HP ProLiant DL140 G3 and DL145 G3 Node Imaging Fails When
Graphics Cards Are Present |
 |
As described in “Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails
When Graphics Cards Are Present”, the discovery and imaging processes might fail on HP ProLiant
DL140 G3 or DL145 G3 servers containing graphics cards.
The work around for the discovery failure is described
in “Discovery of HP ProLiant DL140 G3 and DL145 G3 Nodes Fails
When Graphics Cards Are Present”, and the work around for the imaging
process described in this section assumes that all nodes were discovered.
Follow this procedure to propagate the golden
image to DL140 G3 and DL145 G3 servers containing a graphics card:
Issue the appropriate startsys command and specify one of the DL140 G3 or DL145
G3 nodes with a graphics card in the [nodelist] option of the startsyscommand.
When power to the node is
turned on, use the cluster console to connect to the node and force
it to PXE boot by pressing the F12 key at the appropriate
time during the BIOS start up.
When the node is successfully
imaged, repeat this process for the remaining nodes containing graphics
cards.
When all nodes containing
graphics cards are imaged, issue the startsys command
without the [nodelist] option to image all remaining nodes of the cluster in parallel.