The supported configuration of an hp Integrity cx2600 Server
includes 1, 2 or 3 Low-Voltage-Differential (LVD), hot-plug disk
drives. If any of the three disk drives are not installed a disk
filler must be installed in the disk location.
Hot-plug disk drives
are located at the front of the server. The following sections describe
removing and reinstalling a disk drive.
 |
 |  |
 |
 | CAUTION: A hot-plug
device may require interaction with the operating system before
the device can be safely removed from or installed into the server.
Determine if the operating system supports replacement of disk drives
while the operating system is running. If the operating system does not
support this feature, shut down the operating system before performing
these procedures. Failure to observe this caution could result in
system failure. |
 |
 |  |
 |
Removing
Hot-Plug Disk Drives |
 |
Slots are provided
for up to three hot-plug disk drives in your hp Integrity cx2600
Server. When disk drives are not installed, filler assemblies are
installed to prevent air leakage and ensure adequate cooling.
To remove a hot-plug disk drive, perform the following steps:
If required (OS does not support hot-plugging
devices), stop the operating system.
Squeeze inward on the colored release clip and pull
the release lever to pull the drive from the server chassis.
Installing
Hot-Plug Disk Drives |
 |
Up to three hot-plug
disk drives may be installed in your hp Integrity cx2600 Server.
Always use low profile disk drives (1.0" height) in your server.
To install a hot-plug disk drive, perform the following steps:
If required (OS does not
support hot-plugging devices), stop the operating system.
If a disk filler is installed, remove it by pulling
the release lever.
With the release lever pulled out, slide a hot-plug
hard disk into the disk slot until it is seated.
Press the release lever until it is flush with the front
of the server. You will hear it click as it locks into position.
If the operating system was stopped in step Step 1, reset the system to the EFI Boot
Maintenance Menu, to rescan the hard drives.
If the operating system was stopped in step Step 1, use the EFI shell map command to
verify that the newly inserted drive has been correctly installed.
Refer to Chapter 5 of this guide (Cable Connections) and to the
hp Integrity cx2600 Operation and Maintenance
Guide for information about connecting a console and
using the EFI shell. (The hp Integrity
cx2600 Operation and Maintenance Guide is included on
the CD provided with your system).