HP Smart Array P800 Controller for Integrity Servers Installation Guide: HP-UX 11i v2 and 11i v3; OpenVMS 8.3 > Chapter 1 HP-UX Installation

Confirming and Updating Physical Disk Firmware

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

 » Index

Use the sautil command to confirm and update the firmware version on each physical disk in the SmartArray disk enclosure attached to the Smart Array Controller.

NOTE: This section of the HP Smart Array Support Guide focuses on the sautil command options used to confirm, or change, physical disk firmware. The other sautil command options listed in the sautil help screen and detailed in the sautil manpages are explained in the HP Smart Array P400 and P800 Controller for Integrity Servers Support Guide at:

http://docs.hp.com/en/netcom.html

You must log in as a superuser to run the sautil command.

Before running the sautil command to confirm or update physical disk firmware, you must know the device file name for the Smart Array Controller and the SCSI channel and SCSI ID for each physical disk attached to the Smart Array Controller.

Determining the Smart Array Series Controller Device File

Determine the device file name for the Smart Array Controller from the output of the  ioscan -kfnd ciss command. An example of the ioscan output listing the Smart Array Controller device files follows.

# ioscan -kfnd ciss
Class     I  H/W Path       Driver   S/W State   H/W Type     Description
==========================================================================
ext_bus   5  0/6/0/0/0/0/1/0/0/0  ciss     CLAIMED     INTERFACE    PCIe SAS SmartArray P400 RAID Controller
                           /dev/ciss5

In the example, /dev/ciss5 is the device file for the Smart Array P400 Controller.

Determining the Connector/Enclosure/Bay and Firmware Version for Physical Disks

You can determine the Connector/Enclosure/Bay and current firmware version for each physical disk attached to the Smart Array Controller by using the sautil <device_file> command (extensive output), or the sautil <device_file> -s command (shortened output).

The sautil <device_file> -s command displays an abbreviated list of information for the Smart Array Controller and connected devices, including a SAS/SATA DEVICE SUMMARY that lists the Connector/Enclosure/Bay for each physical disk attached to the Smart Array Controller. The firmware version installed on each physical disk is also included in the sautil <device_file> -s command output. For example:

# sautil /dev/ciss5 –s

******************************************************************************
****                                                                      ****
****             S A U T I L   S u p p o r t   U t i l i t y              ****
****                                                                      ****
****             for the HP SmartArray RAID Controller Family             ****
****                                                                      ****
****                           version A.02.11                            ****
****                                                                      ****
****  (C) Copyright 2003-2006 Hewlett-Packard Development Company, L.P.   ****
******************************************************************************



---- DRIVER INFORMATION ------------------------------------------------------

  Driver State........................ READY

---- CONTROLLER INFORMATION --------------------------------------------------

  Controller Product Number........... P400
  Controller Product Name............. HP PCIe SmartArray P400
  Hardware Path....................... 0/6/0/0/0/0/1/0/0/0
  Serial Number....................... PA5360BBFSW2ON
  Device File......................... /dev/ciss5
  Hardware Revision................... ‘B’
  Firmware Revision (in ROM).......... 2.08
  # of Logical Drives................. 1
  # of Physical Disks Configured...... 6
  # of Physical Disks Detected........ 8


---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------

  Array Accelerator Board Present?.... yes
  Cache Configuration Status.......... cache enabled
  Cache Ratio......................... 50% Read / 50% Write
  Total Cache Size (MB)............... 208
  Battery Pack Count.................. 1
  Battery Status (pack #1)............ ok


---- LOGICAL DRIVE SUMMARY ---------------------------------------------------

       #   RAID      Size        Status   

       0   ADG       15360 MB    OK        


---- SAS/SATA DEVICE SUMMARY -------------------------------------------------

  Location  Ct Enc Bay       WWID           Type        Capacity Status

  internal  1I   1  12  0x500000e01117c732  DISK        36.4 GB  OK        
  internal  1I   1  11  0x500000e01115c352  DISK        36.4 GB  OK        
  internal  1I   1  10  0x5000c5000032b839  DISK        36.4 GB  OK        
  internal  1I   1   9  0x5000c5000030b0c5  DISK        36.4 GB  OK        
  internal  2I   1  16  0x500000e011213482  DISK        36.4 GB  OK        
  internal  2I   1  15  0x5000c500002084c9  DISK        73.4 GB  OK        
  internal  2I   1  14  0x5000c5000030b9c9  DISK        36.4 GB  UNASSIGNED
  internal  2I   1  13  0x500000e01118a7a2  DISK        36.4 GB  UNASSIGNED


---- SAS/SATA ENCLOSURE SUMMARY ----------------------------------------------

  Location  Ct   Enc  Expander_count    Bay_count     SEP_count     

  internal  1I   1    0                 4             1              
  internal  2I   1    0                 4             1              
  

---- SAS/SATA DEVICE 1I:1:12:0x500000e01117c732 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 1I 
  Enclosure........................................ 1
  Bay.............................................. 12
  WWID............................................. 0x500000e01117c732  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B5B      
  Device Serial Number............................. B2G2P55001SF0519
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 1I:1:11:0x500000e01115c352 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 1I 
  Enclosure........................................ 1
  Bay.............................................. 11
  WWID............................................. 0x500000e01115c352  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B5B      
  Device Serial Number............................. B2G2P55001H70519
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 1I:1:10:0x5000c5000032b839 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 1I 
  Enclosure........................................ 1
  Bay.............................................. 10
  WWID............................................. 0x5000c5000032b839  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B53      
  Device Serial Number............................. 3LC03L7Z0000854051PK
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 1I:1:9:0x5000c5000030b0c5 [DISK] ------------------------

  Connector Location............................... internal  
  Connector........................................ 1I 
  Enclosure........................................ 1
  Bay.............................................. 9
  WWID............................................. 0x5000c5000030b0c5  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B53      
  Device Serial Number............................. 3LC01ZT100008524EDM6
  Device Firmware Version.......................... HPD3
  

---- SAS/SATA DEVICE 2I:1:16:0x500000e011213482 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 2I 
  Enclosure........................................ 1
  Bay.............................................. 16
  WWID............................................. 0x500000e011213482  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B5B      
  Device Serial Number............................. B2G2P55003940521
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 2I:1:15:0x5000c500002084c9 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 2I 
  Enclosure........................................ 1
  Bay.............................................. 15
  WWID............................................. 0x5000c500002084c9  
  Device Type...................................... DISK       
  Disk Capacity.................................... 73.4 GB  
  Device Status.................................... OK        
  Device Vendor ID................................. HP      
  Device Product ID................................ DG072A8B54      
  Device Serial Number............................. 3LB02D5200008523E7Z1
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 2I:1:14:0x5000c5000030b9c9 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 2I 
  Enclosure........................................ 1
  Bay.............................................. 14
  WWID............................................. 0x5000c5000030b9c9  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... UNASSIGNED
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B53      
  Device Serial Number............................. 3LC01ZTE00008524EDPX
  Device Firmware Version.......................... HPD4
  

---- SAS/SATA DEVICE 2I:1:13:0x500000e01118a7a2 [DISK] -----------------------

  Connector Location............................... internal  
  Connector........................................ 2I 
  Enclosure........................................ 1
  Bay.............................................. 13
  WWID............................................. 0x500000e01118a7a2  
  Device Type...................................... DISK       
  Disk Capacity.................................... 36.4 GB  
  Device Status.................................... UNASSIGNED
  Device Vendor ID................................. HP      
  Device Product ID................................ DG036A8B5B      
  Device Serial Number............................. B2G2P55001W50520
  Device Firmware Version.......................... HPD4

******************************************************************************
****                         End of SAUTIL Output                         ****
******************************************************************************

In this example, the SAS/SATA DEVICE SUMMARY lists the Connector/Enclosure/Bay for each physical disk attached to the Smart Array Controller. The information provided for each of the physical disks, following the SAS/SATA DEVICE SUMMARY, indicates that all of the physical disks have firmware version HPD4 installed except for 1I:1:9, which has version HPD3.