This section describes information about installing the HP Integrity Virtual Machines product and associated software on the VM Host system.
HP Integrity Virtual Machines A.03.00 is installed on HP Integrity servers or nPartitions running HP-UX 11i V2 (September 2006 [0609] or later). For complete information about the requirements for installing Integrity VM, see the HP Integrity Virtual Machines Installation, Configuration, and Administration manual.
When you upgrade or reinstall Integrity VM, guests are stopped, but they are not removed. When the new version of Integrity VM starts, the virtual machines may also start, depending on the setting of the guest boot attribute.
Integrity VM Includes the Foundation Operating Environment |
 |
The HP-UX Foundation Operating Environment (FOE) is included with Integrity VM. Install the FOE on the VM Host on which you install Integrity VM. The license for the FOE (used in the VM Host only) is included with the purchase of Integrity VM. (Licenses for OEs that run inside the individual virtual machines must be purchased separately.)
For VM Hosts that will support guests as Serviceguard packages, the Mission Critical Operating Environment (MCOE) can also be used.
Upgrade HP WBEM Services |
 |
Integrity VM fails to install if the version of WBEM Services on your VM Host is old. The VM Host system must be running HP WBEM Services A.02.00.10 or later. The HP WBEM Services for HP-UX software bundle (B8465BA) is available as part of the HP-UX operating system, or download the software from www.hp.com. This version of HP WBEM Services is also required in order to install VM Provider and VM Manager.
Installing the hpvmmigrate Command |
 |
The hpvmmigrate command is included in the HP Integrity Virtual Machines product, but it is packaged in the separate VMMigrate bundle and must be explicitly specified. You must install the T2767AC bundle before or with the VMMigrate bundle, to make sure the versions of the bundles are compatible.
To install the VM Migrate bundle with the Integrity VM software, enter the following command:
# swinstall -x autoreboot=true -s my.server.foo.com:/depot/path T2767AC VMMigrate |
Installing VM Provider |
 |
To install the VM Provider bundle with the Integrity VM software on the VM Host, enter the following command:
# swinstall -x autoreboot=true -s my.server.foo.com:/depot/path T2767AC VMProvider |
To install the VM Provider bundle with the Integrity VM software on the HP-UX guest, enter the following command:
# swinstall -x autoreboot=true -s my.server.foo.com:/depot/path VMProvider |
If you install the VM Provider on either the VM Host or a guest, make sure that the system is using HP WBEM Services A.02.00.10 or higher. For example:
# swlist WBEMServices
# Initializing...
# Contacting target "alien2"...
#
# Target: alien2:/
#
# WBEMServices A.02.00.11 WBEM Services CORE
Product
WBEMServices.WBEM-CORE A.02.00.11 WBEM Services CORE
Fileset for hp Integrity servers
WBEMServices.WBEM-CORE-COM A.02.00.11 WBEM Services COM
Fileset for hp Integrity servers and hp 9000 servers
WBEMServices.WBEM-MAN A.02.00.11 WBEM Services MAN
Fileset
WBEMServices.WBEM-MX A.02.00.11 WBEM Services MX
fileset |
Ugrade the VM Host to 0609 or Later |
 |
This version of Integrity VM does not run on HP-UX 11.23 versions released before September 2006 (0609). If the VM Host system is running an older versions of HP-UX 11.23, you must upgrade to 0609 or later before you upgrade to the current version of Integrity VM.
HP-UX Patches Required in the VM Host |
 |
Table 2-1 lists the patches that are required in the VM Host system running Integrity VM A.03.00 and later. For patches required for earlier versions of Integrity VM, consult the Release Notes document for that version.
Table 2-1 VM Host Patches
| Affected HP-UX (VM Host) Version | Affected Integrity VM Version | Fix | Description/Impact | Comment |
|---|
| 11.23 0512 or later | A.02.00 or later | PHNE_33724 | Bug Fix | Fixes a problem of a panic on the VM Host. |
| 11.23 0505 or later | A.02.00 or later | PHNE_34474 | Bug Fix | Required when using linkloop over VLANs between guest and VM Host VLAN. |
| 11.23 0505 | A.01.00 or later | Cimserver 02.00.011 PHSS_34429 | Bug Fix | Resolves potential corruption of guest configuration, cimserver, or other WBEM files when under extreme load. Download HP WBEM Services for HP-UX Product Bundle B8465BA from the HP software depot. |
| 11.23 0505 or later | A.01.00 or later | PHNE_34278 | Bug Fix | Resolves panic and system hang symptoms |
| 11.23 0505 or later | A.01.00 or later | PHNE_35182 | Bug Fix | Cumulative ARPA transport patch, resolves panic. Requires prerequisite PHNE_33732 |
| 11.23 Montecito | A.01.20 | HPVM A.02.00 11.23.0609 HWE | Montecito HW support | HPVM V2.0 is strongly recommended for use with Montecito-based systems. |
Patches Required in the HP-UX Guest |
 |
Table 2-2 lists the patches that are required in HP-UX guests:
Table 2-2 HP-UX Guest Patches
| Affected Guest OS and Version | Affected Integrity VM Version | Fix | Description/Impact | Comment |
|---|
| HP–UX 11.23 0505 | A.01.00 or later | U320 SCSI MPT driver version B.11.23.03, bundle A7173A | Includes fixes for performance and stability. | MPT driver update. This patch is included in the 0512 update. |
| HP–UX 11.23 0505 or later | A.01.00 or later | PHKL_34278 | Bug fix | Resolves panic and system hang symptoms. |
| HP–UX 11.23 0505 or later | A.01.00 or later | PHKL_34589 | Bug fix | Resolves panic on guest. |
| 11.23 0606 or later | A.01.20 or later | PHKL_34540 PHKL_34336 PHKL_34928 | Fix to allow sharing of idle CPU cycles between guests. | Ensure loaded when using 0606 and later. Must be manually installed if feature 11i is not installed. Without this patch, Integrity VM may not detect guest is idle and not share resources, heavily impacting performance. |
| 11.23 0505 or later | A.01.00 or later | PHKL_33823 | Bug Fix | Resolves panic on guest. |
| 11.23 0505 or later | A.02.00 or later | PHSS_34760 | Serviceguard Monitor fix | Required for running in Serviceguard 11.16 environment. |
| 11.23 0505 or later | A.02.00 or later | PHSS_34337 | Serviceguard Monitor fix | Required for running in Serviceguard 11.17 environment. |
| 11.23 0505 or later | A.01.00 or later | Cimserver 02.00.09 (PHSS_34429) | Bug fix | Resolves potential corruption of guest configuration, cimserver, or other WBEM Services files when under extreme load. |
| 11.23 0505 or later | A.01.00 or later | PHNE_35182 | Bug fix | Cumulative ARPA transport patch, resolves panic. Requires prerequisite PHNE_33732 |
| 11.23 Montecito | A.01.20 or later | HPVM A.02.00 11.23.0609 HWE | Montecito hardware support | Integrity VM V2.0 or later is strongly recommended for use with Montecito-based systems. |
For more information about updates to HP-UX software, contact your HP representative or support specialist.
Table 2-3 lists patches and products that you should not install on HP-UX guests. In guests where these patches are installed, degradations and regressions have been observed.
Table 2-3 Do Not Install Products or Patches on HP-UX Guests
| Affected Guest OS and Version | Affected Integrity VM Version | Fix | Description/Impact | Comment |
|---|
| HP–UX 11.23 0505 or later | A.01.00A.01.20 | PHKL_33361 | Cumulative kernel SCSI patch | Resolved in Integrity VM A.02.00 and later. |
| HP–UX 11.23 0505 or later | A.01.00A.01.20A.02.00 | PHKL_35739 | VxVM 4.1 Kernel Patch 04 | Resolved in Integrity VM A.03.00 and later. |
Patches Required for Ignite/UX Servers |
 |
Table 2-4 lists the patches that are required in the guests:
Table 2-4 Ignite/UX Patches
| Affected OS and Version | Affected Integrity VM Version | Fix | Description/Impact | Comment |
|---|
| HP–UX 11.00 | A.01.00 or later | PHKL_25355 | tftpd | |
| HP–UX 11.11 | A.01.00 or later | PHKL_32825 | tftpd | |
Patches Required for Windows Guests |
 |
Table 2-5 lists the patches that are required in the guests.
Table 2-5 Windows Patches
| Affected Guest OS and Version | Affected Integrity VM Version | Fix | Description/Impact | Comment |
|---|
| Windows Server 2003 | A.02.00 or later | SSM 4.6 | Bug Fix` | Microsoft patches correct a compiler issue that can affect Windows guests in various ways. |
Table 2-6 lists patches and products that you should not install on Windows guests.
Table 2-6 Do Not Install Products or Patches on Windows Guests