Verify nagios:
Testing configuration ...
Running basic sanity check on the Nagios configuration file.
Starting the command:
/opt/hptc/bin/nagios -v /opt/hptc/nagios/etc/nagios_local.cfg
Here is the output from the command:
Warnings were reported.
Nagios 2.3.1
Copyright (c) 1999-2006 Ethan Galstad (http://www.nagios.org)
Last Modified: 05-15-2006
License: GPL
Reading configuration data...
Warning: Duplicate definition found for service 'nagiosmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 195)
Warning: Duplicate definition found for service 'hostmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 206)
Warning: Duplicate definition found for service 'syslogalertmonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 217)
Warning: Duplicate definition found for service 'keysync'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 232)
Warning: Duplicate definition found for service 'sensorCollectionMonitor'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 252)
Warning: Duplicate definition found for service 'selmon'
(config file '/opt/hptc/nagios/etc/xc-monitor-n8.cfg', starting on line 274)
Running pre-flight check on configuration data...
Checking services...
Warning: Service 'Syslog Alert Monitor' on host 'nh' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made, so
the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'nh' has a notification interval less
than its check interval! Notifications are only re-sent after checks are made, so the
effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'nh' has a notification
interval less than its check interval! Notifications are only re-sent after checks
are made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alert Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n6' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Warning: Service 'System Event Log Monitor' on host 'n6' has a notification
interval less than its check interval! Notifications are only re-sent after checks are
made, so the effective notification interval will be that of the check interval.
Warning: Service 'Syslog Alerts' on host 'n7' has a notification interval
less than its check interval! Notifications are only re-sent after checks are made,
so the effective notification interval will be that of the check interval.
Checked 49 services.
Checking hosts...
.
.
. |