HP Instant Capacity User's Guide for versions B.07.x > Chapter 6 Cell Board Instant Capacity

Activation of an Instant Capacity Cell Board

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

 » Index

An Instant Capacity cell board is usually assigned to an nPartition; however, it does not participate in the boot of the nPartition. Activating an Instant Capacity cell board that is licensed is a two step process:

  1. Set the cell board’s use-on-next-boot flag to “y” (yes) using the parmodify command

  2. Perform a reboot of the nPartition (using the shutdown -r command)

Example 6-3 Activating a cell board in cabinet 0, slot 5, nPartition 3

For example, changing the use-on-next-boot flag to “y” on the Instant Capacity cell board in cabinet 0, slot 5, in nPartition 3 can be accomplished via the following command:

/usr/sbin/parmodify -p 3 -m 0/5::y:

If there are available licensed processors in the complex, the number of intended active processors is increased as high as possible, limited by the number of processors in the newly activated cell board. The available processor licenses are automatically used in the cell activation.

After you have set the cell board’s use-on-next-boot flag to “y”, and performed the reboot, you can use the icod_modify command to activate processors that are listed as inactive processors that can be activated (as reported by the icod_stat command).

The number of active processors in the nPartition remains the same after the cell board is made active — unless prior to the cell board’s activation the number of intended active processors is greater than the number of active processors (as reported by the icod_stat command).

Activating an Instant Capacity cell board causes at least one processor to become active on that cell board.

IMPORTANT: The above parmodify command fails if a licensed processor is not available for activation on the newly activated cell board.

See the HP System Partitions Guide for details about adding and configuring cells in nPartitions.