Once the installation is complete, you must configure the HP Insight Management Agents. For configuration instructions, see Chapter 3.
The configuration values are stored in /etc/snmp/snmpd.conf. If you are familiar with manual configuration of SNMP agents, you can edit this file and restart the SNMP daemon.
To verify HP Insight Management agent status, enter /etc/init.d/hpima status, and then press Enter.
The following is an example of the output that is returned from this command:
hpimaX (pid 29032) is running...
hpimahostd (pid 29547) is running...
hpimathreshd (pid 29557) is running...
hpimahealthd (pid 29570) is running...
hpimastdeqd (pid 29580) is running...
hpimaeventd (pid 29590) is running...
hpimaidad (pid 29608) is running...
hpimasasd (pid 29619) is running...
hpimascsid (pid 29631) is running...
hpimafcad (pid 29643) is running...
hpimanicd (pid 29661) is running...
hpimaE0traps (pid 29675) is running...
|