EMS Hardware Monitors (logo)

Core Hardware Monitor for IA-64 Systems (ia64_corehw)


Monitor Description | Configuration Files


Monitor Description

The Core Hardware monitor will run on an IA-64 system and monitors hardware errors logged by various sensors on the system to the System Event Log (SEL). On the non-cellualr systems, the monitor will report the following errors from the SEL:

On cellualr systems, these errors will be reported to the Forward Progress Log (FPL). The monitor will make these available to the FPL Monitor (fpl_em) for further processing.

On HP-PA systems, the monitor will receive the PCI error data and make it available to the FPL monitor (fpl_em) for further processing.

The monitor is launched automatically when the system is started.

Release History

August 2001 Release (Support Plus the SPU correctable error)

June 2001 Release: Initial release

Supported Products

HP-PA and IPF systems.

Special Requirements

HP-UX 11.22 or later for IPF systems.

HP-UX 11.11 for HP-PA systems.

Resource Path

Event Monitoring : /system/events/ia64_corehw/core_hw
State Monitoring : None

Monitor Name

/usr/sbin/stm/uut/bin/tools/monitor/ia64_corehw

PSM State Control

The monitor does not support automatic state control.


Configuration Files

Startup Configuration File (.sapcfg)

File name: /var/stm/config/tools/monitor/ia64_corehw.sapcfg

Default values are standard. entries.

Monitor Configuration File (.cfg)

File name: /var/stm/config/tools/monitor/ia64_corehw.cfg

Default values:

POLL_INTERVAL 15 (seconds)
TIMEOUT 800 (milliseconds)
 RETRY_COUNT 4
 TEMPERATURE_LEVEL 2
 FAN_LEVEL 2
SENSOR_RESCAN_INTERVAL 485 (minutes)
 COMMAND "/usr/sbin/reboot -qh"
WATCHDOG_COMMAND "No_Action"

PSM Configuration File

File name: /var/stm/config/tools/monitor/ia64_corehw.psmcfg

Default values:

PSM Resource Name None
State Handling N/A
Down State Handling N/A

Top of Page / Diagnostics HOME


URL: http://docs.hp.com/hpux/onlinedocs/diag/ems/emd_ia64core.htm