Event 101
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Problem Description:
The device has been added to the set of devices being monitored by this monitor.- Probable Cause / Recommended Action:
The device was removed from the system, has stopped responding to the system or it has been
replaced with a device that is not supported by this monitor. Replace the disk drive.
Event 103
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Test event.
- Problem Description:
This is a test message from the monitor to test the communication path from the monitor to the notification mechanism.- Probable Cause / Recommended Action:
No action required.
Event 111
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Disk Fault.
- Problem Description:
The disk drive has a configuration error or an unsupported link.- Probable Cause / Recommended Action:
Replace the disk drive.
Event 112
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Problem Description:
The disk drive is missing.- Probable Cause / Recommended Action:
Install a disk drive or blank.Event 113
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Problem Description: The disk drive was removed while locked.
- Probable Cause / Recommended Action:
Clear the software lock before removing the disk drive.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Disk Fault.
- Problem Description: The disk drive has a link A rate error.
- Probable Cause / Recommended Action: Spin the disk drive up or down.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Disk Fault.
- Problem Description: The disk drive has a link B rate error.
- Probable Cause / Recommended Action: Spin the disk drive up or down.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Power Supply Fault.
- Problem Description: The power supply has no AC input.
- Probable Cause / Recommended Action: Check the AC power to the supply.
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Power Supply Fault.
- Problem Description: The power supply has been removed.
- Probable Cause / Recommended Action:
Install a power supply immediately. Shutdown is imminent.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Power Supply Fault.
- Problem Description: The power supply has load balance error.
- Probable Cause / Recommended Action:
Replace the power supply now.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description:
The fan speed is slow.- Probable Cause / Recommended Action: Replace the fan soon.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description: A fan speed failure occurred.
- Probable Cause / Recommended Action: Replace the fan now.
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description: The fan has stopped.
- Probable Cause / Recommended Action: Replace the fan now.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description: Fan status alert.
- Probable Cause / Recommended Action: Contact support
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description: The Fan is missing.
- Probable Cause / Recommended Action:
Install a new fan.
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Fan Fault.
- Problem Description: No fans are installed.
- Probable Cause / Recommended Action: Install a fan immediately.Shutdown is imminent.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Temperature Too High.
- Problem Description: The temperature sensor indicates a high temperature alert.
- Probable Cause / Recommended Action:
Check for an empty bay or check the air temperature.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Temperature Too High.
- Problem Description: The temperature sensor indicates a high temperature error.
- Probable Cause / Recommended Action: Check for an empty bay or check the air temperature.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Temperature Too Low.
- Problem Description: The temperature sensor indicates a low temperature alert.
- Probable Cause / Recommended Action: Check the air temperature.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Temperature Too Low.
- Problem Description: The temperature sensor indicates a low temperature error.
- Probable Cause / Recommended Action: Check the air temperature.
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Temperature Alert.
- Problem Description: The limits have been exceeded on the temperature sensor.
- Probable Cause / Recommended Action: Shutdown is imminent.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Transceiver Fault.
- Problem Description: An unsupported warning exists on the transceiver.
- Probable Cause / Recommended Action: Replace the transceiver.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Transceiver Fault.
- Problem Description: The transceiver lost signal.
- Probable Cause / Recommended Action: Check the cabling.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Transceiver Fault.
- Problem Description: The transceiver has a fault.
- Probable Cause / Recommended Action: Check the transceiver or cabling.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Transceiver Fault.
- Problem Description: The transceiver has has been removed.
- Probable Cause / Recommended Action: Install the transceiver .
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Transceiver Fault.
- Problem Description: The transceiver has invalid character.
- Probable Cause / Recommended Action: Check the module.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: High Voltage.
- Problem Description: A high voltage alert has occurred.
- Probable Cause / Recommended Action: Replace the power supply soon.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: High Voltage.
- Problem Description: A high voltage error has occurred.
- Probable Cause / Recommended Action: Replace the power supply now.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Low Voltage.
- Problem Description: A low voltage alert has occurred.
- Probable Cause / Recommended Action: Replace the power supply soon.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Low Voltage.
- Problem Description: A low voltage error has occurred.
- Probable Cause / Recommended Action: Replace the power supply now.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: High Current.
- Problem Description: A high current alert has occurred.
- Probable Cause / Recommended Action:Replace the power supply soon.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: High Current.
- Problem Description: A high current error has occurred.
- Probable Cause / Recommended Action: Replace the power supply now.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Backplane Fault.
- Problem Description: The NVRAM read is invalid.
- Probable Cause / Recommended Action: Automatic recovery is initiated.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Backplane Fault.
- Problem Description: The NVRAM write has failed.
- Probable Cause / Recommended Action: Replace the NVRAM.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Backplane Fault.
- Problem Description: The NVRAM is unreadable.
- Probable Cause / Recommended Action: Initialize or replace the NVRAM.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: Backplane Fault.
- Problem Description: The NVRAM is blank.
- Probable Cause / Recommended Action: Initialize the NVRAM.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault.
- Problem Description: An unsupported warning exists.
- Probable Cause / Recommended Action: Replace the I/O module.
- Severity: SERIOUS
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault.
- Problem Description: A communication error has occurred.
- Probable Cause / Recommended Action: Reset or replace the I/O module
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault.
- Problem Description: The NVRAM read is invalid.
- Probable Cause / Recommended Action: Automatic recovery is initiated.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault.
- Problem Description: The NVRAM write has failed.
- Probable Cause / Recommended Action: Replace the NVRAM.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault
- Problem Description: The NVRAM is unreadable.
- Probable Cause / Recommended Action: Initialize or replace the NVRAM.
- Severity: MINOR_WARNING
- Event Summary: Enclosure at hardware path 8/12.8.0.5.0.0.0: I/O Module Fault
- Problem Description: The I/O module has been removed.
- Probable Cause / Recommended Action: Initialize the I/O module.