Before beginning the installation, read through the following items to make sure you are prepared to supply the information required by the installation process.

  1. Ensure that you have performed all preinstallation tasks described in “Preparing for a New Installation”, especially the hardware preparation tasks.

  2. Know how to use a text editor (such as vi, emacs, or gedit) because at some points in the system installation and configuration process, you are required to modify text files.

  3. Know the chip architecture for the HP Cluster Platform, which is listed in Table 2-5.

    Table 2-5 Chip Architecture by Cluster Platform

    Cluster Platform ModelChip Architecture
    Cluster Platform 3000 (CP3000) Intel Xeon with EM64T
    Cluster Platform 3000BL (HP server blades)Intel Xeon with EM64T
    Cluster Platform 4000 (CP4000)AMD Opteron
    Cluster Platform 4000BL (HP server blades)AMD Opteron
    Cluster Platform 6000 (CP6000)Intel Itanium 2

     

  4. Ensure that you have in your possession the DVD distribution media that is appropriate for the cluster platform architecture. The XC System Software and the open source software source code DVDs are included in the architecture-specific media kits that were shipped to you.

  5. If the head node is an HP server blade model, you must have the following items available:

    • A PC or laptop with a local DVD drive

    • A recent version of Mozilla Firefox or Internet Explorer running on the PC or laptop

  6. Be prepared to supply the information listed in Table 2-6 during the Kickstart installation session.

    Table 2-6 Information Required for the Kickstart Installation Session

    ItemDescription and User Action

    Software RAID

    If more than two disks are found on the head node, you are prompted to configure software RAID-1 (mirroring), as follows:

    Two or more system disks have been detected.
    Do you want to use software RAID-1 to mirror two disks? (y/n):

    If you answer y (yes), you are prompted to select two disks to mirror.

    Select two disks to mirror with software RAID-1:
    
        Select software RAID-1 disk 1:
        Select software RAID-1 disk 2:

    The following criteria apply to installing and using mirroring on the head node:

    • The head node must have a minimum of two disks.

    • The disks must be the same size.

    The /boot partition on HP Integrity hardware models cannot be configured with software RAID-1.

    HP recommends that you do not configure software RAID on hardware models configured with smart arrays.

    Disk for the installation

    During the installation process, a numbered list of disks discovered on the head node appears, and you are prompted to select a disk on which to install the software:

    Select the disk for the installation:

    The following criteria apply to the disk you select:

    • The disk must be 36 GB or larger.

    • The disk must not be connected to a SAN device.

    Where to create a partition for the /hptc_cluster file system

    The /hptc_cluster file system is the global, or clusterwide, file system on an HP XC system. This file system is shared and mounted by all nodes and contains configuration and log file information that is required for all nodes in the system. This file system is intended for XC management use; do not use it for user accounts or job launching.

    You have the option to create a disk partition for the /hptc_cluster file system somewhere other than the installation disk (also known as the system disk) on the head node. For example, you might want to create a partition for this file system on an HP SFS server for failover capability or on another separate disk on the head node.

    The prompt is similar to the following:

    Do you want to create the XC global file system
    (/hptc_cluster) as a partition on the system disk? (y/n)
    

    If you answer yes , the /hptc_cluster is created on the installation disk. Be aware that placing this file system on the installation disk does not provide any type of failover capability.

    If you answer no to this prompt, you must manually create and mount the /hptc_cluster file system somewhere else. “Create the /hptc_cluster File System ” provides instructions at the appropriate point in the process.

    Reuse existing disk partitions or use default partition table

    If an existing disk partition table that can be reused is detected on the head node installation disk, you are prompted to reuse the existing partitions or apply the HP XC default disk partition table. Choosing the default disk partition table overwrites any data on the installation disk.

    Software RAID-1 automatically creates disk partitions, so if you elect to configure software RAID-1 on the system disk, you are not prompted to re-use existing partitions.

    The prompt is similar to the following:

    Would you like to reuse the existing partition table
    or do you want to use the XC default partition table?
    Enter "r" to reuse or "d" to use the XC default:

    The default partition table is listed in Table 2-3.

    If the existing disk partition table cannot be reused, you have the option to exit the installation process to repartition the system disk manually. Otherwise, you can continue the installation process and apply the default partition table.

    The following messages are displayed if a calculated disk partition size exceeds the size limit and the maximum partition size is applied:

    Instituting a cap on the boot partition.
    Instituting a cap on the root partition.
    Instituting a cap on the /var partition.
    Instituting a cap on the /hptc_cluster partition.
     
    A portion of the disk is not partitioned.

    For some configurations, the 4 GB limit on the size of the /hptc_cluster partition might be too small. See “4 GB /hptc_cluster Partition Size Limit Might Be Too Small For Some Hardware Configurations” for more information.

    Time zone

    Select the time zone in which the system is located. The default is America/New York (Eastern Standard Time, which is Greenwich Mean Time minus 5 hours).

    Use the Tab key to move through the list of time zones, and use the spacebar to highlight the selection. Then, use the Tab key to move to OK, and press the space bar to select OK.

    Root password

    Define a password for the root user. You are prompted to enter it again for verification purposes.

    Use the Tab key to move the cursor on the screen; then, press the spacebar to select OK.

    See “Password Guidelines” for recommendations on choosing strong root passwords.

     