Use the mx command of the zmntr utility to view the current mode of the ports on a given MUX. For example, to view the ports on MUX 1 of an 8 channel HP-PB (NIO) ACC card:

HPAMS1R> zmntr
ZMNTR: ZCOM 6.2.0.0 Runtime Monitor, Rev 1.0
ZMNTR> mx,1
Interface card information for ACC X.25 ttgen input file

TTGEN source /usr/zcom/opt/acc/cfg/duplex.answ
object /usr/zcom/opt/acc/cfg/duplex.tmem

Mux:01 Bus:00/01 Slot:03 Trms:0004 Card Stat:Up and active
Firmware download file: /usr/zcom/opt/acc/z7200a/x25.zabs
Module: X25 Linktime: Mon Aug 18 15:55:37 1997
ROM-ID: UMUX302A [04.X] Updated: Tue Aug 04 08:50:00 1992
Connection: Dual system RS232 panel Mux MPU utiliz: 1%

Pt# Status TXlim TXusd PMode Cmode Ecde Clk Baudrate Mult Parity Stbits
0 Up 20000 0 TriSt SDLC NRZ Int 9,600 X.1 None
1 Up 20000 0 TriSt SDLC NRZ Ext 9,600 X.1 None
2 Up 20000 0 TriSt SDLC NRZ Int 9,600 X.1 None
3 Up 20000 0 TriSt SDLC NRZ Ext 9,600 X.1 None
4 Up 20000 0 TriSt SDLC NRZ Int 9,600 X.1 None
5 Up 20000 0 TriSt SDLC NRZ Ext 9,600 X.1 None
6 Up 20000 0 TriSt SDLC NRZ Int 9,600 X.1 None
7 Up 20000 0 TriSt SDLC NRZ Ext 9,600 X.1 None
ZMNTR>

This example shows that the mode of all ports on this ACC card is “Tri-state” which is the same as Loopback. The following example shows ACC card 0 having all ports in RS-232 mode:

ZMNTR> mx,0
Interface card information for ACC X.25 ttgen input file

TTGEN source /usr/zcom/opt/acc/cfg/duplex.answ
object /usr/zcom/opt/acc/cfg/duplex.tmem

Mux:00 Bus:00/01 Slot:02 Trms:0004 Card Stat:Up and active
Hardware Revison: Rev.A
Firmware download file: /usr/zcom/opt/acc/z7200a/x25.zabs
Module: X25 Linktime: Mon Mar 24 15:55:37 1997
ROM-ID: UMUX302A [04.X] Updated: Tue Aug 04 08:50:00 1992
Connection: Dual system RS232 panel Mux MPU utiliz: 1%

Pt# Status TXlim TXusd PMode Cmode Ecde Clk Baudrate Mult Parity Stbits
0 Up 20000 0 RS232 SDLC NRZ Int 9,600 X.1 None
1 Up 20000 0 RS232 SDLC NRZ Ext 9,600 X.1 None
2 Up 20000 0 RS232 SDLC NRZ Int 9,600 X.1 None
3 Up 20000 0 RS232 SDLC NRZ Ext 9,600 X.1 None
4 Up 20000 0 RS232 SDLC NRZ Int 9,600 X.1 None
5 Up 20000 0 RS232 SDLC NRZ Ext 9,600 X.1 None
6 Up 20000 0 RS232 SDLC NRZ Int 9,600 X.1 None
7 Up 20000 0 RS232 SDLC NRZ Ext 9,600 X.1 None
ZMNTR>