Use one or more of the following grounding methods when handling or installing electrostatic-sensitive parts:

  • A wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.

  • Heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools.

  • A portable field service kit with a folding static-dissipating work mat.