The following list identifies all the SCSI-related events that may occur on any hardware monitor. The events are classified by the three elements of SCSI sense data:Some event numbers occur multiple times, but the event is subdivided by the values of the three elements.
- Sense Key ("Key")
- Additional Sense Code ("Code")
- Additional Sense Code Qualifier ("Qualifier")
This document covers releases of the Hardware Monitors from Feb 1999 to March 2000.
For later versions of STM/EMS, use: SCSI Events (June 2000 +)
Event 100001
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: - Code: - Qualifier: -
- Severity: Information
- Description: Successful completion of operation
- Cause: The device driver has successfully completed an I/O request.
- Action: No action is necessary.
Event 100001
- Key: - Code: - Qualifier: -
- Severity: Information
- Description: Successful completion of operation
- Cause: An attempt to search for data or prefetch data on a device was successful.
- Action: No action is necessary.
Event 100001
- Key: - Code: - Qualifier: -
- Severity: Information
- Description: Successful completion of operation
- Cause: The device driver has successfully completed an I/O request.
- Action: No action is necessary.
Event 100001
- Key: - Code: - Qualifier: -
- Severity: Information
- Description: Successful completion of operation
- Cause: A request to search for data on a device was successful.
- Action: No action is necessary.
Event 100001
- Key: 0x00 Code: 0x00 Qualifier: 0x00
- Severity: Information
- Description: Successful completion of operation
- Cause: The device driver has successfully completed an I/O request.
- Action: No action is necessary.
Event 100002
- Key: 0x06 Code: 0x48 Qualifier: 0x00
- Severity: Information
- Description: Successful completion of operation
- Cause: The device adapter assigned to the device has received an error message.
- Action: No action is necessary.
Event 100003
- Key: 0x06 Code: 0x53 Qualifier: 0x02
- Severity: Information
- Description: Successful completion of operation
- Cause: The media access door for the device has been locked to prevent removal of the medium.
- Action: No action is necessary.
Event 100004
- Key: 0x06 Code: 0x5a Qualifier: 0x00
- Severity: Information
- Description: Successful completion of operation
- Cause: The device has received an unspecified operator request, or an operator control has changed state.
- Action: No action is necessary.
Event 100005
- Key: 0x06 Code: 0x5a Qualifier: 0x01
- Severity: Information
- Description: Successful completion of operation
- Cause: The device has received an operator medium removal request.
- Action: Remove the medium from the device.
Event 100006
- Key: 0x06 Code: 0x5a Qualifier: 0x02
- Severity: Information
- Description: Successful completion of operation
- Cause: The operator of the device has switched on the write protect function.
- Action: No action is necessary.
Event 100007
- Key: 0x06 Code: 0x5a Qualifier: 0x03
- Severity: Information
- Description: Successful completion of operation
- Cause: The operator of the device has switched off the write protect function.
- Action: No action is necessary.
Event 100008
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x3a Qualifier: 0x00
- Severity: Information
- Description: Medium loaded or replaced
- Cause: The medium in the device has been loaded or replaced. A program had established a logical connection with the device at a time when no medium was present in it. An I/O operation was requested, then a medium was inserted.
Alternatively, the logical connection was established at a time when an unformatted medium was present in the device. This medium was removed and replaced with either the same or a different medium.- Action: No action is necessary.
Event 100008
- Key: 0x06 Code: 0x30 Qualifier: 0x01
- Severity: Information
- Description: Medium loaded or replaced
- Cause: The medium in the device has been loaded or replaced. A program had established a logical connection with the device at a time when no medium was present in it. An I/O operation was requested, then a medium was inserted.
Alternatively, the logical connection was established at a time when an unformatted medium was present in the device. This medium was removed and replaced with either the same or a different medium.- Action: No action is necessary.
Event 100008
- Key: 0x06 Code: 0x28 Qualifier: 0x00
- Severity: Information
- Description: Medium loaded or replaced
- Cause: The medium in the device has been loaded or replaced. A program had established a logical connection with the device at a time when no medium was present in it. An I/O operation was requested, then a medium was inserted.
Alternatively, the logical connection was established at a time when an unformatted medium was present in the device. This medium was removed and replaced with either the same or a different medium.- Action: No action is necessary.
Event 100009
- Key: 0x06 Code: 0x30 Qualifier: 0x02
- Severity: Information
- Description: Medium in device cannot be used
- Cause: The medium in the device is incompatible with the device.
- Action: Replace the medium with one that is compatible with the device.
Event 100010
- Key: 0x06 Code: 0x30 Qualifier: 0x03
- Severity: Information
- Description: Medium in device cannot be used
- Cause: The device driver was unsuccessful in processing an I/O request because the device has a cleaning cartridge inserted into its mechanism.
- Action: Remove the cleaning cartridge and replace it with a data cartridge.
Event 100011
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x27 Qualifier: 0x00
- Severity: Information
- Description: Medium in device cannot be used
- Cause: The device attempted to process a command that would write data to it, but was prevented from doing so because the medium was protected against that.
- Action: If the device is of a type whose medium can be write protected, and it is desired to write data to that device, remove the protection.
Alternatively, the device may have experienced a hardware failure. Repair or replace it, as necessary.Event 100011
- Key: Code: Qualifier:
- Severity: Information
- Description: Medium in device cannot be used
- Cause: The device attempted to process a command that would write data to it, but was prevented from doing so because the medium was protected against that.
- Action: If the device is of a type whose medium can be write protected, and it is desired to write data to that device, remove the protection.
Alternatively, the device may have experienced a hardware failure. Repair or replace it, as necessary.Event 100012
- Key: 0x06 Code: 0x51 Qualifier: 0x00
- Severity: Information
- Description: Medium in device cannot be used
- Cause: The optical device was unsuccessful in erasing the requested portion of its medium. The medium may be unusable.
- Action: The medium in the device is flawed. Replace the medium with a fresh one.
Event 100013
- Key: 0x00 Code: 0x00 Qualifier: 0x11
- Severity: Information
- Description: Audio compact disc operation in progress
- Cause: An audio compact disc is being played.
- Action: No action is necessary.
Event 100014
- Key: 0x00 Code: 0x00 Qualifier: 0x12
- Severity: Information
- Description: Audio compact disc operation in progress
- Cause: An audio compact disc which was playing, is now paused.
- Action: No action is necessary.
Event 100015
- Key: 0x00 Code: 0x00 Qualifier: 0x13
- Severity: Information
- Description: Audio compact disc operation in progress
- Cause: An audio compact disc which was playing, has now finished.
- Action: No action is necessary.
Event 100016
- Key: 0x00 Code: 0x00 Qualifier: 0x15
- Severity: Information
- Description: Audio compact disc operation in progress
- Cause: During an attempt to obtain the current audio status of a Compact Disc, the device reported that none was available to return.
- Action: No action is necessary.
Event 100017
- Key: 0x06 Code: 0x3f Qualifier: 0x00
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its operating conditions changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100018
- Key: 0x06 Code: 0x3f Qualifier: 0x01
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its microcode changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100019
- Key: 0x06 Code: 0x3f Qualifier: 0x02
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its operating definition changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100020
- Key: 0x06 Code: 0x3f Qualifier: 0x03
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its inquiry data changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100021
- Key: 0x06 Code: 0x2a Qualifier: 0x00
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its parameters changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100022
- Key: 0x06 Code: 0x2a Qualifier: 0x01
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its operational mode parameters changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100023
- Key: 0x06 Code: 0x2a Qualifier: 0x02
- Severity: Information
- Description: Device configuration change
- Cause: The device has had its log parameters changed by a device adapter other than the one currently assigned to it.
- Action: No action is necessary.
Event 100024
- Key: 0x06 Code: 0x5c Qualifier: 0x00
- Severity: Information
- Description: Device configuration change
- Cause: The device has reported an RPL status change in response to a request from the device driver.
- Action: No action is necessary.
Event 100025
- Key: 0x01 Code: 0x59 Qualifier: 0x00
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: An updated block has been read from the optical device.
- Action: This message was logged because the operational flags pertaining to logging for the device have been set to log reading of updated blocks. nn No action is necessary.
Event 100026
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x01 Code: 0x18 Qualifier: 0x05
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it. The requested data was successfully returned. Reassignment to a spare area on the medium is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x03
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it using a negative head offset on the medium. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x1e Qualifier: 0x00
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it by recovering the block identifier using the ECC method. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x03
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it using the CIRC method. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x02
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it and automatically reallocate it to the spare area on the medium. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x01
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to use error correction methods and retries to recover it. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x00
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to use error correction methods to recover it. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x08
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it. The requested data was successfully returned. Rewriting the data is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x07
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it. The requested data was successfully returned. Reassignment to a spare area on the medium is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x06
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it and automatically reallocate it to the spare area on the medium without using the ECC method. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x04
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it by retrying the read and/or applying the CIRC method. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x05
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it. The requested data was successfully returned. Rewriting the data is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x02
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it using a positive head offset on the medium. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x01
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it by retrying the read. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x00
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it without using error correction. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x0c Qualifier: 0x01
- Severity: Minor Warning
- Description: Recoverable write error
- Cause: The device was unsuccessful in its first attempt at writing the data for an I/O request, but was able to recover it and reallocate it to a spare area on the medium. The data was successfully written.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: Code: Qualifier:
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it. The requested data was successfully returned. Reassignment to a spare area on the medium is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x17 Qualifier: 0x05
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it using the previous sector identifier on the medium. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100026
- Key: 0x01 Code: 0x18 Qualifier: 0x04
- Severity: Minor Warning
- Description: Recoverable read error
- Cause: The device was unsuccessful in its first attempt at reading the data requested in an I/O request, but was able to recover it using the L-EC method. The requested data was successfully returned.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100027
- Key: 0x02 Code: 0x3e Qualifier: 0x00
- Severity: Minor Warning
- Description: Device cannot be used
- Cause: The device has received an I/O request which it cannot process because it is in the process of configuring itself. The request will be re-tried.
- Action: If diagnostics are being run on this device, that may be the source of this problem. Wait until the diagnostics are complete before attempting to use the device for normal I/O.
Alternatively, the device could be in a state from which it cannot extract itself. Cycle power to the device.
Alternatively, the device has experienced a hardware failure and should be repaired orEvent 100028
- Key: 0x02 Code: 0x04 Qualifier: 0x04
- Severity: Minor Warning
- Description: Device cannot be used
- Cause: The device was not ready to process requests when it received a request from the device driver because its media is being formatted.
- Action: A process has attempted to access the device while another process is formatting its media. Wait until the format is complete before attempting to access the device.
Event 100029
- Key: 0x06 Code: 0x5b Qualifier: 0x01
- Severity: Major Warning
- Description: Excessive errors for device
- Cause: The device has met a pre-set threshold condition for its internal error log.
- Action: Examine the error logs to determine which parameter met the condition. If the condition being tested involves excessive media errors, the medium may need to be replaced. If the medium is non-removable, repair or replace the device, as necessary.
Event 100030
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x0a Qualifier: 0x00
- Severity: Major Warning
- Description: Excessive errors for device
- Cause: The error log for the device has overflowed.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100030
- Key: 0x06 Code: 0x5b Qualifier: 0x02
- Severity: Major Warning
- Description: Excessive errors for device
- Cause: An error log counter for the device has reached its maximum value.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100031
- Key: 0x06 Code: 0x5b Qualifier: 0x03
- Severity: Critical
- Description: Software configuration error
- Cause: The device has exhausted its supply of log list codes while attempting to add a condition to its list to be logged.
- Action: There is a problem with the device configuration. Select no more than the number of codes supported by the device.
Event 100032
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x4e Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: While processing an I/O request, the device received another I/O request, from a device adapter card other than the one designated as the controller for the device. The second request was not processed.
- Action: In a cluster configuration, another controller card is controlling the device. This indicates a problem with the cluster configuration. Correct the configuration.
Event 100032
- Key: 0x06 Code: 0x2f Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device has had its commands cleared by a device adapter card other than the one designated as the controller for the device.
- Action: In a cluster configuration, another controller card is controlling the device. This indicates a problem with the cluster configuration. Correct the configuration.
Event 100033
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x37 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: A parameter passed to the device has had its value rounded. The requested data was successfully returned.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100033
- Key: 0x06 Code: 0x63 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: While processing a command to read data from its medium, the device encountered the end of the user-recorded area on the current track.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100033
- Key: 0x06 Code: 0x39 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device is not capable of saving its operational parameters. No loss of data will occur as a result.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100034
- Key: 0x04 Code: 0x45 Qualifier: 0x00
- Severity: Critical
- Description: Hardware configuration error
- Cause: The device reported that it was unable to perform the requested select or reselect operation. Data loss may occur as a result.
- Action: There could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique, removing devices to reduce the number to seven or less.
Alternatively, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100035
- Key: 0x04 Code: 0x07 Qualifier: 0x00
- Severity: Critical
- Description: Hardware configuration error
- Cause: While attempting to process an I/O request, the device driver was unable to proceed because multiple peripheral devices were in a selected state. The request was not processed.
- Action: There could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique, removing devices to reduce the number to seven or less.
Alternatively, one device on the SCSI bus has failed to respond to a deselection request. Isolate and repair or replace the failing device, as necessary.Event 100036
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x13 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading or writing data for the current I/O request because it could not find the address mark for the data portion of a disk block and was unable to recover. The I/O request, if it was a write data request, has likely caused damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable and if more than one bad block re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100036
- Key: 0x03 Code: 0x12 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading or writing data for the current I/O request because it could not find the address mark for the identification portion of a disk block and was unable to recover. The I/O request, if it was a write data request, has likely caused damage to data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable and if more than one bad block re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100037
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x11 Qualifier: 0x04
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an error on the medium. The data was not recovered, and an attempt to automatically reallocate the data failed. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: Code: Qualifier:
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an error on the medium. The data could not be recovered. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x0c Qualifier: 0x02
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in writing the data for the current I/O request. Reallocating the data to a spare area on the medium was attempted, but failed. Damage to or loss of data has likely occurred.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, the marginal area on the medium can be re-mapped to use a spare area on the medium manually. If more than one re-map operation is required in a day, continuing for two or more successive days, repair or replacement of the device, as necessary, should be considered as a preventative measure.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an error on the medium. The data could not be recovered. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x01
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an error on the medium. The maximum number of retries were attempted and the data could not be read. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x0c
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading the data for the current I/O request. Rewriting the data is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x02
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an error on the medium which was too many bits in length to correct. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x05
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request due to an uncorrectable error on the medium. The request was likely processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Key: 0x03 Code: 0x11 Qualifier: 0x0b
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading the data for the current I/O request. Manual reassignment to a spare area on the medium is recommended.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100037
- Sense Code: 0x15 Qualifier: 0x00
- Sense Key 0x03 SCSI Status 0x02
- See Event 101137 in the NEW Event Listings (SCSI Events, June 2000+) for details.
Event 100037
- Key: 0x03 Code: 0x16 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading or writing data for the current I/O request due to a data synchronization mark error on the medium. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100038
- Key: 0x03 Code: 0x31 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The format of the medium in the device is corrupt. The medium is unusable.
- Action: A format operation in progress on the device may have been interrupted. Restart the formatting process.
Alternatively, the medium in the device is flawed. If the medium is removable, replace the medium.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repaired or replace the device, as necessary.Event 100039
- Key: 0x03 Code: 0x31 Qualifier: 0x01
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in performing a format operation upon its medium. The medium is unusable.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100040
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x19 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so due to a defect list error. The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100040
- Key: 0x03 Code: 0x19 Qualifier: 0x01
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so because the defect list was not available. The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100040
- Key: 0x03 Code: 0x19 Qualifier: 0x02
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so due to an error in the primary defect list . The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100040
- Key: 0x03 Code: 0x19 Qualifier: 0x03
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so due to an error in the grown defect list . The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100041
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x1c Qualifier: 0x02
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so because the grown defect list was not found. The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: If this message appears during a format operation, the message is informational and no action need be taken.
Alternatively, the medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100041
- Key: 0x03 Code: 0x1c Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so because it could not find the defect list . The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: If this message appears during a format operation, the message is informational and no action need be taken.
Alternatively, the medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100042
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x32 Qualifier: 0x01
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so because it could not update the defect list. The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100042
- Key: 0x03 Code: 0x32 Qualifier: 0x02
- Severity: Critical
- Description: Media failure
- Cause: While attempting to spare a block, the device failed to do so because no defect spare location was available. The I/O request that necessitated this action may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100043
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x03 Code: 0x14 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request because it could not find the requested recorded entity on the medium. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100043
- Key: 0x03 Code: 0x14 Qualifier: 0x01
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading data for the current I/O request because it could not find the requested data record on the medium. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100043
- Key: 0x03 Code: 0x06 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: The device was unsuccessful in reading or writing data for the current I/O request because it could not find the reference position on the medium. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The medium in the device is flawed. If the medium is removable, replace the medium with a fresh one.
Alternatively, if the medium is not removable, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100044
- Key: 0x03 Code: 0x57 Qualifier: 0x00
- Severity: Critical
- Description: Media failure
- Cause: While attempting to perform a read operation, the CD-ROM device was unable to read the table of contents stored on the medium. Data loss has likely occurred.
- Action: The medium in the device is flawed. Replace the medium with a fresh one.
Event 100045
- Key: 0x04 Code: 0x53 Qualifier: 0x00
- Severity: Critical
- Description: Physical media error
- Cause: An attempt to load media into the device or eject media from the device has failed.
- Action: The medium is damaged. Replace the medium with a fresh one.
Alternatively, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100046
- Key: 0x00 Code: 0x00 Qualifier: 0x14
- Severity: Critical
- Description: Physical media error
- Cause: While playing an audio compact disc, the device has stopped playing due to an error.
- Action: The compact disc may need cleaning. Clean it in the manner documented in the device manual.
Alternatively, the compact disc may be damaged. Replace it with an undamaged one.Event 100047
- Key: 0x06 Code: 0x5b Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device reported an error log exception while attempting to operate on its internal error log.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100048
- Key: 0x06 Code: 0x5c Qualifier: 0x02
- Severity: Critical
- Description: Hardware failure
- Cause: The spindles of the device are not synchronized for a data transfer that requires it. The request was not processed, but will be retried.
- Action: If, following the bus reset, a message corresponding to this condition appears in the log for this device, the device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100049
- Key: 0x06 Code: 0x4c Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device has failed its self-configuration procedure.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100050
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x4a Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device driver received a command phase error from the device. The I/O request may have been processed in a way which could result in damage to or loss of data.
- Action: The device could be in a state where it could not process the command. Cycle power to the device. If cycling device power does not correct the condition, perform a system shutdown. Cycle power to the computer and wait for it to reboot. If this does not correct the condition, the device has experienced a hardware failure.
Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus to which this device is attached, the device adapter has experienced a hardware failure. Replace it.Event 100050
- Key: 0x06 Code: 0x2c Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device driver received a command sequence error from the device. The I/O request may have been processed in a way which could result in damage to or loss of data.
- Action: The device could be in a state where it could not process the command.
Cycle power to the device. If cycling device power does not correct the condition, perform a system shutdown. Cycle power to the computer and wait for it to reboot. If this does not correct the condition, the device has experienced a hardware failure.
Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus to which this device is attached, the device adapter has experienced a hardware failure. Replace it.Event 100051
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x1b Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While performing a synchronous data transfer, the device encountered an error in the process. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure.
Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this error appear in the log for more than one device on the same SCSI bus, the device adapter has experienced a hardware failure. Replace it.Event 100051
- Key: Code: Qualifier:
- Severity: Critical
- Description: Hardware failure
- Cause: The device driver has received an unspecified hardware error from the device.
- Action: The device has experienced a hardware failure.
Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this error appear in the log for more than one device on the same SCSI bus, the device adapter has experienced a hardware failure. Replace it.Event 100052
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x4b Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device driver received a data phase error from the device. The I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device could be in a state where it could not process the command.
Cycle power to the device. If cycling device power does not correct the condition, perform a system shutdown. Cycle power to the computer and wait for it to reboot. If this does not correct the condition, the device has experienced a hardware failure.
Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus to which this device is attached, the device adapter has experienced a hardware failure. Replace it.Event 100052
- Key: 0x06 Code: 0x00 Qualifier: 0x06
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device terminated the request. The I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device could be in a state where it could not process the command. Cycle power to the device. If cycling device power does not correct the condition, perform a system shutdown. Cycle power to the computer and wait for it to reboot. If this does not correct the condition, the device has experienced a hardware failure. Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus to which this device is attached, the device adapter has experienced a hardware failure. Replace it.Event 100053
- Key: 0x04 Code: 0x10 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device was unsuccessful in processing the current I/O request due to a CRC or ECC error. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100054
- Key: 0x06 Code: 0x2b Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device driver received a status from the device indicating that it could not perform the requested copy data operation because the device adapter could not disconnect from the SCSI bus. The I/O request was not processed.
- Action: The device adapter is in a state where it could not logically disconnect from the SCSI bus. Perform a system shutdown. Cycle power to the computer and wait for it to reboot. If this does not correct the condition, the device adapter has experienced a hardware failure. Replace it.
Event 100055
- Key: 0x04 Code: 0x11 Qualifier: 0x0a
- Severity: Critical
- Description: Hardware failure
- Cause: The device has miscorrected a data error on the medium. The corresponding I/O request has likely been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100056
- Key: 0x04 Code: 0x11 Qualifier: 0x03
- Severity: Critical
- Description: Hardware failure
- Cause: The device was unsuccessful in reading data for the current I/O request because it encountered multiple read errors on the medium and was unable to recover. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100057
- Key: 0x04 Code: 0x44 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device was unsuccessful in processing the current I/O request due to an internal target failure. The request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100058
- Key: 0x04 Code: 0x15 Qualifier: 0x01
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported a mechanical positioning error. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100059
- Key: 0x04 Code: 0x15 Qualifier: 0x02
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device detected an error in positioning the head by reading the medium. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100060
- Key: 0x04 Code: 0x15 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported a random positioning error. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100061
- Key: 0x04 Code: 0x01 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported that it does not have the index/sector signal. The corresponding I/O request has likely been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100062
- Key: 0x04 Code: 0x02 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported that it did not receive the seek complete signal. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100063
- Key: 0x04 Code: 0x03 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported that it was unable to perform the requested write operation due to a peripheral device write fault. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100064
- Key: 0x06 Code: 0x09 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported a track following error. The device head is unable to stay on the assigned track. The corresponding I/O request and subsequent requests may be processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100065
- Key: 0x06 Code: 0x09 Qualifier: 0x01
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported a tracking servo failure. The device head is unable to position to any track. The corresponding I/O request and subsequent requests may be processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100066
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x06 Code: 0x09 Qualifier: 0x02
- Severity: Critical
- Description: Hardware failure
- Cause: While attempting to process an I/O request, the device reported a focus servo failure. The device head is unable to focus on the medium. The corresponding I/O request and subsequent requests may be processed in a way which could cause damage to or loss of data.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100066
- Key: 0x04 Code: 0x09 Qualifier: 0x03
- Severity: Critical
- Description: Hardware failure
- Cause: The servo mechanism that controls the spindle on the device has failed. The device is unusable.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100067
- Key: 0x06 Code: 0x42 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device has failed its power-on self-test.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100068
- Key: 0x06 Code: 0x40 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device has failed its power-on diagnostics for a specified field-replaceable unit.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100069
- Key: 0x06 Code: 0x40 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device has failed its power-on memory test.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Event 100070
- Key: 0x06 Code: 0x47 Qualifier: 0x00
- Severity: Critical
- Description: Hardware failure
- Cause: The device was unsuccessful in processing the current I/O request due to a SCSI parity error. Damage to or loss of data may have occurred.
- Action: The device has experienced a hardware failure. Repair or replace the device, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus to which this device is attached, the device adapter has experienced a hardware failure. Replace it.Event 100071
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: Code: Qualifier:
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device attempted to process a soft reset from the device adapter card but was unsuccessful. A hard reset should be attempted. Data loss caused by I/O's in progress may occur.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100071
- Key: 0x0b Code: 0x46 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device attempted to process a soft reset from the device adapter card but was unsuccessful. A hard reset should be attempted. Data loss caused by I/O's in progress may occur.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100072
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x02 Code: 0x04 Qualifier: 0x03
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device is not in a state where it can process requests. Manual intervention is required. The current I/O request may have been processed in a way that could cause damage to or loss of data.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100072
- Key: 0x04 Code: 0x08 Qualifier: 0x01
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was unsuccessful in its attempt to communicate with one of its logical units due to a time-out condition. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: A segment of the SCSI bus within the device may be damaged. Replace the damaged segment.
Alternatively, the logical unit may be powered down. Power it back up.
Alternatively, one or more of the SCSI cable segments within the device may have become disconnected. Reconnect them.
Alternatively, one or both terminators which belong at the ends of the device's SCSI bus may be missing. Replace them.
Alternatively, the logical unit has experienced a hardware failure and should be repaired or replaced, as necessary.Event 100072
- Key: 0x05 Code: 0x25 Qualifier: 0x01
- Severity: Critical
- Description: Recovered error
- Cause: The High Availability Logical Unit is a global hot spare. It cannot be accessed for data operation from the host. The device was unsuccessful in processing the current I/O request because the request contained a logical unit number, which is not supported for this device. The request was not processed.
- Action: This is an internal error. It indicates that the device is experiencing problems. Please contact H-P support person.
Event 100072
- Key: 0x06 Code: 0x29 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: A Power On, Reset or Bus Device Reset has occurred for the device.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100072
- Key: 0x02 Code: 0x04 Qualifier: 0x02
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was not ready to process requests, initialization is required. This I/O request and all subsequent I/O requests directed to this device will not be processed.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100072
- Key: 0x02 Code: 0x04 Qualifier: 0x01
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was not ready to process requests when it received a request from the device driver because it is in the process of becoming ready.
- Action: The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace it, as necessary.
Alternatively, if messages corresponding to this condition appear in the log for more than one device on the SCSI bus, the device adapter may be in a state from which it cannot extract itself. Perform a system shutdown, cycle power to the computer and wait for it to reboot. If, after reboot, messages corresponding to this condition continue to appear in the log for this SCSI bus, replace the device adapter.Event 100072
- Key: 0x02 Code: 0x04 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was not ready to process requests, but the cause is not reportable.
- Action: If the device is a floppy disk, this message is informational, indicating that I/O was attempted when a diskette was not inserted in the drive. Place a diskette in the drive before trying to use it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Install the terminators in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, if another entry corresponding to this condition appears in the log for this device, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100073
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
- Key: 0x04 Code: 0x41 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was unsuccessful in processing the current I/O request due to a data path failure. The request may have been processed in a way which could cause damage to or loss of data.
- Action: At least one segment of the SCSI bus may be damaged. Replace the damaged segment.
Alternatively, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100073
- Key: 0x04 Code: 0x08 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was unsuccessful in its attempt to communicate with one of its logical units. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: A segment of the SCSI bus within the device may be damaged. Replace the damaged segment.
Alternatively, the logical unit may be powered down. Power it back up.
Alternatively, one or more of the SCSI cable segments within the device may have become disconnected. Reconnect them.
Alternatively, one or both terminators which belong at the ends of the device's SCSI bus may be missing. Replace them.
Alternatively, the logical unit has experienced a hardware failure and should be repaired or replaced, as necessary.Event 100074
- Key: 0x04 Code: 0x05 Qualifier: 0x00
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was unable to select one of its logical units.
- Action: If the device is a disk array, one of its drives was pulled out physically. This in itself will not cause data loss because the disk array can rebuild the data.
Alternatively, if the device is not a disk array, check the following. The device may have been powered off. Power it back on.
Alternatively, one or both of the terminators on the SCSI bus may be missing. Put the terminators back in their proper locations at the ends of the SCSI bus.
Alternatively, the SCSI cable may have become detached from the device. Re-attach the cable.
Alternatively, the SCSI cable may have failed. Replace it.
Alternatively, the device may be in a state where it could not process this, or any, request. Cycle power to the device.
Alternatively, there could be more than one device having the same address on the SCSI bus. Make all the addresses on the SCSI bus unique.
Alternatively, the total length of all cable segments on the SCSI bus exceeds 25 meters. Replace one or more cable segments until the total length is less than this value.
Alternatively, if all of the above fail to correct the problem, the device has experienced a hardware failure. Repair or replace the device, as necessary.Event 100075
- Key: 0x04 Code: 0x08 Qualifier: 0x02
- Severity: Critical
- Description: Device connectivity or hardware failure
- Cause: The device was unsuccessful in its attempt to communicate with one of its logical units due to a parity error. The corresponding I/O request may have been processed in a way which could cause damage to or loss of data.
- Action: A segment of the SCSI bus within the device may be damaged. Replace the damaged segment.
Alternatively, the logical unit has experienced a hardware failure. Repair or replace the logical unit, as necessary.Event 100076
This event has a slightly different description depending on the sense code and sense qualifier reported in the event details. For the exact event reported on your system, find the matching sense code and qualifier below.
Note: With the March 2000 version of STM (IPR 0003), STM version A.20.00, there has been a change to Event 100076. In previous versions of STM, one way to generate Event 100076 is when the OS logs a SCSI Status byte of BUSY (0x08) to the Raw Log. In March 2000 and later versions, a SCSI Status byte of BUSY (0x08) will generate an Event 100100 instead. The message text in Event 100100 more accurately reflects the nature of this event. (There are still many other ways for Event 1000076 to be generated.)
- Key: 0x05 Code: 0x3d Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current identification request message because the message contained invalid bits. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x22 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because the request contained an illegal function code. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x58 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The optical storage device was unsuccessful in processing the current I/O request because the request attempted to access a non-existent generation of data on the medium. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x21 Qualifier: 0x01
- Severity: Critical
- Description: Software configuration error
- Cause: The media changer was unsuccessful in processing the current request message because it would have accessed an invalid element. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x20 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message because the message contained an invalid command operation code. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x25 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because the request contained a logical unit number, which is not supported for this device. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x26 Qualifier: 0x01
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because a parameter in the request is not supported for this type of request. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: Code: Qualifier:
- Severity: Critical
- Description: Software configuration error
- Cause: An attempt was made to process an I/O request for a device, but the device was busy with another request.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x26 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message because the message contained an invalid field in the command parameter list. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x43 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x64 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because the request contained an illegal mode value for the desired track. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: Code: Qualifier:
- Severity: Critical
- Description: Software configuration error
- Cause: A condition has occurred for which SCSI sense data is available. The device driver has not requested the sense data.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x26 Qualifier: 0x03
- Severity: Critical
- Description: Software configuration error
- Cause: An attempt was made to set logging threshold parameters for the device but was unsuccessful because the device does not support threshold parameters. The desired logging may not be performed by the device.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x21 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message because one or more of the logical block addresses for the request was outside the permissible range for the device. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x24 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message because the message contained an invalid field in the command data block. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x26 Qualifier: 0x02
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because a parameter in the request had an invalid value. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: Code: Qualifier:
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x1a Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current I/O request because the parameter list for the request had the wrong length. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x05 Code: 0x49 Qualifier: 0x00
- Severity: Critical
- Description: Software configuration error
- Cause: The device was unsuccessful in processing the current request message because the form of the message was invalid. The request was not processed.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100076
- Key: 0x09 Code: Qualifier:
- Severity: Critical
- Description: Software configuration error
- Cause: The device driver has received an unspecified vendor-specific message from the device.
- Action: This is an internal error, indicating that the installed version of the driver does not match that of the installed version of HP-UX. Install the correct version of the driver.
Event 100077
- Key: 0x06 Code: 0x00 Qualifier: 0x01
- Severity: Information
- Description: Successful completion of operation
- Cause: While processing an I/O request, the tape in the device has reached a filemark on the medium.
- Action: No action is necessary.
Event 100078
- Key: 0x06 Code: 0x00 Qualifier: 0x02
- Severity: Information
- Description: Successful completion of operation
- Cause: While processing an I/O request, the tape in the device has