Monitor Description | Configuration Files
Monitor Description
The Corrected Platform Error (CPE) monitor will run on an IPF system and monitors the CPEs logged by the system except Memory errors. The Memory monitor will processor the Memory-related CPEs.
The monitor is launched automatically when the system is started.
Release HistoryJune 2003 Release HP-UX 11i v2.0 (11.23)
Supported Products
All IPF systems.Special Requirements
HP-UX 11.23 or later.
Resource Path
Event monitoring: /system/events/cpe
Status monitoring: NonePSM State Control
The monitor does not support automatic state control.
Monitor Name
/usr/sbin/stm/uut/bin/tools/monitor/cpe_em
Configuration Files
Startup Configuration File (.sapcfg)File name: /var/stm/config/tools/monitor/cpe_em.sapcfg
Default values are standard.
Monitor Configuration File (.cfg)File name: /var/stm/config/tools/monitor/cpe_em.cfg
Default values:
POLL_INTERVAL 60 minutes PSM Configuration File (.psmcfg)
File name: /var/stm/config/tools/monitor/cpe_em.psmcfg
Default values:
PSM Resource Name None State Handling N/A Down State Handling N/A