Use the sautil command to confirm and update the firmware version on each physical disk in the SmartArray disk enclosure attached to the Smart Array Controller.
You must log in as a superuser to run the sautil command.
Before running the sautil command to confirm or update physical disk firmware, you must know the device file name for the Smart Array Controller and the SCSI channel and SCSI ID for each physical disk attached to the Smart Array Controller.
Determining the Smart Array Series Controller Device File |
 |
Determine the device file name for the Smart Array Controller from the output of the ioscan -kfnd ciss command. An example of the ioscan output listing the Smart Array Controller device files follows.
# ioscan -kfnd ciss
Class I H/W Path Driver S/W State H/W Type Description
==========================================================================
ext_bus 5 0/6/0/0/0/0/1/0/0/0 ciss CLAIMED INTERFACE PCIe SAS SmartArray P400 RAID Controller
/dev/ciss5 |
In the example, /dev/ciss5 is the device file for the Smart Array P400 Controller.
Determining the Connector/Enclosure/Bay and Firmware Version for Physical Disks |
 |
You can determine the Connector/Enclosure/Bay and current firmware version for each physical disk attached to the Smart Array Controller by using the sautil <device_file> command (extensive output), or the sautil <device_file> -s command (shortened output).
The sautil <device_file> -s command displays an abbreviated list of information for the Smart Array Controller and connected devices, including a SAS/SATA DEVICE SUMMARY that lists the Connector/Enclosure/Bay for each physical disk attached to the Smart Array Controller. The firmware version installed on each physical disk is also included in the sautil <device_file> -s command output. For example:
 |
# sautil /dev/ciss5 –s
******************************************************************************
**** ****
**** S A U T I L S u p p o r t U t i l i t y ****
**** ****
**** for the HP SmartArray RAID Controller Family ****
**** ****
**** version A.02.11 ****
**** ****
**** (C) Copyright 2003-2006 Hewlett-Packard Development Company, L.P. ****
******************************************************************************
---- DRIVER INFORMATION ------------------------------------------------------
Driver State........................ READY
---- CONTROLLER INFORMATION --------------------------------------------------
Controller Product Number........... P400
Controller Product Name............. HP PCIe SmartArray P400
Hardware Path....................... 0/6/0/0/0/0/1/0/0/0
Serial Number....................... PA5360BBFSW2ON
Device File......................... /dev/ciss5
Hardware Revision................... ‘B’
Firmware Revision (in ROM).......... 2.08
# of Logical Drives................. 1
# of Physical Disks Configured...... 6
# of Physical Disks Detected........ 8
---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------
Array Accelerator Board Present?.... yes
Cache Configuration Status.......... cache enabled
Cache Ratio......................... 50% Read / 50% Write
Total Cache Size (MB)............... 208
Battery Pack Count.................. 1
Battery Status (pack #1)............ ok
---- LOGICAL DRIVE SUMMARY ---------------------------------------------------
# RAID Size Status
0 ADG 15360 MB OK
---- SAS/SATA DEVICE SUMMARY -------------------------------------------------
Location Ct Enc Bay WWID Type Capacity Status
internal 1I 1 12 0x500000e01117c732 DISK 36.4 GB OK
internal 1I 1 11 0x500000e01115c352 DISK 36.4 GB OK
internal 1I 1 10 0x5000c5000032b839 DISK 36.4 GB OK
internal 1I 1 9 0x5000c5000030b0c5 DISK 36.4 GB OK
internal 2I 1 16 0x500000e011213482 DISK 36.4 GB OK
internal 2I 1 15 0x5000c500002084c9 DISK 73.4 GB OK
internal 2I 1 14 0x5000c5000030b9c9 DISK 36.4 GB UNASSIGNED
internal 2I 1 13 0x500000e01118a7a2 DISK 36.4 GB UNASSIGNED
---- SAS/SATA ENCLOSURE SUMMARY ----------------------------------------------
Location Ct Enc Expander_count Bay_count SEP_count
internal 1I 1 0 4 1
internal 2I 1 0 4 1
---- SAS/SATA DEVICE 1I:1:12:0x500000e01117c732 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 12
WWID............................................. 0x500000e01117c732
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55001SF0519
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 1I:1:11:0x500000e01115c352 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 11
WWID............................................. 0x500000e01115c352
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55001H70519
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 1I:1:10:0x5000c5000032b839 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 10
WWID............................................. 0x5000c5000032b839
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B53
Device Serial Number............................. 3LC03L7Z0000854051PK
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 1I:1:9:0x5000c5000030b0c5 [DISK] ------------------------
Connector Location............................... internal
Connector........................................ 1I
Enclosure........................................ 1
Bay.............................................. 9
WWID............................................. 0x5000c5000030b0c5
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B53
Device Serial Number............................. 3LC01ZT100008524EDM6
Device Firmware Version.......................... HPD3
---- SAS/SATA DEVICE 2I:1:16:0x500000e011213482 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 2I
Enclosure........................................ 1
Bay.............................................. 16
WWID............................................. 0x500000e011213482
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55003940521
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 2I:1:15:0x5000c500002084c9 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 2I
Enclosure........................................ 1
Bay.............................................. 15
WWID............................................. 0x5000c500002084c9
Device Type...................................... DISK
Disk Capacity.................................... 73.4 GB
Device Status.................................... OK
Device Vendor ID................................. HP
Device Product ID................................ DG072A8B54
Device Serial Number............................. 3LB02D5200008523E7Z1
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 2I:1:14:0x5000c5000030b9c9 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 2I
Enclosure........................................ 1
Bay.............................................. 14
WWID............................................. 0x5000c5000030b9c9
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... UNASSIGNED
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B53
Device Serial Number............................. 3LC01ZTE00008524EDPX
Device Firmware Version.......................... HPD4
---- SAS/SATA DEVICE 2I:1:13:0x500000e01118a7a2 [DISK] -----------------------
Connector Location............................... internal
Connector........................................ 2I
Enclosure........................................ 1
Bay.............................................. 13
WWID............................................. 0x500000e01118a7a2
Device Type...................................... DISK
Disk Capacity.................................... 36.4 GB
Device Status.................................... UNASSIGNED
Device Vendor ID................................. HP
Device Product ID................................ DG036A8B5B
Device Serial Number............................. B2G2P55001W50520
Device Firmware Version.......................... HPD4
******************************************************************************
**** End of SAUTIL Output ****
****************************************************************************** |
 |
In this example, the SAS/SATA DEVICE SUMMARY lists the Connector/Enclosure/Bay for each physical disk attached to the Smart Array Controller. The information provided for each of the physical disks, following the SAS/SATA DEVICE SUMMARY, indicates that all of the physical disks have firmware version HPD4 installed except for 1I:1:9, which has version HPD3.