ACC Error Guide > Chapter 13 ZX25D System Messages

CLASS: Serious 300-399

» 

Technical documentation

Complete book in PDF
» Feedback
Content starts here

 » Table of Contents

zx25d 300 X.25 initialization failure; zinit failed with error <#>!

Explanation:

The ZCOM API routine zinit has unexpectedly failed due to the indicated ZCOM error during the initialization of the ACC X.25 subsystem. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for the failure and take corrective action as necessary. If the problem persists and you are unable to correct the problem or the error indicates an internal failure, contact your HP support representative.

zx25d 301 X.25 initialization failure; zopen failed with error <#>!

Explanation:

The ZCOM API routine zopen has unexpectedly failed due to the indicated ZCOM error during the initialization of the ACC X.25 subsystem. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for the failure and take corrective action as necessary. If the problem persists and you are unable to correct the problem or the error indicates an internal failure, contact your HP support representative.

zx25d 302 X.25 initialization failure; zsetkfunc failed with error <#>!

Explanation:

The ZCOM API routine zsetkfunc has unexpectedly failed due to the indicated ZCOM error during the initialization of the ACC X.25 subsystem. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for the failure and take corrective action as necessary. If the problem persists and you are unable to correct the problem or the error indicates an internal failure, contact your HP support representative.

zx25d 303 X.25 initialization failure; zevent_rcvr failed with error <#>!

Explanation:

The ZCOM API routine zevent_rcvr has unexpectedly failed due to the indicated ZCOM error during the initialization of the ACC X.25 subsystem. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for failure and take corrective action as necessary. If the problem persists and you are unable to correct the problem or the error indicates an internal failure, contact your HP support representative.

zx25d 304 Too many errors; ACC X.25 subsystem is unusable!

Explanation:

The ZCOM API routine zread has unexpectedly failed three consecutive times in a row. Each failure will have logged a separate error message indicating the specific reason for the failure. These messages should appear immediately prior to this message in the ZCOM log file. The zread routine is used to retrieve all user application requests and X.25 protocol events. Since the X.25 protocol driver is unable to retrieve critical data and status messages, the X.25 subsystem has been shutdown. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for failure and take corrective action as necessary. If the problem persists and you are unable to correct the problem or the error indicates an internal failure, contact your HP support representative.

zx25d 305 Infinite loop detected in the PTT group linkage! The X.25 link ZLU <#> will not be usable.

Explanation:

While scanning the Physical Terminal Table for all Virtual Circuit ZLUs associated with the indicated X.25 link ZLU, the X.25 Protocol driver detected that it had gone into an infinite loop due to a corrupt PTT group linkage word. This could only occur as a result of an internal defect. Since the X.25 protocol driver was unable to find all of the ZLUs associated with the X.25 link, the link has been marked as unusable.

Action:

This is an internal defect in the ZCOM product. Contact your HP support representative.

zx25d 306 ACC X.25 subsystem initialization failure; zsetql() on ZLU <#> failed with error <#>!

Explanation:

The ZCOM API routine zsetql has unexpectedly failed due to the indicated ZCOM error during the initialization of the ACC X.25 subsystem. The X.25 subsystem will not be usable until this error is corrected.

Action:

Examine the specific reason for the failure and take corrective action as necessary. If you are unable to correct the problem and the error indicates an internal failure, contact your HP support representative.