1.4 Required Components for 1:1 Bandwidth with 4 Enclosures per Cabinet
Back
TOC
Table 1-4: 1-12 Enclosure Configurations Using Cisco 7000D interconnects: Full Bandwidth
Server Blade Enclosures Control + Utility Nodes 7000D Leaf Chasses (24*4X) 7000D Spine Chasses Total 7000D Switch Chasses Maximum Number of 4X Link Cables Minimum Number of Managed Switches
2 - 3 0-24 0 2 2 48 2
4 - 6 0-24 0 4 4 96 2
7 - 9 0-24 0 8 8 192 2
10 - 12 0-24 0 8 8 192 2
Table 1-5: 1-9 Enclosure Configurations Using Cisco 7012D Interconnects: Full Bandwidth
Servee Blade Enclosures Control + Utility Nodes Number of 7012D Chasses Number of Fabric Boards Number of 12-Port 4X Switch Cards Max Number of 4X Link Cables Optional 1 or 2 Extra 7000D to Provide Subnet Manager
2 - 3 0-24 1 3 4 48 2
4 - 6 0-24 1 3 8 96 2
7 - 9 0-24 1 3 12 144 2
Table 1-6: 1-18 Enclosure Configurations Using Cisco 7024D Interconnects: Full Bandwidth
Server Blade Enclosures Control + Utility Nodes Number of 7024D Chasses Number of Fabric Boards Number of 12-Port 4X Switch Cards Maximum Number of 4X Link Cables Optional 1 or 2 Extra 7000D to Provide Subnet Manager
1 - 3 0-24 1 6 4 48 2
4 - 6 0-24 1 6 8 96 2
7 - 9 0-24 1 6 12 144 2
10 - 12 0-24 1 6 16 192 2
13 - 15 0-24 1 6 20 240 2
16 - 18 0-24 1 6 24 288 2
Table 1-7: 19-36 Enclosure Configurations Using Cisco 7024D Interconnects: Full Bandwidth
Server Blade Enclosures Control + Utility Nodes Number of 7024 Chasses Number of Fabric Boards Number of 12-Port 4X Switch Cards Maximum Number of 4X Link Cables Optional 1 or 2 Extra 7000D to Provide Subnet Manager
19 - 21 0-24 2 12 28 336 2
22 - 24 0-24 2 12 32 384 2
25 - 27 0-24 2 12 36 432 2
28 - 30 0-24 2 12 40 480 2
31 - 33 0-24 2 12 44 528 2
33 - 36 0-24 2 12 48 576 2