EMS Hardware Monitors (logo)

High-Availability Disk Array Monitor (Events)

Event 1

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:14 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:14 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 1                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Soft
     SCSI error


Description of Error:

     This code indicates that an abnormal SCSI bus or disk drive event was
     detected.  A retry of the operation cleared the condition. (SP Event Code
     0x801)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef27200000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef27100000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#1

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   01 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   01 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08010000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0801
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x801
          This code indicates that an abnormal SCSI bus or disk drive event was
          detected.  A retry of the operation cleared the condition.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 2

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:17 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:17 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 2                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Illegal SCSI Bus interrupt


Description of Error:

     An inconsistent interrupt situation has been detected on the SP
     (storage-control processor).  (SP Event Code 0x802)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef27500000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef27400000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#2

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   02 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   02 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08020000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0802
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x802
          An inconsistent interrupt situation has been detected on the SP
          (storage-control processor).

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 3

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:20 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:20 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 3                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Recommend Disk Replacement


Description of Error:

     This disk CRU has sent status to the SP (storage-control processor)
     indicating that it believes it may be susceptible to a fault in the near
     future.  (SP Event Code 0x803)   

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef27800000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef27700000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#3

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   03 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   03 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08030000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0803
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x803
          This disk CRU has sent status to the SP (storage-control processor)
          indicating that it believes it may be susceptible to a fault in the
          near future.  We recommend replacing the drive.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 4

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:23 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:23 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 4                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Single
     Bit Error


Description of Error:

     The SP's tolerance level for single bit errors in the write cache has been
     exceeded.  (SP Event Code 0x804)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef27b00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef27b00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#4

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   04 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   04 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08040000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0804
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x804
          This SP (storage-control processor) has experienced excessive single
          bit errors in the write cache.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 5

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:26 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:26 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 5                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Single
     Bit Error


Description of Error:

     The SP's tolerance level for single bit errors in the read cache has been
     exceeded.  (SP Event Code 0x805)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef27e00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef27e00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#5

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   05 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   05 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08050000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0805
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x805
          This SP (storage-control processor) has experienced excessive single
          bit errors in the read cache.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 6

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:29 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:29 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 6                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Soft
     Media Error


Description of Error:

     This disk CRU has reported a media defect which was successfully cleared
     by the SP (storage-control processor).  (SP Event Code 0x820)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef28100000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef28100000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#6

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   20 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   20 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08200000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0820
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x820
          This disk CRU has reported a media defect which was successfully
          cleared by the SP (storage-control processor).

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 7

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:32 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:32 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 7                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Disk
     Sector Invalidated


Description of Error:

     The LUN that owns this disk CRU encountered a condition which required the
     firmware to invalidate a sector on the unit.  The firmware did this to
     ensure that incorrect data is not returned to the host in the future. (SP
     Event Code 0x840)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef28400000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef28400000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#7

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   40 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   40 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08400000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0840
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x840
          The LUN that owns this disk CRU encountered a condition which
          required the firmware to invalidate a sector on the unit.  The
          firmware did this to ensure that incorrect data is not returned to
          the host in the future.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 8

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:35 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:35 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 8                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Enclosure State Change


Description of Error:

     The SP detected that the DPE enclosure changed state. (SP Event Code
     0x850)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef28700000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef28700000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#8

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   50 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   50 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08500000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0850
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x850
          This SP (storage-control processor) has detected a state change in a
          DPE enclosure.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 9

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:38 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:38 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 9                    
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Enclosure Address Error


Description of Error:

     The SP detected that a DPE enclosure has an invalid address.  Enclosure
     chain shunted prior to failing enclosure.  (SP Event Code 0x851)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef28a00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef28a00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#9

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   51 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   51 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08510000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0851
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x851
          This SP (storage-control processor) has detected an invalid address
          in a DPE enclosure.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 10

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:42 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:41 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 10                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Enclosure Duplicate Address Error


Description of Error:

     The SP detected that two or more DPE enclosures have the same address.
     Enclosure chain shunted prior to failing enclosure.  (SP Event Code 0x852)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef28d00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef28d00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#10

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 08   52 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 08   52 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x08520000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0852
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x852
          This SP (storage-control processor) has detected an addressconflict
          between two or more DPE enclosures.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 20

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:45 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:44 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 20                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Hard
     SCSI error


Description of Error:

     An abnormal SCSI bus or disk drive event was detected and could not be
     cleared through retry operations.  (SP Event Code 0x901)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef29000000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef29000000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#20

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   01 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   01 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09010000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0901
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x901
          An abnormal SCSI bus or disk drive event was detected and could not
          be cleared through retry operations.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 21

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:15:48 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:15:47 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 21                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Fan
     Removed


Description of Error:

     A fan module has been shutdown or removed from the system. (SP Event Code
     0x903)

Probable Cause / Recommended Action:

     Fan pack has been opened for longer than 2 minutes, or fan pack has failed
     and shudown due to multiple fan failures.  Check to insure fan pack is
     fully closed.  Check "REPLACE LED", if lit replace the fan module.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef29300000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef29300000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#21

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   03 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   03 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09030000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0903
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x903
          A fan module has been shutdown or removed from the system.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 22

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:03 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:03 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 22                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      VSC
     Removed


Description of Error:

     A VSC module has been shutdown or removed from the system. (SP Event Code
     0x904)

Probable Cause / Recommended Action:

     A power supply unit (voltage semi-regulated converter (VSC)) has failed or
     has been removed for replacement.  Open fan pack and check VSC Service
     LED's.  Replace the VSC with the "REPLACE LED" indicator on.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2a300000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef29600000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#22

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   04 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   04 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09040000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0904
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x904
          A VSC module has been shutdown or removed from the system.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 23

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:19 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:19 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 23                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Chassis Overtemperature


Description of Error:

     A chassis overtemperature condition has been detected, the SP
     (storage-control processor) will attempt corrective action. (SP Event Code
     0x905)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b300000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef29900000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#23

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   05 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   05 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09050000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0905
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x905
          A chassis overtemperature condition has been detected, the SP
          (storage-control processor) will attempt corrective action.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 24

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:19 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:19 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 24                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Unit
     Shutdown


Description of Error:

     The Unit, which this drive is a member of, has been shutdown and can no
     longer be accessed by the host.  (SP Event Code 0x906)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b300000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef29c00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#24

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   06 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   06 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09060000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0906
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x906
          The Unit, which this drive is a member of, has been shutdown and can
          no longer be accessed by the host.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 25

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:20 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:20 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 25                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Controller Firmware Panic


Description of Error:

     This SP (storage-control processor)'s firmware encountered a situation
     from which there was no reliable execution other than to reload itself
     from from disk and restart.  This message is logged once the restarted
     session completes its initialization.  (SP Event Code 0x907)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b400000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2a000000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#25

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   07 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   07 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09070000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0907
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x907
          This SP (storage-control processor)'s firmware encountered a
          situation from which there was no reliable execution other than to
          reload itself from disk and restart.  This message is logged once the
          restarted session completes its initialization.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 26

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:20 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:20 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 26                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Hardware fault - Cache disabling


Description of Error:

     Some hardware condition has caused the SP (storage-control processor) to
     disable the cache.  (SP Event Code 0x908)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b400000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2a300000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#26

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   08 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   08 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09080000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0908
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x908
          Some hardware condition has caused the SP (storage-control processor)
          to disable the cache.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 27

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:21 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:21 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 27                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Cache
     dump failed


Description of Error:

     The SP (storage-control processor) cannot safely dump the cache to disk.  
     This will usually be caused by one or more of the cache dump disks being
     missing or failed.  (SP Event Code 0x909)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b500000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2a600000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#27

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   09 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   09 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09090000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0909
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x909
          The SP (storage-control processor) cannot safely dump the cache to
          disk.  This will usually be caused by one or more of the cache dump
          disks being missing or failed.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 28

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:22 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:21 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 28                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Assign
     fails - Cache dirty unit


Description of Error:

     The SP (storage-control processor) cannot assign this unit, because it is
     marked as having cached data outstanding, and the SP has no access to the
     data.  (SP Event Code 0x90A)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b500000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2a900000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#28

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0A 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0A 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090A0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090A
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90A
          The SP (storage-control processor) cannot assign this unit, because
          it is marked as having cached data outstanding, and the SP has no
          access to the data.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 29

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:22 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:22 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 29                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Controller cannot initialize cache


Description of Error:

     There was some hardware or software failure which occured when the SP
     (storage-control processor) attempted to initialize a new cache image. (SP
     Event Code 0x90B)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b600000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2ac00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#29

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0B 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0B 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090B0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090B
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90B
          There was some hardware or software failure which occured when the SP
          (storage-control processor) attempted to initialize a new cache
          image.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 30

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:23 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:22 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 30                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Cache
     image exceeds memory size


Description of Error:

     This SP (storage-control processor) is incapable of loading the saved
     cache data image due to insufficient cache memory size. (SP Event Code
     0x90C)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b600000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2af00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#30

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0C 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0C 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090C0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090C
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90C
          This SP (storage-control processor) is incapable of loading the saved
          cache data image due to insufficient cache memory size.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 31

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:23 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:23 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 31                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      BBU
     Removed


Description of Error:

     The BBU in this system has failed or been removed.  (SP Event Code 0x90D)

Probable Cause / Recommended Action:

     The Battery Backup Unit (BBU) has been removed or has failed.  Check for
     presence of BBU.  If present replace if "REPLACE LED" indicator is on.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2b700000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2b200000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#31

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0D 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0D 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090D0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090D
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90D
          The BBU in this system has failed or been removed.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 32

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:39 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:38 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 32                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      BBU
     Failed


Description of Error:

     The BBU in this system has failed its internal selftest. (SP Event Code
     0x90E)

Probable Cause / Recommended Action:

     The Battery Backup Unit (BBU) has failed its internal self-test. Replace
     BBU with device power on.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2c600000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2b500000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#32

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0E 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0E 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090E0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090E
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90E
          The BBU in this system has failed its internal selftest.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 33

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:54 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:54 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 33                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Cache
     Recovered with Errors


Description of Error:

     The attempted cache recovery on this SP (storage-control processor)
     recovered the dirty cache pages for some, but not all, of its dirty units.
     (SP Event Code 0x90F)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d600000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2b800000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#33

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   0F 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   0F 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x090F0000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x090F
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x90F
          The attempted cache recovery on this SP (storage-control processor)
          recovered the dirty cache pages for some, but not all, of its dirty
          units.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 34

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:55 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:54 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 34                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Cache
     Recovery Failed


Description of Error:

     The attempted cache recovery on this SP (storage-control processor) failed
     to recover the pages for any of its cache dirty units. (SP Event Code
     0x910)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d600000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2bb00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#34

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   10 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   10 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09100000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0910
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x910
          The attempted cache recovery on this SP (storage-control processor)
          failed to recover the pages for any of its cache dirty units.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 35

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:55 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:55 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 35                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Hard
     Media Error


Description of Error:

     This disk CRU has reported a media defect which could not be successfully
     cleared by the SP (storage-control processor).  This is a hard media
     error.  (SP Event Code 0x920)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d700000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2be00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#35

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   20 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   20 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09200000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0920
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x920
          This disk CRU has reported a media defect which could not be
          successfully cleared by the SP (storage-control processor).  This is
          a hard media error.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 36

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:56 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:56 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 36                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Host
     vault load failed


Description of Error:

     The SP (storage-control processor) encountered multiple errors while
     attempting to load the cache image from disk.  This message may indicate
     multiple drive failures.  (SP Event Code 0x921)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d800000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2c100000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#36

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   21 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   21 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09210000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0921
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x921
          The SP (storage-control processor) encountered multiple errors while
          attempting to load the cache image from disk.  This message may
          indicate multiple drive failures.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 37

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:57 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:56 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 37                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Host
     vault load inconsistent


Description of Error:

     The SP (storage-control processor) found the cache image on disk to have
     inconsistent data.  This may indicate a failure or abort of the cache
     dump.  (SP Event Code 0x922)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d800000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2c500000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#37

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   22 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   22 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09220000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0922
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x922
          The SP (storage-control processor) found the cache image on disk to
          have inconsistent data.  This may indicate a failure or abort of the
          cache dump.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 38

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:57 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:57 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 38                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Host
     vault load failed bitmap ok


Description of Error:

     The SP (storage-control processor) successfully read the control portion
     of the cache image on disk, but found the data portion to be incomplete.  
     This means that a failure or abort occurred during the cache dump. (SP
     Event Code 0x923)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2d900000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2c800000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#38

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   23 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   23 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09230000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0923
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x923
          The SP (storage-control processor) successfully read the control
          portion of the cache image on disk, but found the data portion to be
          incomplete.  This means that a failure or abort occurred during the
          cache dump.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 39

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:58 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:57 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 39                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Host
     vault disks scrambled


Description of Error:

     The SP (storage-control processor) found the vault drives containing the
     cache image to be in different order than when the cache image was dumped
     to disk.  The drives must be restored to their original order before the
     SP can load the cache image.  (SP Event Code 0x924)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2da00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2cb00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#39

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   24 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   24 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09240000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0924
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x924
          The SP (storage-control processor) found the vault drives containing
          the cache image to be in different order than when the cache image
          was dumped to disk.  The drives must be restored to their original
          order before the SP can load the cache image.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 40

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:58 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:58 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 40                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Single
     Board Cache - need PROM update


Description of Error:

     This SP (storage-control processor), which is operating in non-mirrored
     caching mode, has too low a PROM revision level.  Write Caching cannot be
     enabled.  (SP Event Code 0x925)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2da00000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2ce00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#40

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   25 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   25 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09250000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0925
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x925
          This SP (storage-control processor), which is operating in
          non-mirrored caching mode, has too low a PROM revision level.  Write
          Caching cannot be enabled.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 41

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:16:59 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:59 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 41                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      RAID-3
     Unit, Cannot Assign - No Memory


Description of Error:

     A RAID-3 LUN cannot be enabled because memory allocated for RAID-3
     processing is not available (that is, the memory has been removed or
     reconfigured).  (SP Event Code 0x926)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2db00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2d100000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#41

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   26 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   26 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09260000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0926
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x926
          A RAID-3 LUN cannot be enabled because memory allocated for RAID-3
          processing is not available (that is, the memory has been removed or
          reconfigured).

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 42

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:00 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:16:59 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 42                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Old
     RAID-3, Can't Assign


Description of Error:

     The revision of LIC you are running does not support "old" (pre-Revision
     9.X) RAID-3 LUNs.  To use the new RAID-3, you must use the current
     revision of LIC to unbind the LUN and rebind it as a RAID-3 LUN with
     RAID-3 memory.  (SP Event Code 0x927)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2db00000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2d400000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#42

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   27 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   27 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09270000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0927
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x927
          This LUN is bound at an unsupported RAID-3 revision level.  

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 43

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:00 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:00 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 43                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      RAID-3
     Initialization Failure - No memory


Description of Error:

     No RAID-3 LUNs can be enabled because memory allocated for RAID-3
     processing is not abailable, (that is, the memory has been removed or
     reconfigured).  (SP Event Code 0x928)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2dc00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2d700000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#43

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   28 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   28 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09280000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0928
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x928
          No RAID-3 LUNs can be enabled because memory allocated for RAID-3
          processing is not abailable, (that is, the memory has been removed or
          reconfigured).

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 44

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:01 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:01 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 44                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Front
     End Fibre Link Down


Description of Error:

     The front end fibre link is down.  (SP Event Code 0x929)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2dd00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2da00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#44

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   29 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   29 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09290000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0929
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x929
          The front end fibre link is down.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 45

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:02 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:02 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 45                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card Write Protected While Active


Description of Error:

     The PCMCIA (write-cache memory) card is write protected.  (SP Event Code
     0x930)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2de00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2dd00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#45

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   30 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   30 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09300000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0930
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x930
          The PCMCIA (write-cache memory) card is write protected.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 46

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:05 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:05 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 46                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card Battery Failed


Description of Error:

     The PCMCIA (write-cache memory) card's battery failed.  

Probable Cause / Recommended Action:

     Replace the battery.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2e100000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2e000000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#46

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   31 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   31 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09310000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0931
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x931
          The PCMCIA (write-cache memory) card's battery failed.  You must
          replace the battery.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 47

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:08 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:08 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 47                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card Absent or Inserted Incorrectly


Description of Error:

     The PCMCIA (write-cache memory) card is not present or was inserted
     incorrectly.  (SP Event Code 0x932)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2e400000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2e300000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#47

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   32 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   32 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09320000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0932
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x932
          The PCMCIA (write-cache memory) card is not present or was inserted
          incorrectly.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 48

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:11 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:11 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 48                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card POST Test Failed


Description of Error:

     The PCMCIA (write-cache memory) card failed its power up (POST) test. The
     SP (storage-control processor) disabled storage-system write caching Power
     down the storage system, replace the card, and power up the storage
     system.  (SP Event Code 0x933)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2e700000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2e700000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#48

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   33 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   33 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09330000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0933
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x933
          The PCMCIA (write-cache memory) card failed its power up (POST) test.
           The SP (storage-control processor) disabled storage-system write
          caching.  Power down the storage system, replace the card, and power
          up the storage system.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 49

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:14 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:14 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 49                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card Doesn't Match Subsystem, Cache Date Locked


Description of Error:

     The PCMCIA (write-cache memory) card was used in a different storage
     system.  The SP (storage-control processor) has locked the card to prevent
     cache data from being overwritten.  You must either remove the card and
     install it in the correct storage system or clear the card. (SP Event Code
     0x934)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2ea00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2ea00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#49

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   34 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   34 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09340000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0934
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x934
          The PCMCIA (write-cache memory) card was used in a different storage
          system.  The SP (storage-control processor) has locked the card to
          prevent cache data from being overwritten.  You must either remove
          the card and install it in the correct storage system or clear the
          card.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 50

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:17 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:17 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 50                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card too small for currently configured write cache


Description of Error:

     The PCMCIA (write-cache memory) card's capacity is smaller than the
     specified size of the SP (storage-control processor)'s write cache.  The
     SP disabled storage-system write caching.  You must either respecify the
     write cache size to equal the card's capacity or install a card with a
     capacity that equals the specified size.  (SP Event Code 0x935)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2ed00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2ed00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#50

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   35 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   35 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09350000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0935
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x935
          The PCMCIA (write-cache memory) card's capacity is smaller than the
          specified size of the SP (storage-control processor)'s write cache.  
          The SP disabled storage-system write caching.  You must either
          respecify the write cache size to equal the card's capacity or
          install a card with a capacity that equals the specified size.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 51

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:20 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:20 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 51                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      PCMCIA
     Card Hardware Failure


Description of Error:

     The SP (storage-control processor) encountered a hardware failure  while
     trying to write to the SP.  The SP has disabled write caching. (SP Event
     Code 0x936)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2f000000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2f000000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#51

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   36 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   36 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09360000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0936
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x936
          The SP (storage-control processor) encountered a hardware failure
          while trying to write to the SP.  The SP has disabled write caching.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 52

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:23 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:23 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 52                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Command Failed


Description of Error:

     A command failed for the reason explained in the extended status word. (SP
     Event Code 0x937)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2f300000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2f300000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#52

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 09   37 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 09   37 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x09370000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0937
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0x937
          A command failed for the reason explained in the extended status
          word.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 60

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:26 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:26 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 60                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Failed
     SCSI bus


Description of Error:

     A SCSI channel has failed; all drives on that bus are now inaccessable by
     the SP (storage-control processor).  (SP Event Code 0xA02)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2f600000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2f600000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#60

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   02 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   02 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A020000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A02
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA02
          A SCSI channel has failed; all drives on that bus are now
          inaccessible by the SP (storage-control processor).

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 61

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:30 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:29 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 61                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      NOVRAM
     Unititialized


Description of Error:

     The non-volatile memory on this SP (storage-control processor) was found
     to be uninitialized.  The SP has reinitialized the memory to its default
     state, and the SP will be functional after a reboot.  (SP Event Code
     0xA05)

Probable Cause / Recommended Action:

     Not available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2f900000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2f900000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#61

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   05 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   05 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A050000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A05
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA05
          The non-volatile memory on this SP (storage-control processor) was
          found to be uninitialized.  The SP has reinitialized the memory to
          its default state, and the SP will be functional after a reboot.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 62

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:33 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:32 2000
Severity............: CRITICAL
Monitor.............: ha_disk_array
Event #.............: 62                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Chassis Shutdown


Description of Error:

     An overtemperature situation could not be corrected.  All drives in the
     the chassis will be shut down.  (SP Event Code 0xA06)

Probable Cause / Recommended Action:

     The fan pack door has been opened for longer than 2 minutes or multiple
     fans have failed in the fan pack.  Insure the fan pack is closed.  If the
     "REPLACE LED" indicator is on, replace the fan pack.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef2fc00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2fc00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#62

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   06 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   06 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A060000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A06
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA06
          An overtemperature situation could not be corrected.  All drives in
          the chassis will be shut down.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 63

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:17:48 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Jul 26 07:17:48 2000
Severity............: CRITICAL
Monitor.............: ha_disk_array
Event #.............: 63                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Drive
     Failure


Description of Error:

     Disk drive has failed and can no longer be accessed. (SP Event Code 0xA07)

Probable Cause / Recommended Action:

     Replace the disk module.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef30c00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef2ff00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#63

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   07 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   07 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A070000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A07
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA07
          The disk drive has failed and can no longer be accessed.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 64

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:04 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:03 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 64                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Data
     Base Sync Error


Description of Error:

     The SP (storage-control processor) cannot determine the correct logical
     configuration of all units in this system.  Some units may be unusable.
     (SP Event Code 0xA08)

Probable Cause / Recommended Action:

     Not Available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef31b00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef30200000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#64

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   08 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   08 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A080000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A08
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA08
          The SP (storage-control processor) cannot determine the correct
          logical configuration of all units in this system.  Some units may be
          unusable.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 65

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:04 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:04 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 65                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Drive
     Too Small


Description of Error:

     A replacement drive has been inserted and does not have adequate capacity
     for a rebuild operation to begin.  (SP Event Code 0xA09)

Probable Cause / Recommended Action:

     Not Available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef31c00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef30500000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#65

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   09 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   09 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A090000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A09
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA09
          A replacement drive has been inserted and does not have adaquate
          capacity for a rebuild operation to begin.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 66

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:05 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:04 2000
Severity............: CRITICAL
Monitor.............: ha_disk_array
Event #.............: 66                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Peer
     Controller Removed


Description of Error:

     This SP (storage-control processor)'s peer is no longer responding to
     queries from this SP following a period of time where the peer was known
     present.  (SP Event Code 0xA11)

Probable Cause / Recommended Action:

     The peer Storage-control Processor (SP) has been removed or has failed.
     Replace the SP with the "Service LED" indicator on.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef31c00000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef30900000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#66

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   11 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   11 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A110000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A11
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA11
          This SP (storage-control processor)'s peer is no longer responding to
          queries from this SP following a period of time where the peer was
          known present.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 67

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:20 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:20 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 67                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      Cache
     Memory Hard Error


Description of Error:

     This SP (storage-control processor), which is operating in non-mirrored
     caching mode, has detected a nonrecoverable memory fault in the cache
     memory area.  (SP Event Code 0xA12)

Probable Cause / Recommended Action:

     Not Available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef32c00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef30c00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#67

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   12 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   12 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A120000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A12
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA12
          This SP (storage-control processor), which is operating in
          non-mirrored caching mode, has detected a nonrecoverable memory fault
          in the cache memory area.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 68

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:21 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is INFORMATION(1).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:21 2000
Severity............: INFORMATION
Monitor.............: ha_disk_array
Event #.............: 68                   
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      CRU
     Type Unsupported


Description of Error:

     This type of disk CRU is not supported by the current SP (storage-control
     processor) software.  The disk cannot be bound or used for for host I/O.  
     (SP Event Code 0xA13)

Probable Cause / Recommended Action:

     Not Available

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef32d00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef30f00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#68

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 01 0A   13 00 00 00   00 00 00 00
          0x0010: 5D 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 01 0A   13 00 00 00   00 00 00 00   5D 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x01
          Information Field Valid         : FALSE                
          Information Field               : 0x0A130000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x5D
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x01, RECOVERED ERROR, indicates that the last command
          completed successfully with some recovery action performed by the
          device.   

          The additional sense code and qualifier indicate that:  
          The Storage Processor is returning unsolicited sense data to the
          host, using the "Recovered Error Reporting" option for the disk
          array.  The actual condition being reported may not be a "Recovered
          Error" (the "Recovered Error" sense key has been used for
          compatibility reasons).  The "Event Code" (contained in the
          Information field of the sense data) reports the actual condition.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0A13
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000
      
     Event Code:  0xA13
          This type of disk CRU is not supported by the current SP
          (storage-control processor) software.  The disk cannot be bound or
          used for host I/O.

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

NOTE: Event numbers 80-110 have been renumbered consecutively to 110 - 140 in the December 2000 Release. Event numbers 100, 101 and 103 below are NEW events for December 2000 and after.

Event 100 (as of Dec. 2000)


Event 101 (as of Dec. 2000)


Event 103 (as of Dec. 2000)


NOTE: Event numbers 80-110 have been renumbered consecutively to 110 - 140.

Event 110

Event 111

Event 112

Event 113

Event 114

Event 115

Event 116

Event 117

Event 118

Event 119

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:18:56 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:18:56 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 119                  
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Hardware Error


Description of Error:

     A SP microcode update was attempted, but fewer than two database
     (microcode-storing) disks were in the cabinet at the time.  Two disks are
     required so that the new micrcode does not overwrite all copies of the
     current version, in case the new microcode does not load correctly.  If
     the new code does not load correctly, the SP will reload the old
     microcode. (Sense 04/3A/00)

Probable Cause / Recommended Action:

     Refer to Service Manual to determine the Database Drives. Insure at least
     two Data Base drives exist and retry the operation.  

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef35000000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef34f00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/scsi.htm#119

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 04 00   00 00 00 00   00 00 00 00
          0x0010: 3A 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 04 00   00 00 00 00   00 00 00 00   3A 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x04
          Information Field Valid         : FALSE                
          Information Field               : 0x00000000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x3A
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x04, HARDWARE ERROR, indicates that the device detected a
          nonrecoverable hardware failure (for example, controller failure,
          device failure, parity error, etc.) while performing the command or
          during a self test.
                        
          The combination of Additional Sense Code and Sense Qualifier (0x3A00)
          indicates: Medium not present.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0000
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 120

Event 121

Event 122

Event 123

Event 124

Event 125

Event 126

Event 127

Event 128

Event 129

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:21:16 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is SERIOUS(4).



Event data from monitor:

Event Time..........: Wed Jul 26 07:21:16 2000
Severity............: SERIOUS
Monitor.............: ha_disk_array
Event #.............: 129                  
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Illegal Request


Description of Error:

     The initiator (host) is attempting to download drive firmware without
     disabling the peer SP.  (Sense 05/27/00)

Probable Cause / Recommended Action:

     An operational peer SP exists in the array.  The array requires that the
     peer SP be disabled during drive firmware download operations. Disable the
     peer SP then retry the download operation.  WARINING: do NOT enable peer
     SP while drive firmware download operations are in progress. Doing so can
     interrupt the process, possibly causing drive failure and loss of data.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef3dc00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef36e00000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#129

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 05 00   00 00 00 00   00 00 00 00
          0x0010: 27 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 05 00   00 00 00 00   00 00 00 00   27 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x05
          Information Field Valid         : FALSE                
          Information Field               : 0x00000000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x27
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x05, ILLEGAL REQUEST, indicates that there was an illegal
          parameter in the command data block or in the additional parameters
          supplied as data for some commands (FORMAT UNIT, SEARCH DATA, etc.).  
          This sense key may also indicate that an invalid IDENTIFY message was
          received.
                        
          The combination of Additional Sense Code and Sense Qualifier (0x2700)
          indicates: Write protected.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0000
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 130

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Wed Jul 26 07:21:31 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/8_12.8.0.255.0.1
 is >= 1.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Wed Jul 26 07:21:31 2000
Severity............: MAJORWARNING
Monitor.............: ha_disk_array
Event #.............: 130                  
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 8/12.8.0.255.0.1.0 :      
     Illegal Request


Description of Error:

     The initiator (host) is performing a microcode download operation, but
     there are no disk drives to which the SP can appropriately install the
     microcode.  (Sense 05/3A/00)

Probable Cause / Recommended Action:

     The array contains no operational disk drives which are compatible with
     the firmware/microcode being downloaded.  The firmware does NOT need to be
     downloaded.  No further action is necessary.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x397ef3eb00000000
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          0x397ef37100000000
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#130

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Component Data:  
     Physical Device Path.......: 8/12.8.0.255.0.1
     Inquiry Vendor ID..........: DGC      
     Inquiry Product ID.........: C3400WDR5        
     Serial Number..............: hajj1
     Firmware Version...........: HP03
     Device Class...............: 13

Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: C3400 Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x00
     SCSI LUN..........: 0x00

I/O Log Event Data:  

     Driver Status Code..................: 0x00000000  
     Length of Logged Hardware Status....: 76 bytes.  
     Offset to Logged Manager Information: 76 bytes.  
     Length of Logged Manager Information: 34 bytes.  

Hardware Status:  

     Raw H/W Status:
          0x0000: 00 00 00 02   70 00 05 00   00 00 00 00   00 00 00 00
          0x0010: 3A 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   00 00 00 00   

     SCSI Status...: CHECK CONDITION (0x02)  
          Indicates that a contingent allegiance condition has occurred.  Any
          error, exception, or abnormal condition that causes sense data to be
          set will produce the CHECK CONDITION status.
      
SCSI Sense Data:  

     Undecoded Sense Data:
          0x0000: 70 00 05 00   00 00 00 00   00 00 00 00   3A 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0030: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0040: 00 00 00 00   00 00 00 00   
      
     SCSI Sense Data Fields:
          Error Code                      : 0x70
          Segment Number                  : 0x00
          Bit Fields:       
               Filemark                   : 0
               End-of-Medium              : 0
               Incorrect Length Indicator : 0
          Sense Key                       : 0x05
          Information Field Valid         : FALSE                
          Information Field               : 0x00000000
          Additional Sense Length         : 0
          Command Specific                : 0x00000000
          Additional Sense Code           : 0x3A
          Additional Sense Qualifier      : 0x00
          Field Replaceable Unit          : 0x00
          Sense Key Specific Data Valid   : FALSE                
          Sense Key Specific Data         : 0x00 0x00 0x00
                        
          Sense Key 0x05, ILLEGAL REQUEST, indicates that there was an illegal
          parameter in the command data block or in the additional parameters
          supplied as data for some commands (FORMAT UNIT, SEARCH DATA, etc.).  
          This sense key may also indicate that an invalid IDENTIFY message was
          received.
                        
          The combination of Additional Sense Code and Sense Qualifier (0x3A00)
          indicates: Medium not present.

     Detailed Disk Array SCSI Sense Data Fields:
          Event Code................: 0x0000
          CRU ......................: A0
          LUN.......................: 0x00
          Type of FRU...............: Disk Module
          Host SCSI ID..............: 0x00
          Backend SCSI ID...........: 0x00
          Extended Status ( 8-bits).: 0x00
          Extended Status (32-bits).: 0x00000000

SCSI Command Data Block:  (not present in log record)

Manager-Specific Information:  

     Raw Manager Data:
          0x0000: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0010: 00 00 00 00   00 00 00 00   00 00 00 00   00 00 00 00
          0x0020: 00 00

     Manager Specific Data Fields:       
          Data Residue...........: 0x00000000  
          Sense Status...........: 0x00000000  
          Request ID.............: 0x00000000  
          Additional I/O Status..: 0x00000000  
          BUSP Struct Pointer....: 0x00000000  
          Target Struct Pointer..: 0x00000000  
          LUN Struct Pointer.....: 0x00000000  
          Target ID..............: 0x00  
          LUN ID.................: 0x00  
          Sense Data Length......: 0x00  
          Tag....................: 0x00  
          Retry Count............: 0x00     


>---------- End Event Monitoring Service Event Notification ----------<

Event 131

Event 132

Event 133

Event 134

Event 135

Event 136

Event 137

Event 138

Event 139

Event 140

Event 200

Event Details:
Example:
>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Tue Sep  5 14:21:58 2000

hprdstl6 sent Event Monitor notification information:

/storage/events/disk_arrays/High_Availability/10_12.8.0.255.0.1
 is >= 1.
Its current value is CRITICAL(5).



Event data from monitor:

Event Time..........: Tue Sep  5 14:21:58 2000
Severity............: CRITICAL
Monitor.............: ha_disk_array
Event #.............: 200                  
System..............: hprdstl6.rose.hp.com

Summary:
     Storage array controller at hardware path 10/12.8.0.255.0.1.0 :      
     Device Failure


Description of Error:

     The device is not responding to I/O.

Probable Cause / Recommended Action:

     The device may have been powered off. Power it back on.

     Alternatively, one or both of the terminators on the SCSI bus may be
     missing. Install the terminators in their proper locations at the ends of
     the SCSI bus.

     Alternatively, the SCSI cable may have become detached from the device.
     Re-attach the cable.

     Alternatively, the SCSI cable may have failed. Replace it.

     Alternatively, the device may be in a state where it could not process
     this, or any, request. Cycle power to the device.

     Alternatively, there could be more than one device having the same address
     on the SCSI bus. Make all the addresses on the SCSI bus unique.

     Alternatively, the total length of all cable segments on the SCSI bus
     exceeds 25 meters. Replace one or more cable segments until the total
     length is less than this value.

     Alternatively, if all of the above fail to correct the problem, the device
     has experienced a hardware failure. Repair or replace it, as necessary.

Additional Event Data:  
     System IP Address...: 15.8.135.196
     Event Id............: 0x39b563f600000002
     Monitor Version.....: B.01.00
     Event Class.........: I/O
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ha_disk_array.clcfg  
     Client Configuration File Version...: A.01.00  
          Qualification criteria met.
               Number of events..: 1  
     Associated OS error log entry id(s):  
          None
     Additional System Data:
          System Model Number.............: 9000/831  
          OS Version......................: B.11.00  
          System Serial Number............: unavailable  
          System Software ID..............: 2012993918  
          EMS Version.....................: A.03.10  
          STM Version.....................: A.23.00  
     Latest information on this event:
          http://docs.hp.com/hpux/onlinedocs/diag/ems/ha_disk_array.htm#200

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v



Product/Device Identification Information:

     Logger ID.........: sdisk
     Product Identifier: High Availability Disk Array
     Product Qualifier.: DGCC3400WDR5
     SCSI Target ID....: 0x01
     SCSI LUN..........: 0x00


>---------- End Event Monitoring Service Event Notification ----------<

Events 100000-1nnnnn

Events 100000-1nnnnn are default SCSI Events. All are asynchronous. For a list of these events, see:


Top of Page / Diagnostics HOME


URL: http://docs.hp.com/hpux/onlinedocs/diag/ems/ems/ha_disk_array.htm