| United States-English |
|
|
|
![]() |
HP-UX 11i December 2003 Release Notes: HP-UX Servers and Workstations > Chapter 4 nPartition (Hard
Partition) SystemsNew Attention Indicator Behavior |
|
updated for |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Attention LED State | Meaning |
|---|---|
OFF | Normal; not selected, normal operation. |
ON | Attention; operational problem. Supported for PCI card slot LEDs only. Service is required; problems have been identified with the component. |
BLINKING | Locate; user requested to locate hardware. User has selected the hardware for use in a service operation. |
These changes affect all current HP hard-partitionable servers and will be implemented for all future HP hard-partitionable servers, as well. (Note that only Superdome servers were supported by HP-UX releases with the old behavior.)
However, it wasn’t until the HP-UX 11i June 2001 release that SAM and Partition Manager started to blink PCI slot attention indicators during tasks involving PCI cards or card slots. As a result, sites that have HP Superdome servers running both the original HP-UX 11i release and the HP-UX 11i June 2001 (or later) release can have attention indicators at different states (steady-on and blinking).
| NOTE: These changes do not affect the behavior of the HP rp7410, rp8400
or HP Superdome cabinet “attention” lights, which
are not user-controllable. These changes also do not affect HP Superdome cabinet number LCD behavior. | |
Details about how the new fruled and Partition Manager affect cell and I/O chassis attention indicators are provided in the fruled(1) manpage, the HP System Partitions Guide, and the Partition Manager online help.
The rad command, whose functionality has not changed, is documented in the rad(1M) manpage.
|
|||||||||||||||