Event 110
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description:
The Redundant Power supply in slot 0/1 is removed from the device.- Probable Cause / Recommended Action:
Possible causes include:
Check the power supply and insert it into the power supply slot 0/1.
- The cable has been physically removed.
- Power supply cable needs to be changed.
Event 111
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description:
The Redundant Power supply in slot 0/1 is inserted in the device.- Probable Cause / Recommended Action:
No action required.Event 120
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description:
Fan Component in slot 0/1 from the device has been inserted.- Probable Cause / Recommended Action:
Possible Causes include:
The fan component has been physically removed. Insert the fan component into the ! Slot.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: Fan Component in slot 0/1 from the device has been inserted.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: The device UPS component from slot 0/1 has been removed.
- Probable Cause / Recommended Action:
Possible Causes include:
The device UPS component has been physically removed. Check the UPS component and insert it into the 0/1 slot.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: The device UPS component from slot 0/1 has been inserted.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: The Redundant Controller in slot 0/1 from the device has been removed.
- Probable Cause / Recommended Action:
Possible Causes include:
Insert / Reset the controller in the 0/1 slot.
- The Controller has been physically removed.
- The Controller has been reset.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: Redundant Controller in slot 0/1 from the device has been inserted.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: The Physical Drive at Bay 4 has been removed from the device.
- Probable Cause / Recommended Action:
Possible Causes include:
The Physical Drive has been physically removed. Insert the physical drive in Bay 4.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hot Plugs removed / inserted.
- Event Class: Array
- Problem Description: The Physical Drive at Bay 4 has been inserted in the device.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hardware failure.
- Event Class: Array
- Problem Description: Fan module at slot 0/1 is reporting a fault.
- Probable Cause / Recommended Action:
One of the fan modules in the slot 0/1 in the external storage device is reporting a failure. The controller may attempt to shut down power to the storage device and/or spin down the installed disk drives.
Check and contact your HP representative to check the fan module.
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hardware failure.
- Event Class: Array
- Problem Description: Fan module at slot 0/1 is reporting a degraded condition.
- Probable Cause / Recommended Action:
Fan module in the slot 0/1 in the external storage device is reporting a degraded condition.
Check and contact your HP representative to check the fan module.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Fan module is now operational.
- Event Class: Array
- Problem Description: Fan module at slot 0/1 is now operational.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Voltage Regulator Module (VRM) is removed.
- Event Class: Array
- Problem Description: Voltage Regulator Module (VRM) is removed.
- Probable Cause / Recommended Action:
VRM has been removed.
Check and replace the VRM in the slot.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Voltage Regulator Module (VRM) is inserted.
- Event Class: Array
- Problem Description: Voltage Regulator Module (VRM) is inserted.
- Probable Cause / Recommended Action: No action required.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Hardware failure.
- Event Class: Array
- Problem Description: Voltage Regulator Module (VRM) has failed.
- Probable Cause / Recommended Action:
VRM has been failed.
Contact your HP representative.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Voltage Regulator Module (VRM) is ok.
- Event Class: Array
- Problem Description: Voltage Regulator Module (VRM) is ok.
- Probable Cause / Recommended Action: No action required.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Temperature Limit Exceeded.
Internal Temperature at slot 0/1 has exceeded the preset limit.- Probable Cause / Recommended Action: Temperature limit exceeded.
Check the airflow, room temperature, and fans in and around the device.
- Severity: MAJORWARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Temperature Warning Level Reached. Internal Temperature at slot 0/1 is nearing the preset temperature limit.
- Probable Cause / Recommended Action: Temperature warning level reached. Check the airflow, room temperature, and fans in and around the device.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Temperature Warning Condition Removed. Previously existing temperature warning condition has been corrected.
- Probable Cause / Recommended Action: No action required.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Power supply at slot 0/1 has a fault.
- Probable Cause / Recommended Action: Check the power supply at slot 0/1.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Power Supply is now operational.
- Probable Cause / Recommended Action: No action required.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Chassis Door Open. The controller may attempt to shut down power to the storage device and/or spin down the installed disk drives.
- Probable Cause / Recommended Action: The chassis door is open. Check and close the door.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: Chassis Door Closed.
- Probable Cause / Recommended Action: No action required.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: AC power at slot 0/1 is indicating a Failure (UPS failure).
- Probable Cause / Recommended Action:
Possible causes include:
Contact your HP representative.
- AC power is not present
- There is a complete power failure
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Component State Change.
- Event Class: Array
- Problem Description: AC power at slot 0/1 is indicating Battery low.
- Probable Cause / Recommended Action: Recharge the battery.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Physical Drive Failure.
- Event Class: Array
- Problem Description: Physical Drive at Bay 4 has failed.
- Probable Cause / Recommended Action:
Possible causes include:
Insert the physical drive in Bay 0/1 if it has been removed.
- Physical Drive has been removed.
- Physical Drive has failed.
Contact your HP representative for a failed physical drive.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Logical volume 6 has its status changed.
- Probable Cause / Recommended Action: No action required.
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Logical volume 6 is in a failed state.
- Probable Cause / Recommended Action: The logical drive is in a failed state.
Action:
- Turn the entire system off. Remove and then insert all hard drives and controllers.
- Turn the system on.
- Contact Your HP representative for any failed drives.
- After the failed disks has been replaced, power cycle again.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Rebuild aborted due to Read error. The rebuild of the Replacement Drive at slot 0/1 was aborted because data could not be regenerated due to a drive read error.
- Probable Cause / Recommended Action: The rebuild of a replacement drive at slot 0/1 was aborted because data could not be regenerated due to a drive read error.
Contact your HP representative to check the drive at slot 0/1.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Rebuild aborted due to write error. The rebuild of the Replacement Drive at slot 0/1 was aborted because data could not be regenerated due to a drive write error.
- Probable Cause / Recommended Action: The rebuild of a replacement drive at slot 0/1 was aborted because a write command to the replacement drive did not successfully complete.
Contact your HP representative to check the drive at slot 0/1.
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Logical I/O Request – Fatal Error. A fatal error has been returned to the host on a read/write request from the logical drive slot 0/1.
- Probable Cause / Recommended Action: A fatal error has been returned to the host on a read/write request on 0/1 this volume.
Contact your HP representative to check the drive at slot 0/1.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Logical Drive state Changes.
- Event Class: Array
- Problem Description: Consistency Initialization Pass completed for Logical I/O request at slot 0/1.
- Probable Cause / Recommended Action: Consistency Initialization pass completed for logical drive 0/1.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: Redundant Operation Status Changed.
- Event Class: Array
- Problem Description: The device has been setup in a redundant controller configuration. The Redundant Operation Status of the controllers has changed. Current Slot Control: 0/1 Current Redundancy Mode: 1 Redundant Controller Status: 1 Redundant Failure Reason: 1
- Probable Cause / Recommended Action: No action required.
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: Fan module is reporting a fault.
- Probable Cause / Recommended Action: One of the fan modules in the external storage device is reporting a failure.
Possible cause:Recommended action:
- The fan module has been removed or is not installed properly.
- Check the fan module installation.
- If the problem persists, contact you HP support representative.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: Fan module is in Normal condition.
- Probable Cause / Recommended Action: No action required.
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: Temperature fault. Internal temperature is in CRITICAL state.
- Probable Cause / Recommended Action: Temperature limit exceeded. Check the airflow, room temperature, and fans in and around the device.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: Temperature fault. Internal temperature is in WARNING state.
- Probable Cause / Recommended Action: Temperature warning level reached. Check the airflow, room temperature, and fans in and around the device.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: Temperature condition NORMAL.
- Probable Cause / Recommended Action: No action required.
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: The power supply is reporting a fault.
- Probable Cause / Recommended Action:
Possible causes include:Recommended action:
- AC power is not present.
- There is a complete power failure.
- Contact you HP support representative.
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path 8/12.8.0.5.0.0.0: MSA30 events.
- Event Class: Array
- Problem Description: The power supply is in NORMAL condition.
- Probable Cause / Recommended Action: No action required.