HP Storage Works Modular SAN Array 60/70 Monitor (msamon_sas)
This document describes the event details of the msamon_sas monitor.
Note: Examples in the event details section represent the format and the type of event data output only. They may not be true events. Values in the system and device data may be imaginary.
Event 100
- Severity:INFORMATION
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Device added for monitoring.
- Problem Description: The enclosure has been added to the set of enclosures being monitored by this monitor.
- Probable Cause / Recommended Action:
The enclosure was added to the system or has started responding to the system. The /var/datm/data/os_decode_xref file was modified to add information indicating this device is now supported by this monitor. If the device is in the DOWN state and this monitor does not control setting the state of the device to UP (check by running the "/etc/opt/resmon/lbin/set_fixed -L" command), use the "/etc/opt/resmon/lbin/set_fixed -n <resource_name>" command to set the state of the device to UP.
Event 101
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Device removed from monitoring.
- Event Class: I/O
- Problem Description: The enclosure has been removed from the list of enclosures being monitored by this monitor.
- Probable Cause / Recommended Action: The enclosure was removed from the system, has stopped responding to the system or it has been replaced with a device that is not supported by this monitor. Run ioscan to determine the state and type of the device. Check the /var/stm/data/os_decode_xref for the information indicating which devices are supported by this monitor. Check other monitors to determine if they are now monitoring the device by running /etc/opt/resmon/lbin monconfig and the using the "Check monitoring" command.
Event 103
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Test event.
- Problem Description:
This is a test message from the monitor to test the communication path from the monitor to the notification mechanism.
- Probable Cause / Recommended Action:
No action required.
Event 201
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Power Failure.
- Event Class: I/O
- Problem Description: The power supply in slot A has faulted.
- Probable Cause / Recommended Action: The power supply has detected an internal failure. Check that the power supply is plugged in, and adequate power is going to the power supply. Inspect/verify the power supply.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 202
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Power Failure.
- Event Class: I/O
- Problem Description: The power supply in slot A is not receiving adequate AC power.
- Probable Cause / Recommended Action: The power supply has been unplugged, power has failed, or power is poor quality. Check that the power supply is plugged in, and adequate power is going to the power supply.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 203
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Power Failure
- Event Class: I/O
- Problem Description: The power supply in slot A is not receiving adequate DC power.
- Probable Cause / Recommended Action: The power supply has detected an internal failure. Check that the power supply is plugged in, and adequate power is going to the power supply. Inspect/verify the power supply.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 204
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Power Failure
- Event Class: I/O
- Problem Description: The power module in slot A is not installed.
- Probable Cause / Recommended Action: The power module has been removed or it is not installed. If the power module is removed please insert it back else no action is required.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 301
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Hardware Failure.
- Event Class: I/O
- Problem Description: The fan is not providing cooling.
- Probable Cause / Recommended Action: The fan has either failed or been turned off. Inspect or reset the fan. Do not remove a fan from an operating product until you have the replacement fan and are ready to install it. An empty slot will cause uneven cooling and eventual overheating.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 302
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Temperature Sensor.
- Event Class: I/O
- Problem Description: The Temperature at sensor 1 within the enclosure has exceeded the critical threshold.
- Probable Cause / Recommended Action: The current temperature of the temperature Element is 30 degrees. Check the airflow, room temperature, and fans on and around the enclosure.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 303
- Severity: MAJOR
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Temperature Sensor.
- Event Class: I/O
- Problem Description: The value of temperature sensor 1 within the enclosure has exceeded the warning threshold.
- Probable Cause / Recommended Action: The current temperature of the temperature Element is 30 degrees. Check the airflow, room temperature, and fans on and around the enclosure.
- Automated Recovery: None
- Event Generation Threshold: 1 occurrence
Event 304
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Temperature Sensor.
- Event Class: I/O
- Problem Description: The value of temperature sensor 1 within the enclosure has dropped below the low critical threshold.
- Probable Cause / Recommended Action: The current temperature of the temperature Element is 30 degrees. Check the airflow, room temperature, and fans on and around the enclosure.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 305
- Severity: MAJOR
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Temperature Sensor.
- Event Class: I/O
- Problem Description: The value of temperature sensor 1 within the enclosure has dropped below the low warning threshold.
- Probable Cause / Recommended Action: The current temperature of the temperature Element is 30 degrees. Check the airflow, room temperature, and fans on and around the enclosure.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 307
- Severity: INFORMATION
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Cooling fan not installed.
- Event Class: I/O
- Problem Description: The fan A is not installed.
- Probable Cause / Recommended Action: The fan has been removed or it is not installed. If the fan is removed please insert it back else no action is required.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 401
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Hardware Failure.
- Event Class: I/O
- Problem Description: The enclosure services controller 1 has failed.
- Probable Cause / Recommended Action: The enclosure services controller 1 has failed. Inspect/verify the controller card.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 402
- Severity: MAJOR
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Controller Not Installed.
- Event Class: I/O
- Problem Description:Enclosure Services Controller 1 is not installed.
- Probable Cause / Recommended Action: The enclosure services controller 1 may not be installed in the enclosure. This does not affect normal host communication or enclosure functionality. Inspect/verify the controller.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence
Event 404
- Severity: CRITICAL
- Event Summary: Enclosure at hardware path 64000/0xfa00/0x8: Hardware Failure.
- Event Class: I/O
- Problem Description: The enclosure services device is not responding.
- Probable Cause / Recommended Action: The enclosure services controller has failed or is no longer connected to the host. Check the connection, cables and controller card.
- Automated Recovery: None.
- Event Generation Threshold: 1 occurrence