This verb specifies whether SNAplus2 log messages are sent
to a central file from all servers, or to a separate file on each
server. For more information, see “SET_LOG_FILE”.
This verb must be issued to the node that is currently acting
as the central logger; for information about accessing this node,
see “CONNECT_NODE”.
VCB
Structure |
 |
typedef struct set_central_logging { AP_UINT16 opcode; /* verb operation code */ unsigned char reserv2; /* reserved */ unsigned char format; /* reserved */ AP_UINT16 primary_rc; /* primary return code */ AP_UINT32 secondary_rc; /* secondary return code */ unsigned char enabled; /* is central logging enabled? */ } SET_CENTRAL_LOGGING;
|
Supplied
Parameters |
 |
The application supplies the following parameters:
- opcode
AP_SET_CENTRAL_LOGGING
- enabled
Specify whether central logging is enabled or disabled. Possible
values are:
- AP_YES
Central logging is enabled. All log messages are
sent to a single file on the node currently acting as the central
logger.
- AP_NO
Central logging is disabled. Log messages from each
server are sent to a file on that server (specified using the SET_LOG_FILE
verb).
Returned
Parameters: Successful Execution |
 |
If the verb executes successfully, SNAplus2 returns the following parameters:
- primary_rc
AP_OK
- secondary_rc
Not used.
Returned
Parameters: Parameter Check |
 |
If the verb does not execute because of a parameter error,
SNAplus2 returns the following parameters:
- primary_rc
AP_PARAMETER_CHECK
- secondary_rc
- AP_NOT_CENTRAL_LOGGER
The verb was issued to a node that is not the central
logger.
Returned
Parameters: Other Conditions |
 |
Appendix A “Common
Return Codes” lists further
combinations of primary and secondary return codes that are common
to all NOF verbs.