EMS Hardware Monitors (logo)

Fibre Channel SCSI Multiplexer Monitor (Events)

NOTE: The June 2001 Release replaced event numbers 0-19 with numbers 200-219 respectively. For the new numbers, add 200 to the original number.

Event 0 (Replaced by 200 in June 2001)

Event Details:

>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:05 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:05 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 200                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 0 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1d00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#200

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FF E4   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FE F4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 1 (Replaced by 201 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:05 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 201                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 1 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1d00000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#201

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 20   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 48   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 2 (Replaced by 202 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 202                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 2 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#202

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 C0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 84   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 3 (Replaced by 203 in June 2001)

Event Details:

                     >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 203                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 3 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#203

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 34   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 D4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 4 (Replaced by 204 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 204                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of all SCSI, FC,
     and memory cards. Check all of the SCSI cables for proper connection and
     termination and check the connector screws. If the problem still persists,
     contact HP for replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#204

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FE E0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF 08   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 6 (Replaced by 206 in June 2001)

Event Details:

                   >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:07 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 206                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of all SCSI, FC,
     and memory cards. Check all of the SCSI cables for proper connection and
     termination and check the connector screws. If the problem still persists,
     contact HP for replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000006
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#206

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FE B8   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF A8   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 7 (Replaced by 207 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:07 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:07 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 207                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Memory Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of memory board
     card. If the problem persists, then contact HP for replacement of the
     memory board.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1f00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#207

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FF 94   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF 44   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 8 (Replaced by 208 in June 2001)

Event Details:

                     >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 17:51:48 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MINORWARNING(2).



Event data from monitor:

Event Time..........: Wed Mar 21 17:51:48 2001
Severity............: MINORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 208                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     LCD Failed

Probable Cause / Recommended Action:

     The MUX has entered the offline condition due to commands from the front
     panel or failed hardware or improper installation. Use the front panel
     controls to put the MUX online. Check for improper installation of all
     cards and the front panel assembly. If the problem persists, then contact
     HP for replacement of the front panel assembly.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95ab400000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#208

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 9 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 1

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 5F 73 63   73 69 5F 6D   75 78 00 9D   00 00 00 20
          0x0020: 00 05 00 00   00 00 00 02   00 00 00 0B   00 00 00 00
          0x0030: 00 00 00 0F   00 00 00 09   00 00 00 3C   00 00 00 00
          0x0040: 40 01 4E D4   00 00 01 61   00 00 00 00   2F 76 61 72
          0x0050: 2F 73 74 6D   2F 63 6F 6E   66 69 67 2F   74 6F 6F 6C
          0x0060: 73 2F 6D 6F   6E 69 74 6F   72 2F 64 65   66 61 75 6C
          0x0070: 74 5F 64 6D   5F 66 63 5F   73 63 73 69   5F 6D 75 78
          0x0080: 2E 63 6C 63   66 67 00 00   00 00 00 00   00 00 00 00
          0x0090: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x00A0: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 9 (Replaced by 209 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 12:38:21 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/10_12.8.0.255.0.4.0
 is >= 1.
Its current value is MAJORWARNING(3).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 12:38:20 2001
Severity............: MAJORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 209                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 10/12.8.0.255.0.4.0 : Hardware warning.


Description of Error:

     FC SCSI MUX not responding.

Probable Cause / Recommended Action:

     The MUX has entered the offline condition due to one of many possible
     causes.  Commands from the front panel or failed hardware or improper
     installation may have caused the MUX to go offline.  The MUX may have
     reset itself due to network event.  A problem may exist in the Fibre
     Channel network.  Normally the MUX and I/O operations will recover
     automatically from reset.  Determine if the MUX resumes responding.  No
     action needed if the MUX resumes responding.  Use the front panel controls
     to put the MUX online.  Check for improper installation of all cards.  If
     the FC adapter on the host or a device attached to the MUX also reports
     errors, the fiber cable may be defective or not attached.  Check the fiber
     cabling between the MUX and the host. The MUX front panel or serial port
     user interface may provide additional information.  If the problem
     persists, then check the Fibre Channel network connected to the MUX. 

     The MUX will not respond if it does not have the correct firmware.
     Firmware with date code 3810 or earlier does not support the polling done
     by this monitor. If the MUX has 3810 or earlier firmware, then download
     the latest firmware.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab9113c00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#209

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location:
    Firmware Revision (Not Available):
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 329

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 02
          0x0000: 00 00 00 01  


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 10 (Replaced by 210 in June 2001)

Event Details:

                          >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:50 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:50 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 210                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     FC port A failed.

Probable Cause / Recommended Action:

     The FC port of the MUX failed selftest due to failed hardware or improper
     installation. Check the FC card for proper seating. If the problem
     persists, then contact HP for replacement of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673200000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#210

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 581

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0A 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 07  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 24   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FE 60   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 11 (Replaced by 211 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:52 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:51 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 211                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     FC port B failed.

Probable Cause / Recommended Action:

     The FC port of the MUX failed selftest due to failed hardware or improper
     installation. Check the FC card for proper seating. If the problem
     persists, then contact HP for replacement of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673300000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#211

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 582

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0B 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 08  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 01 00 2C   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 40   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                

Event 12 (Replaced by 212 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:53 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:53 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 212                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother board processor failed.

Probable Cause / Recommended Action:

     The MUX failed selftest. Check seating of all SCSI, FC, and memory cards.
     Check all of the SCSI cables for proper connection and termination and
     check the connector screws. If the problem still persists, contact HP for
     replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673500000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#212

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 583

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0C 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 09  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FF A0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF F0   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 13 (Replaced by 213 in June 2001)

Event Details:

                    >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:54 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MINORWARNING(2).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:54 2001
Severity............: MINORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 213                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Information.


Description of Error:

     Code assertion occurred.

Probable Cause / Recommended Action:

     The firmware or processor on the MUX has detected a firmware or hardware
     failure and was in an inconsistent state. The MUX has reset itself. This
     event does not require a corrective action if it does not reoccur. If this
     event does reoccur, report this event with its associated data to HP.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673600000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#213

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 584

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0D 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 0A  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 01 00 2C   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED B0   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF DC   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 14 (Replaced by 214 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:55 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:55 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 214                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware warning.


Description of Error:

     Unknown hardware failure.

Probable Cause / Recommended Action:

     The MUX failed selftest but could not determine the exact cause. This
     event could occur if a fan failure was previously reported, but the fan
     was not replaced, and another fan failed. Check the fan cables and
     connectors, and check to see that both fans are operational.  Replace the
     fan assembly if it is found to be defective. If the fan is not defective,
     the cause may be another MUX component. Report this event with its
     associated data to HP.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673700000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#214

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 585

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 10  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FF C8   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 40   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 15 (Replaced by 215 in June 2001)

Event Details:

                          >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 01:33:00 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MAJORWARNING(3).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 01:32:59 2001
Severity............: MAJORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 215                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware warning.


Description of Error:

     Fan module failed.

Probable Cause / Recommended Action:

     One of the two MUX cooling fans has failed. The fan may have something
     blocking it such as the fan cable. The fan may have an improperly
     installed or disconnected cable. The MUX will continue to operate as long
     as the remaining fan provides sufficient cooling. Check the fan cables and
     connectors. Check if both fans run and trouble shoot to find the exact
     cause. Replace the fan assembly if it is found to be defective.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8754b00000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#215

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 5 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 658

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0F 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 02  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 74   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF B4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 16 (Replaced by 216 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:49 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Mar 21 00:32:48 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 216                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : FC external
     loopback test did not pass.


Description of Error:

     FC port A external loopback test Failed.

Probable Cause / Recommended Action:

     The FC loopback test has failed. Check for proper installation of the
     loopback cable. Check to make sure that the FC port cover connector was
     not used during the test instead of the loopback cable (the FC port cover
     does not provide loopback capability). Check the FC card for proper
     seating. Disconnect and reconnect the FC cable and perform the external
     loopback test again. If the problem persists, contact HP for replacement
     of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673000000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#216

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 577

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0A 00   00 16 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 03  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 EC 08   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 10   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 EE 00   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 68   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 17 (Replaced by 217 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:49 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:49 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 217                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : FC external
     loopback test did not pass.


Description of Error:

     FC port B external loopback test Failed.

Probable Cause / Recommended Action:

     The FC loopback test has failed. Check for proper installation of the
     loopback cable. Check to make sure that the FC port cover connector was
     not used during the test instead of the loopback cable (the FC port cover
     does not provide loopback capability). Check the FC card for proper
     seating. Disconnect and reconnect the FC cable and perform the external
     loopback test again. If the problem persists, contact HP for replacement
     of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673100000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#217

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 579

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0B 00   00 16 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 05  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 EC 08   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 10   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 EE 00   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FD D4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 19 (Replaced by 219 in June 2001)

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 13:24:52 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/10_12.8.0.255.0.4.0
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Mar 21 13:24:52 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 219                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 10/12.8.0.255.0.4.0 : Hardware warning.


Description of Error:

     FC SCSI MUX has started responding.

Probable Cause / Recommended Action:

     The MUX has entered the online condition due one of many possible causes. 
     The MUX may have powered up.  The MUX may have been connected or
     re-connected to the Fibre Channel network.  The MUX may have reset itself
     due to a network event.  A problem may have existed in the Fibre Channel
     network and now does not exist. The MUX may have had firmware with date
     code 3810 or earlier, replaced by newer firmware. After download with
     newer firmware, the MUX has the capability to handle polling by this
     monitor. 

     Normally the MUX and I/O operations will recover automatically from reset.
     No action is required. 

     This event has the same severity as MUX not responding event so that when
     one event appears, so can the other.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab91c2400000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#219

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location:
    Firmware Revision (Not Available):
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 988

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 02
          0x0000: 00 00 00 02  


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 100

Event 101

Event 103

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Feb 21 10:29:21 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/10_12.8.0.255.0.4.0
 is >= 1.
Its current value is INFORMATION(1).

Event data from monitor:

Event Time..........: Wed Feb 21 10:29:21 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 103                 
System..............: hprdstl6.rose.hp.com

Summary:
     Disk at hardware path 10/12.8.0.255.0.4.0 : Test event


Description of Error:

     This is a test message from the monitor to test the communication path
     from the monitor to the notification mechanism.

Probable Cause / Recommended Action:

     No action required.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3a94090100000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.24.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#103

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
   FC Path 1: 8/12.8.0.255.0.5
   FC Path 2: 10/8.0.255.0.5.0
   World Wide Name: 0x20000060-0xB02AE242
   Product Number..............: HP A3308

>---------- End Event Monitoring Service Event Notification ----------<
                
                

Event 200

Event Details:

>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:05 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:05 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 200                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 0 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1d00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#200

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FF E4   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FE F4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 201

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:05 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 201                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 1 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1d00000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#201

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 20   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 48   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 202

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 202                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 2 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#202

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 C0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 84   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

Event 203

Event Details:

     >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 203                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     SCSI Card 3 failed.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of SCSI Card and
     check SCSI cable for loose connection and termination. If the problem
     persists, replace the SCSI card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#203

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 01 00 34   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 01 00 D4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

Event 204

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:06 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 204                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of all SCSI, FC,
     and memory cards. Check all of the SCSI cables for proper connection and
     termination and check the connector screws. If the problem still persists,
     contact HP for replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#204

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FE E0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF 08   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                

Event 206

Event Details:

   >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:07 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:06 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 206                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of all SCSI, FC,
     and memory cards. Check all of the SCSI cables for proper connection and
     termination and check the connector screws. If the problem still persists,
     contact HP for replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1e00000006
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#206

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FE B8   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF A8   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 207

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 18:02:07 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Mar 21 18:02:07 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 207                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Memory Board Failed Selftest.

Probable Cause / Recommended Action:

     Failed hardware or improper installation. Check seating of memory board
     card. If the problem persists, then contact HP for replacement of the
     memory board.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95d1f00000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#207

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 19 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 165

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 4D   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 D5 4D   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 F1 D8   40 01 D5 B8   76 00 33 61
          0x0060: 40 00 FF 94   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 F6 60   40 01 E9 08   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 D5 D5   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 D6 00
          0x00A0: 40 01 D6 48   73 69 5F 6D   40 00 FF 44   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                

Event 208

Event Details:

     >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 17:51:48 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MINORWARNING(2).



Event data from monitor:

Event Time..........: Wed Mar 21 17:51:48 2001
Severity............: MINORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 208                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     LCD Failed

Probable Cause / Recommended Action:

     The MUX has entered the offline condition due to commands from the front
     panel or failed hardware or improper installation. Use the front panel
     controls to put the MUX online. Check for improper installation of all
     cards and the front panel assembly. If the problem persists, then contact
     HP for replacement of the front panel assembly.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab95ab400000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#208

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 13 day; 9 hour; 9 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 1

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 01  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 5F 73 63   73 69 5F 6D   75 78 00 9D   00 00 00 20
          0x0020: 00 05 00 00   00 00 00 02   00 00 00 0B   00 00 00 00
          0x0030: 00 00 00 0F   00 00 00 09   00 00 00 3C   00 00 00 00
          0x0040: 40 01 4E D4   00 00 01 61   00 00 00 00   2F 76 61 72
          0x0050: 2F 73 74 6D   2F 63 6F 6E   66 69 67 2F   74 6F 6F 6C
          0x0060: 73 2F 6D 6F   6E 69 74 6F   72 2F 64 65   66 61 75 6C
          0x0070: 74 5F 64 6D   5F 66 63 5F   73 63 73 69   5F 6D 75 78
          0x0080: 2E 63 6C 63   66 67 00 00   00 00 00 00   00 00 00 00
          0x0090: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x00A0: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00


>---------- End Event Monitoring Service Event Notification ----------<
                
                

Event 209

Event Details:

                
                 >------------ Event Monitoring Service Event Notification ------------<

otification Time: Wed Mar 21 12:38:21 2001
hprdstl6 sent Event Monitor notification information:
/connectivity/events/multiplexors/FC_SCSI_mux/10_12.8.0.255.0.4.0
is >= 1.
ts current value is MAJORWARNING(3).
User Comments:
Test 1/23/01
Event data from monitor:
Event Time..........: Wed Mar 21 12:38:20 2001
everity............: MAJORWARNING
onitor.............: dm_fc_scsi_mux
vent #.............: 209                 
ystem..............: hprdstl6.rose.hp.com
Summary:
    Multiplexor (MUX) at hardware path 10/12.8.0.255.0.4.0 : Hardware warning.

escription of Error:
     FC SCSI MUX not responding.
Probable Cause / Recommended Action:
     The MUX has entered the offline condition due to one of many possible
    causes.  Commands from the front panel or failed hardware or improper
    installation may have caused the MUX to go offline.  The MUX may have
    reset itself due to network event.  A problem may exist in the Fibre
    Channel network.  Normally the MUX and I/O operations will recover
    automatically from reset.  Determine if the MUX resumes responding.  No
    action needed if the MUX resumes responding.  Use the front panel controls
    to put the MUX online.  Check for improper installation of all cards.  If
    the FC adapter on the host or a device attached to the MUX also reports
    errors, the fiber cable may be defective or not attached.  Check the fiber
    cabling between the MUX and the host. The MUX front panel or serial port
    user interface may provide additional information.  If the problem
    persists, then check the Fibre Channel network connected to the MUX. 
     The MUX will not respond if it does not have the correct firmware.
    Firmware with date code 3810 or earlier does not support the polling done
    by this monitor. If the MUX has 3810 or earlier firmware, then download
    the latest firmware.
Additional Event Data: 
    System IP Address...: 15.8.135.196
    Event Id............: 0x3ab9113c00000000
    Monitor Version.....: B.01.01
    Event Class.........: I/O
    Client Configuration File...........:
    /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
    Client Configuration File Version...: A.01.00 
         Qualification criteria met.
              Number of events..: 1 
    Associated OS error log entry id(s): 
         None
    Additional System Data:
         System Model Number.............: 9000/831 
         EMS Version.....................: A.03.20 
         STM Version.....................: A.26.00 
    Latest information on this event:
         http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#209
v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v

Component Data: 
    FC Path 1...................: 8/12.8.0.255.0.5.0
    FC Path 2...................: 10/12.8.0.255.0.4.0
    World Wide Name.............: 0x20000060b02ae242
    Product Number..............: HP A3308
Product/Device Information:
    World Wide Name: 0x20000060-0xB02AE242
   MUX Location:
   Firmware Revision (Not Available):

   Each path, for which this event gets generated, will have this same
   duplicate event number : 329
Manager-Specific Information: 
     Raw Manager Data:
         0x0000: 00 02
         0x0000: 00 00 00 01  

---------- End Event Monitoring Service Event Notification ----------<
 

Event 210

Event Details:

          >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:50 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:50 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 210                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     FC port A failed.

Probable Cause / Recommended Action:

     The FC port of the MUX failed selftest due to failed hardware or improper
     installation. Check the FC card for proper seating. If the problem
     persists, then contact HP for replacement of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673200000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#210

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 581

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0A 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 07  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 24   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FE 60   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<
                
                

Event 211

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:52 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:51 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 211                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     FC port B failed.

Probable Cause / Recommended Action:

     The FC port of the MUX failed selftest due to failed hardware or improper
     installation. Check the FC card for proper seating. If the problem
     persists, then contact HP for replacement of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673300000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#211

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 582

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0B 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 08  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 01 00 2C   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 40   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                

Event 212

Event Details:

                
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:53 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is CRITICAL(5).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:53 2001
Severity............: CRITICAL
Monitor.............: dm_fc_scsi_mux
Event #.............: 212                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware problem.


Description of Error:

     Mother board processor failed.

Probable Cause / Recommended Action:

     The MUX failed selftest. Check seating of all SCSI, FC, and memory cards.
     Check all of the SCSI cables for proper connection and termination and
     check the connector screws. If the problem still persists, contact HP for
     replacement of the motherboard.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673500000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#212

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 583

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0C 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 09  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FF A0   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF F0   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<
                
                

Event 213

Event Details:

                    >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:54 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MINORWARNING(2).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:54 2001
Severity............: MINORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 213                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Information


Description of Error:

     Code assertion occurred.

Probable Cause / Recommended Action:

     The firmware or processor on the MUX has detected a firmware or hardware
     failure and was in an inconsistent state. The MUX has reset itself. This
     event does not require a corrective action if it does not reoccur. If this
     event does reoccur, report this event with its associated data to HP.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673600000000
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#213

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 584

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0D 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 0A  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 01 00 2C   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED B0   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF DC   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 214

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:55 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:55 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 214                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware warning.


Description of Error:

     Unknown hardware failure.

Probable Cause / Recommended Action:

     The MUX failed selftest but could not determine the exact cause. This
     event could occur if a fan failure was previously reported, but the fan
     was not replaced, and another fan failed. Check the fan cables and
     connectors, and check to see that both fans are operational.  Replace the
     fan assembly if it is found to be defective. If the fan is not defective,
     the cause may be another MUX component. Report this event with its
     associated data to HP.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673700000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#214

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 585

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0E 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 10  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FF C8   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 40   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<


                
                

Event 215

Event Details:

                          >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 01:33:00 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is MAJORWARNING(3).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 01:32:59 2001
Severity............: MAJORWARNING
Monitor.............: dm_fc_scsi_mux
Event #.............: 215                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : Hardware warning.


Description of Error:

     Fan module failed.

Probable Cause / Recommended Action:

     One of the two MUX cooling fans has failed. The fan may have something
     blocking it such as the fan cable. The fan may have an improperly
     installed or disconnected cable. The MUX will continue to operate as long
     as the remaining fan provides sufficient cooling. Check the fan cables and
     connectors. Check if both fans run and trouble shoot to find the exact
     cause. Replace the fan assembly if it is found to be defective.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8754b00000004
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#215

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 5 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 658

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0F 00   00 00 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 02  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 E9 A8   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 74   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 ED C8   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FF B4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 216

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:49 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Mar 21 00:32:48 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 216                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : FC external
     loopback test did not pass.


Description of Error:

     FC port A external loopback test Failed.

Probable Cause / Recommended Action:

     The FC loopback test has failed. Check for proper installation of the
     loopback cable. Check to make sure that the FC port cover connector was
     not used during the test instead of the loopback cable (the FC port cover
     does not provide loopback capability). Check the FC card for proper
     seating. Disconnect and reconnect the FC cable and perform the external
     loopback test again. If the problem persists, contact HP for replacement
     of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673000000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#216

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 577

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0A 00   00 16 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 03  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 EC 08   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 10   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 EE 00   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 01 00 68   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 217

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 00:32:49 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/8_12.8.0.255.0.5.0
 is >= 1.
Its current value is INFORMATION(1).

User Comments:

Test 1/23/01

Event data from monitor:

Event Time..........: Wed Mar 21 00:32:49 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 217                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 8/12.8.0.255.0.5.0 : FC external
     loopback test did not pass.


Description of Error:

     FC port B external loopback test Failed.

Probable Cause / Recommended Action:

     The FC loopback test has failed. Check for proper installation of the
     loopback cable. Check to make sure that the FC port cover connector was
     not used during the test instead of the loopback cable (the FC port cover
     does not provide loopback capability). Check the FC card for proper
     seating. Disconnect and reconnect the FC cable and perform the external
     loopback test again. If the problem persists, contact HP for replacement
     of the FC card.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab8673100000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#217

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location: WWN:20000060b02ae242
    Firmware Revision: 4jas
    Power ons since this event happened: 0
    Time since this event happened: 9 day; 4 hour; 34 minute 
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 579

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 01
          0x0000: 00 00 0B 00   00 16 5D 44   00 04 EE EE   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 05  

     Raw Inquiry Data:
          0x0000: 00 00 00 1B   41 2E 30 31   2E 30 30 00   64 6D 5F 66
          0x0010: 63 6D 6F 6E   00 69 5F 6D   75 78 00 35   00 00 00 28
          0x0020: 2F 76 61 72   2F 74 6D 70   2F 64 6D 5F   66 63 5F 73
          0x0030: 00 00 00 3C   00 00 00 02   00 00 00 3C   00 00 00 01
          0x0040: 40 01 DD 35   00 00 00 21   00 05 00 00   00 00 00 02
          0x0050: 00 00 00 0B   40 01 EC 08   40 01 DD A0   76 00 33 61
          0x0060: 40 00 FE 10   00 00 00 21   00 05 00 00   00 00 00 02
          0x0070: 00 00 00 0B   40 01 EE 00   40 01 E3 E8   00 00 00 47
          0x0080: 00 00 00 00   00 00 00 08   40 01 DD BD   00 00 00 21
          0x0090: 00 05 00 00   00 00 00 02   00 00 00 0B   40 01 DD E8
          0x00A0: 40 01 DE 30   73 69 5F 6D   40 00 FD D4   00 00 00 49


>---------- End Event Monitoring Service Event Notification ----------<

                
                

Event 219

Event Details:

                >------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Mar 21 13:24:52 2001

hprdstl6 sent Event Monitor notification information:

/connectivity/events/multiplexors/FC_SCSI_mux/10_12.8.0.255.0.4.0
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Mar 21 13:24:52 2001
Severity............: INFORMATION
Monitor.............: dm_fc_scsi_mux
Event #.............: 219                 
System..............: hprdstl6.rose.hp.com

Summary:
     Multiplexor (MUX) at hardware path 10/12.8.0.255.0.4.0 : Hardware warning.


Description of Error:

     FC SCSI MUX has started responding.

Probable Cause / Recommended Action:

     The MUX has entered the online condition due one of many possible causes. 
     The MUX may have powered up.  The MUX may have been connected or
     re-connected to the Fibre Channel network.  The MUX may have reset itself
     due to a network event.  A problem may have existed in the Fibre Channel
     network and now does not exist. The MUX may have had firmware with date
     code 3810 or earlier, replaced by newer firmware. After download with
     newer firmware, the MUX has the capability to handle polling by this
     monitor. 

     Normally the MUX and I/O operations will recover automatically from reset.
     No action is required. 

     This event has the same severity as MUX not responding event so that when
     one event appears, so can the other.

Additional Event Data: 
     System IP Address...: 15.8.135.196
     Event Id............: 0x3ab91c2400000002
     Monitor Version.....: B.01.01
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_dm_fc_scsi_mux.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: 9000/831 
          EMS Version.....................: A.03.20 
          STM Version.....................: A.26.00 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/dm_fc_scsi_mux.htm#219

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data: 
     FC Path 1...................: 8/12.8.0.255.0.5.0
     FC Path 2...................: 10/12.8.0.255.0.4.0
     World Wide Name.............: 0x20000060b02ae242
     Product Number..............: HP A3308

Product/Device Information:

    World Wide Name: 0x20000060-0xB02AE242
    MUX Location:
    Firmware Revision (Not Available):
 
    Each path, for which this event gets generated, will have this same
    duplicate event number : 988

Manager-Specific Information: 

     Raw Manager Data:
          0x0000: 00 02
          0x0000: 00 00 00 02  


>---------- End Event Monitoring Service Event Notification ----------<
                
                

Top of Page

/ Diagnostics HOME


URL: http://docs.hp.com/hpux/onlinedocs/diag/ems/dm_fc_scsi_mux.htm