Back TOC docs.hp
1.5 Required Components for One 410398-B21 Interconnect with 4 Enclosures per Cabinet
The following tables indicate the required number of components for 3 server blade enclosures per cabinet, depending on the total number of server blade enclosures and type of Voltaire interconnect. For your interconnect and server blade configuration, see Section 1.1 to determine the potential bandwidth. (Note: print this in landscape mode to view the complete page in hardcopy format.)
Table 1-4: 1-24 Enclosure Configurations Using ISR 9024 Interconnects
Server Blade Enclosures Control and Utility Nodes 9024 Leaf Chassis (24*4X) 9024 Spine Chassis Total Number of 9024 Interconnect Chasses Maximum Number of 4X Link Cables Minimum Number of Managed Switches
1 - 3 0-24 0 1 1 24 1
4 - 6 0-24 2 2 2 48 2
7 - 9 0-24 2 4 4 96 2
10 - 12 0-24 2 4 4 96 2
13 - 15 0-24 2 8 8 192 2
16 - 18 0-24 2 8 8 192 2
19 - 21 0-24 2 8 8 192 2
22 - 24 0-24 2 8 8 192 2
Table 1-5: 1-12 Enclosure Configurations Using ISR 2004 Interconnects
Server Blade Enclosures Control and Utility Nodes Number of Managed 9096 Chasses Total Number of Power Supplies Number of Fabric Boards Number of 24- Port 4X interconnect Cards Maximum Number of 4X Link Cables 9024 Leaf Chasses (24*4X)
1 - 3 0-24 1 3 0 1 24 0
4 - 6 0-24 1 3 4 2 48 0
7 - 9 0-24 1 3 4 3 72 0
10 - 12 0-24 1 4 4 4 96 0
Table 1-6: 1-36 Enclosure Configurations Using ISR 2012 Interconnects
Server Blade Enclosures Control and Utility Nodes Number of Managed 9288 Chasses Total Number of Power Supplies Number of Fabric Boards Number of 24-Port 4X Interconnect Cards Maximum Number of 4X Link Cables 9024 Leaf Chasses (24*4X)
1 - 3 0-24 1 3 0 1 24 0
4 - 6 0-24 1 3 4 2 48 0
7 - 9 0-24 1 4 4 3 72 0
10 - 12 0-24 1 4 4 4 96 0
13 - 15 0-24 1 4 4 5 120 0
16 - 18 0-24 1 4 4 6 144 0
19 - 21 0-24 1 4 4 7 168 0
22 - 24 0-24 1 4 4 8 192 0
25 - 27 0-24 1 4 4 9 216 0
28 - 30 0-24 1 5 4 10 240 0
31 - 33 0-24 1 5 4 11 264 0
34 - 36 0-24 1 5 4 12 288 0
Table 1-7: 37-72 Enclosure Configurations Using ISR 2012 Interconnects
Server Blade Enclosures Control  and Utility Nodes Number of Managed 9288 Chasses Total Number of Power Supplies Number of Fabric Boards Number of 24-Port 4X Interconnect Cards Maximum Number of 4x Link Cables 9024 Leaf Chasses (24*4X)
37 - 39 0-24 2 6 8 14 336 2
40 - 42 0-24 2 6 8 14 336 2
43 - 45 0-24 2 8 8 16 384 2
46 - 48 0-24 2 8 8 16 384 2
49 - 51 0-24 2 8 8 18 432 2
52 - 54 0-24 2 8 8 18 432 2
55 - 57 0-24 2 8 8 20 480 2
58 - 60 0-24 2 8 8 20 480 2
61 - 63 0-24 2 8 8 22 528 2
64 - 66 0-24 2 10 8 22 528 2
67 - 69 0-24 2 10 8 24 576 2
70 - 72 0-24 2 10 8 24 576 2