On hp servers rp7410, rp8400, and superdome only, you might see the following
message after
you have installed the A6829A adapter (it would be displayed at
the BCH “Main Menu”): ERROR: PDH NVRAM and I/O card NVRAM SCSI parameters do not match for path hw_path Search aborted. The SCSI parameters for this card must be corrected from the BCH Service menu. |
To correct this problem, follow these steps: If already at the “Main
Menu,” type ser (for “Service Menu”); go to step 2. If not already at the “Main Menu,” type main (to return to the “Main Menu”), type ser (for “Service Menu”), then go to
step 2. In the “Service Menu,” type
the following command: scsi path default where path is the HBA’s path (the hw_path in the error message). This sets all of the SCSI parameters for the path to their default values, which will correct the unmatching
SCSI parameters. Type main to get back to the “Main Menu.”
|