After the system reboots, verify that the installation was successful by following these steps: Boot OpenVMS and log in to a privileged account. Use the MSA Utility to verify that the controller is installed and operating. For example: $ RUN SYS$SYSTEM:MSA$UTIL
MSA> SET ADAPTER PKA0
MSA> SHOW ADAPTER
Adapter: _PKA0: (DEFAULT)
P800 (c) HP P98690D9SU80UT Software 4.12
SCSI_VERSION = No Conformance
Supported Redundancy Mode:
Current Redundancy mode: Not Available/Not currently redundant
Current Role: Standby
Cache:
114 megabyte read cache 342 megabyte write cache
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Battery is fully charged.
|
Use the MSA utility to configure and manage the Smart Array P800 controller. For more information about the MSA utility, see the OpenVMS Version 8.3-1H1 for Integrity Servers New Features and Release Notes at: http://h71000.www7.hp.com/doc/
|