path 160 -- Log creation time: Wed May 10 10:21:53 2000 Hardware path: 160 ...(output lines are omitted) Firmware Revision: 40.14 |
Enter q to leave this screen. Then press Enter at the next prompt, and enter exit to exit the utility.
If your system requires a firmware
upgrade, proceed to “How
to Download Firmware Upgrades”
Using the Boot Display
(this requires a reboot):As your system is booting up, interrupt the
auto-boot sequence by pressing any key when prompted. For example: ... Primary boot path: 0/0/2/0.2 Alternate boot path: 0/0/2/0.2 Console path: 0/0/4/0.0 Keyboard path: 0/0/4/0.0 Processor is booting from first available device. To discontinue, press any key with 10 seconds. |
You'll see the boot Main Menu: ---Main Menu-------------------------------------------------- Command Description ------------ -------------- BOot [PRI|ALT|<path>] Boot from specified path PAth [PRI|ALT] [<path>] Display or modify a path SEArch [DIsplay|IPL] [<path>] Search for boot devices COnfiguration menu Displays or sets boot values INformation menu Displays hardware information ... HElp [<menu>|<command>] Display help for menu or command RESET Restart the system Main Menu: Enter command or menu> |
Enter: IN (for INformation)
You'll see the information menu: ---Information Menu------------------------------------------- Command Description ------------ -------------- ALL Display all system information BootINfo Display boot-related information Cache Display cache information ChipRevisions Display revisions of major VLSI FRU Display FRU information FwrVersion Display firmware information ... Main Return to Main Menu Information Menu: Enter command> |
Enter: FV (for Firmware Version) You'll see something like the following: FIRMWARE INFORMATION Firmware Version: 40.14
|
Continue with the boot (example commands are in bold): Information Menu: Enter command > BO PRI Interact with IPL (Y, N, or Cancel)?> N Booting...
|
If your system requires a a firmware
upgrade, proceed to “How
to Download Firmware Upgrades”
How
to Download Firmware Upgrades |  |
To get a firmware patch over the Web: Go to this web site: http://itrc.hp.com/ From the home page, select individual patches. If you are already registered, log in with your user
ID and password. If not registered, following the instructions on
the screen. Remember to save your user ID and password. From the patch database main page, select hp-ux. Select Series 700 for workstations or Series 800 for servers. Select the OS your system is running,
either 10.20 or 11.00. Choose Search By Keyword, enter the patch name for your system listed on Table 3-1 “Supported Systems” and click search. The patch you entered or its successor should be listed. Select
that patch (click select all, then add to selected patch list, then download). Ignore any comments that the firmware patch is "Not
yet HP recommended". After downloading the patch, proceed to “How
to Apply Firmware Patches”.
How
to Apply Firmware Patches |  |
Follow these steps to install each patch you've downloaded
on each system prior to updating it to HP-UX 11i: Back up your system! Log in as root. Copy the patches to the /tmp directory. Change your working directory to /tmp and extract each patch using the sh command. For example, to extract patch PHSS_23184: cd /tmp sh PHSS_23184 Run swinstall to install each patch. For example: /usr/sbin/swinstall -x autoreboot=true -x \ patch_match_target=true -s /tmp/PHSS_23184.depot
 |  |  |  |  | CAUTION: Do not interrupt the update
process. Do not power down the system or resume similar
actions during the update. The process requires multiple reboots.
Once the system has rebooted HP-UX completely, it is safe to perform
any other normal operation. |  |  |  |  |
|