CPE Monitor (Events)
Event
100101
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by PCI bus.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred on the Host Bridge Adapter (Elroy). The
PCI card connected to this adapter is at slot (n). More Information is
available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100102
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by PCI bus.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred on the Host Bridge Adapter (Mercury).
The PCI card connected to this adapter is at slot (n). More Information
is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100103
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by PCI bus.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred on the Host Bridge Adapter.
More Information is available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Lower Bridge Adapter Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100104
- Severity: MAJORWARNING
- Event Summary: A Corrected Platform Error was reported by PCI bus.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error was logged by the Host Bridge Adapter. More information is available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have the Host Bridge Adapter Interfaces checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100105
- Severity: Major Warning
- Event Summary: PCI Error Recovery was attempted and was successful.
- Event Class: CPE
- Problem Description: A platform error was corrected by the firmware/hardware.The error was logged by the Host Bridge Adapter. Auto recovery was attempted and it succeeded.
- Recommended Action: Contact your HP Support Representative to have the Host Bridge Adapter Interfaces checked.
- Automated Recovery: Successful
- Event Generation Threshold: Not used.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause of the CPE.
Event 100106
- Severity: Major Warning
- Event Summary: PCI Error Recovery was attempted but failed.
- Event Class: CPE
- Problem Description: A platform error was reported by the firmware/hardware. The error was logged by the Host Bridge Adapter. Auto recovery was being attempted and it failed. More information is available in the Event Details section of this event.
- Recommended Action: Try manual PCI error recovery procedure. Contact your HP Support Representative to have the Host Bridge
Adapter Interfaces checked.
- Automated Recovery: Failed
- Event Generation Threshold: Not used.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause of the CPE.
Event 100199
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by PCI bus.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred on the Host Bridge Adapter. The data is
insufficient to indicate where the error occurred. More Information may be
available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of the CPE with unknown source. Default threshold is 3 events in
24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100201
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by Rope/IOC
controller.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the Rope I/O Controller (Pluto). The
PCI card connected to this controller is at slot (n). More Information
is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used
- Event Details: The event details will different for each cause of
the CPE.
Event 100202
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by Rope/IOC
controller.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the Rope I/O Controller (Elroy). The
PCI card connected to this controller is at slot (n). More Information
is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100203
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported by Rope/IOC
controller.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the Rope I/O Controller (Mercury).
The PCI card connected to this controller is at slot (n). More
Information is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100204
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the Rope I/O Controller (HP
Platform). More Information is available in the Event Details section of this
event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell, sba and rope. Default threshold is
3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used
- Event Details: The event details will different for each cause of
the CPE.
Event 100211
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the System Bus Adapter of cell
(n). More Information is available in the Event Details section of this
event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100212
- Severity: Major Warning
- Event Summary: A Corrected OEM Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the System Bus Adapter Link Interface
of cell (n). More Information is available in the Event Details section
of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100213
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PCI card in slot (n) of
cell (n). More Information is available in the Event Details section of
this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell and rope. By default, 3 events in
24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100214
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the System Bus Adapter Interface. The
PCI card connected to this adapter is at slot (n) in cell (1). More
Information is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell and rope. By default, 3 events in
24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100215
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the crossbar controller of cell
(n). More Information is available in the Event Details section of this
event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100216
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the POUT0 interface between the cell
controller and the processor of cell (n). More Information is available
in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100217
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PIN0 interface between the cell
controller and the processor of cell (n). More Information is available
in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100218
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the POUT1 interface between the cell
controller and the processor of cell (n). More Information is available
in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100219
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PIN1 interface between the cell
controller and the processor of cell (n). More Information is available
in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100220
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in control status registers (CSR) of
port (n) of crossbar controller (4) of cell (n). More
Information is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100221
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in port (4) of crossbar controller
(n) of cell (n). More Information is available in the Event
Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE on the same cell. By default, 3 events in 24-hour
period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100222
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the ROUT interface between the cell
controller and the processor. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100223
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PIN0 interface between the cell
controller and the processor. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100224
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PIN0 interface between the cell
controller and the processor. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100225
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the POUT1 interface between the cell
controller and the processor. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100226
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PIN1 interface between the cell
controller and the processor. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100227
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the firmware/hardware. The error
occurred in the receiving block. More information is available in the
Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100228
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the firmware/hardware. The error occurred in the transmission block. More information is available
in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller Interfaces checked if these errors persist.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100229
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the System Bus Adapter Link
interface. More Information is available in the Event Details section of this
event.
- Recommended Action : Contact your HP Support Representative to have
the System Bus Adapter Interface to I/O Controller checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100230
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the crossbar controller. More
Information is available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Crossbar Controller checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100236
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the firmware/hardware. The error occurred in the input Link Interface of the Cell Controller. More information is available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have the Cell Controller Interfaces checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period. By default, event is DISABLED.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100237
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the cell controller and the IO controller. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to IO Interface checked. Check the FRUs: Cell-IO cable, IO
chassis, IO backplane, cell, or system backplane.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100238
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: Multiple platforms errors were detected and
corrected by the firmware/hardware. The errors occurred between the cell
controller and the IO controller. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable,
IO chassis, IO backplane, cell, or system backplane.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100239
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar controller and the backplane. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane Interface checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100240
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: Multiple platform errors were detected by the
firmware/hardware. The errors occurred between the crossbar controller and the
backplane. More Information is available in the Event Details section of this
event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane Interface checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100241
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar controller and the backplane. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100242
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: Multiple platform errors were detected and
corrected by the firmware/hardware. The errors occurred between the crossbar
controller and the backplane. More Information is available in the Event
Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane Interface checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100243
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar chips on the backplane(s). More Information is available
in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the backplane and/or connections between backplanes checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100244
- Severity: Major Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: Multiple platform errors were detected and
corrected by the firmware/hardware. The errors occurred between the crossbar
chips on the backplane(s). More Information is available in the Event Details
section of this event.
- Recommended Action : Contact your HP Support Representative to have
the backplane and/or connections between backplanes checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3 events
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100245
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the cell controller and the IO controller. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to IO Interface checked. Check these FRUs: Cell-IO cable,
IO chassis, IO backplane, cell, or system backplane.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100246
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar controller and the backplane. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane Interface checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100247
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar controller and the backplane. More Information is
available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the Cell Controller to backplane Interface checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100248
- Severity: Minor Warning
- Event Summary: A Corrected Platform Error was reported.
- Event Class: CPE
- Problem Description: A platform error was detected by the
firmware/hardware, and corrected by using a spare channel. The error occurred
between the crossbar chips on the backplane(s). More Information is available
in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have
the backplane and/or connections between backplanes checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 1 event
in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100249
- Severity: MINORWARNING
- Event Summary: A Corrected Platform Error was reported by Rope/IOC controller.
- Event Class: CPE
- Problem Description: A platform error was corrected by the firmware/hardware. The error occurred in the Rope I/O Controller. More information is available in the Event Details section of this event.
- Recommended Action : Contact your HP Support Representative to have the System Bus Adapter
Interface to I/O Controller checked.
- Automated Recovery: None
- Event Generation Threshold: Every threshold occurrence of CPE at the same Physical Location. Default threshold is 3 events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will be different for each cause
of the CPE.
Event 100299
- Severity: Major Warning
- Event Summary: An unknown type of HP-Platform Corrected Platform
Error was reported.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred on the I/O Controller. The data is
insufficient to indicate where the error occurred. More Information may be
available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE with unknown source. Default threshold is 3 events in
24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100301
- Severity: Major Warning
- Event Summary: A Platform Corrected Platform Error was reported by
a PCI component.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PCI Component (HP Platform). More
Information is available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE at the same Physical Location. Default threshold is 3
events in 24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Event 100399
- Severity: Major Warning
- Event Summary: An unknown type of Corrected Platform Error was
reported by a PCI component.
- Event Class: CPE
- Problem Description: A platform error was corrected by the
firmware/hardware. The error occurred in the PCI Component. The data is
insufficient to indicate where the error occurred. More Information may be
available in the Event Details section of this event.
- Recommended Action : No action is necessary.
- Automated Recovery: None
- Event Generation Threshold: Every threshold
occurrence of CPE with unknown source. Default threshold is 3 events in
24-hour period.
- Fault Notifier Generation Threshold: Not used.
- Event Details: The event details will different for each cause of
the CPE.
Top
of Page
/ Diagnostics
HOME
URL:
http://docs.hp.com/en/diag/ems/cpe_em.htm
Last
updated: Thursday, Feb 28 2008