Once your HP Fibre Channel Mass
Storage software and hardware are installed and running, follow these
steps to verify connectivity:
Check
the state of all Fibre Channel hardware and interfaces. Enter the ioscan command and verify that the Hardware State and the
HW-Interface State are CLAIMED.
If the Fibre
Channel device file has not been created, enter the following commands:
# insf -e
# ioscan -f
Verify
that all devices you attached to the Fibre Channel adapter are listed
in the ioscan output. For example, if you have
a direct attach Fibre Channel device attached to the system, the ioscan output may look like the following:
8/12.8.0.255.0.1.0 sdisk CLAIMED DEVICE DGC C3400WDR5 |
The example above is the hardware path of LUN0
of a directly attached Fibre Channel Mass Storage device with Loop
ID of 1. For details on interpreting hardware paths for Fibre Channel
devices, see “Interpreting Hardware Paths”.
If all attached devices are not listed or appear
as UNCLAIMED, see the Troubleshooting and Maintenance chapter of this guide.