Perform this task only if the hardware configuration contains
HP server blade enclosures.
If the hardware configuration contains HP server
blades housed in enclosures, HP recommends that you configure the
enclosures to send their SNMP traps to the management server IP alias.
After doing so, all SNMP traps are processed by the snmptrapd service and subsequently logged to syslog by
the snmptt service. The syslog-ng service logs all traps to the /hptc_cluster/adm/log/consolidated.log
file and the /hptc_cluster/adm/logs/snmptraps.log file. This enables Nagios to generate alerts for all enclosure traps
posted with a priority of WARNING or greater.
Configure the enclosures to
send their SNMP traps to the management server IP alias:
# manage_enclosure addtrap
enc2n-enc09USE6281BJX: Added SNMP trap receiver destination IP_address |
Verify that the SNMP trap
destination has been set correctly on the enclosures:
# manage_enclosure listtrap
enc2n-enc09USE6281BJX:
IP_address |
Proceed to “Task 17: Configure SNMP Trap Destination for Modular Cooling
System Devices”.