After the system reboots, verify that the installation was successful by following these steps:

  1. Enter the swlist  command:

    # swlist

    If the Smart Array Controller is installed correctly, the generated output looks similar to the following examples:

    For HP-UX 11i v3:

    RAID-01 B.11.31.0709.01   RAID SA; Supptd HW=A7143A/A9890A/A9891A
    

    For HP-UX 11i v2:

    RAID-01 B.11.23.0706   RAID SA; Supptd HW=A7143A/A9890A/A9891A
    

    The version string that appears indicates the version of the RAID-01 bundle installed on your server.

  2. Enter the ioscan -kfnd ciss command:

    # ioscan -kfnd ciss

    If the Smart Array Controller software is installed correctly, the generated output looks similar to this:

    # ioscan -kfnd ciss
    Class     I  H/W Path       Driver   S/W State   H/W Type     Description
    ==========================================================================
    ext_bus   5  0/6/0/0/0/0/1/0/0/0  ciss     CLAIMED     INTERFACE    PCIe SAS SmartArray P400 RAID Controller
                               /dev/ciss5

    If the software is not installed correctly, reinstall it using swinstall. See “Installing Software”.