Event 3
- Severity: CRITICAL
- Event Summary: Array at hardware path 8/12/1/0.8.0.52.0.0.0, path 8/12/1/0.8.0.51.0.0.0: Array with 00800A0B8060EF4 is no longer being monitored.
- Event Class: Array
- Problem Description:
This event message is displayed when a connection cannot be made to the AM60Srvr. The resource monitor will continue to attempt to connect to the AM60Srvr at regular polling intervals. When the AM60Srvr is restored, the connection will succeed and normal operation will continue. Until the AM60Srvr is operating normally, it is not possible to obtain the current status of any of the arrays.- Probable Cause / Recommended Action:
Possible Causes Include:
- The AM60Srvr is not running.
- The wrong version of the AM60Srvr is running.
- The correct AM60Srvr is running, but is hung.
Recommended Action: Restart AM60Srvr, or if still running, stop and restart the AM60Srvr.
- Restart AM60Srvr using the command /opt/hparray/bin/AM60Srvr, or if still running;
- Stop (kill -9 pid; pid: process id of AM60Srvr) and restart the AM60Srvr.
Event 4
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The computer can not connect to the AM60Srvr. The status on the disk array is not currently available.
- Event Class: Array
- Problem Description:
This event message is displayed when a connection cannot be made to the AM60Srvr (Array management daemon for FC60 Storage Array). The resource monitor will continue to attempt to connect to the AM60Srvr at regular polling intervals. When the AM60Srvr is restored, the connection will succeed and normal operation will continue. Until the AM60Srvr is operating normally, it is not possible to obtain the current status of any of the disk arrays.- Probable Cause / Recommended Action:
Possible Causes Include:
- The AM60Srvr is not running.
- The wrong version of the AM60Srvr is running.
- The correct AM60Srvr is running, but is hung.
Recommended Action: Restart AM60Srvr, or if still running, stop and restart the AM60Srvr.
- Restart AM60Srvr using the command /opt/hparray/bin/AM60Srvr, or if still running;
- Stop (kill -9 pid; pid: process id of AM60Srvr) and restart the AM60Srvr.
Event 5
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The controller in slot B is not accessible.
- Event Class: Array
- Problem Description:
This event message is displayed when the controller is not receiving or accepting I/O. If the user did not choose to place the controller offline it may need to be replaced.- Probable Cause / Recommended Action:
Check the path to the indicated controller for a fault condition. If the user did not choose to place the controller offline, it may need to be replaced.Event 6
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The controller in slot A has failed, or is not accessible.
- Event Class: Array
- Problem Description:
This event message is displayed by one of several conditions:
1. Problem with the connection.
2. Interface cable/terminator.
3. Controller.
4. Host but Adapter.- Probable Cause / Recommended Action:
Replace the indicated controller.Event 7
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The diskenclosure controller in enclosure:slot 3:5 has failed, or is not accessible.
- Event Class: Array
- Problem Description:
This event message is displayed when a diskenclosure controller is not accessible.- Probable Cause / Recommended Action:
Check for fault light on diskenclosure.Event 8
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Firmware revisions on the diskenclosure controllers in enclosure 1 do not match.
- Event Class: Array
- Problem Description:
This event message is displayed when a diskenclosure controller reports a different firmware revision than the other diskenclosure controller. This error can only be fixed by downloading firmware to the diskenclosure controllers in the appropriate enclosure.- Probable Cause / Recommended Action:
Download firmware to the diskenclosure controllers in enclosure 1.Event 9
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Both controllers may not have synchronised cache.
- Event Class: Array
- Problem Description:
This event message is displayed when the CMA bit is disabled. The Cache is not synchronized across both the controllers. When a forced Avt occurs, the controller that currently owns the lun is rebooted. CMA bit disappears while the controller reboots. It is set once the controller becomes online. This is a normal operation.- Probable Cause / Recommended Action:
Possible Causes Include:
1. A controller has failed, but no obvious failure mode is evident.
2. A controller is not communicating at all.
Event 10
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 1:2 has failed.
- Event Class: Array
- Problem Description:
This event message is displayed when the disk was marked Failed by the controller, but the cause for the failure is not known (probably because an alternate controller failed this disk).- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 1:2.Event 11
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 2:9 has been removed or replaced.
- Event Class: Array
- Problem Description:
This event message is displayed when the user removed and/or replaced a disk, but the disk was not marked Failed originally.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 2:9.Event 12
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 6:10 is offline.
- Event Class: Array
- Problem Description:
This event message is displayed when the disk is internally marked out of service because data reconstruction failed and a read error occurred for one or more drives in the logical unit LUN. As a result, the affected LUN will be marked Dead, and there may be other drives marked Failed or Offline as a result.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 6:10.Event 13
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 1:1 does not match the block size of the other drive in this logical unit.
- Event Class: Array
- Problem Description:
This event message is displayed when a replaced disk is inserted into the subsystem with the wrong block size.- Probable Cause / Recommended Action:
Check the disk in enclosure:slot 1:1 for fault conditions.Event 14
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 1:1 is too small.
- Event Class: Array
- Problem Description:
This event message is displayed when the disk is replacing a larger disk, and does not have the capacity to support the logical units that would be reconstructed on that disk.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 1:1 with a larger disk.Event 15
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 4:9 has been marked Failed by the user.
- Event Class: Array
- Problem Description:
This event message is displayed when the user marks the disk Failed.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 4:9.Event 16
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 4:2 has been marked Offline by the user.
- Event Class: Array
- Problem Description:
This event message is displayed when the user marks the disk Offline.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 4:2 or reconstruct the drive.Event 17
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: SMART event for drive in enclosure:slot 6:2.
- Event Class: Array
- Problem Description:
This event message is displayed when the indicated drive emits a SMART event. This indicates that the drive may fail and should be replaced.- Probable Cause / Recommended Action:
Replace the drive in enclosure:slot 6:2.Event 18
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 3:2 has been marked Failed (Controller Storage Failure).
- Event Class: Array
- Problem Description:
This event message is displayed when the controller is unable to write subsystem configuration data to the array subsystem data-storage areas on this disk.- Probable Cause / Recommended Action:
Replace the disk in enclosure:slot 3:2.Event 19
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure:slot 3:2 has Failed to rebuild.
- Event Class: Array
- Problem Description:
This event message is displayed when the disk has Failed to rebuild.- Probable Cause / Recommended Action:
Call HP for additional assistance.Event 20
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Fan in enclosure:slot 2:1 is missing or has failed.
- Event Class: Array
- Problem Description:
This event message is displayed when the indicated fan has failed or has been removed.- Probable Cause / Recommended Action:
Replace or install the fan in the indicated slot.Event 21
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Power supply in enclosure:slot 1:3 is missing or has failed.
- Event Class: Array
- Problem Description:
This event message is displayed when the indicated power supply has failed or has been removed.- Probable Cause / Recommended Action:
Possible causes include:
1. A power supply component failure.
2. An external circuit problem.
Replace or install the power supply in the indicated slot.Event 22
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The primary battery has failed.
- Event Class: Array
- Problem Description:
This event message is displayed when the primary battery fails or at boot up, because the battery may be charging.- Probable Cause / Recommended Action:
Replace the battery from the main enclosure.Event 23
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The logical unit 3 has a drive marked Failed, and no action has been taken by the user.
- Event Class: Array
- Problem Description:
This event message is displayed when the logical unit has a drive marked Failed, on which no action has been taken by the user. User data can still be accessed on this logical unit.- Probable Cause / Recommended Action:
Once the drive has been replaced, the controller will reconstruct the drive.Event 24
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The logical unit 2 has been marked Dead.
- Event Class: Array
- Problem Description:
This event message is displayed when the logical unit has been marked Dead (data on it cannot be accessed) because two or more disks have Failed in the same drive group, or one or more disks have Failed in a RAID 0 drive group, or the wrong drive has been removed or replaced.- Probable Cause / Recommended Action:
Reseat the Failed disk.Event 25
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Firmware revisions on controllers A and B do not match.
- Event Class: Array
- Problem Description:
This event message is displayed when a controller has a firmware revision that does not match the other controller. Each controller will operate in a state independently from the other controller. This error can be fixed by downloading firmware from the host to the other controller.- Probable Cause / Recommended Action:
Download the latest firmware to both controllers.Event 26
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The thermal sensor in enclosure 1 has determined that the temperature exceeds the maximum allowable temperature.
- Event Class: Array
- Problem Description:
This event message is displayed when the thermal sensor indicates that the temperature is in excess of the maximum allowable temperature.- Probable Cause / Recommended Action:
Shut down the system to prevent any permanent damage to the system.Event 27
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The controller in slot A has the Write Cache Enable bit disabled.
- Event Class: Array
- Problem Description:
This event message is displayed when the Write Cache Enable bit has been disabled.- Probable Cause / Recommended Action:
Execute the command to reset all the cache bits.Event 28
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The controller in slot A has the Read Cache Disable bit enabled.
- Event Class: Array
- Problem Description:
This event message is displayed when the Read Cache Disable bit has been enabled.- Probable Cause / Recommended Action:
Execute the command to reset all the cache bits.Event 29
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The logical unit 3 has the Write Cache Without Batteries bit enabled.
- Event Class: Array
- Problem Description:
This event message is displayed when the Write Cache Without Batteries bit has been enabled.- Probable Cause / Recommended Action:
Execute the command to reset all the cache bits.Event 30
- Severity: CRITICAL
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The logical unit 3 has the Cache Mirror Enable bit disabled.
- Event Class: Array
- Problem Description:
This event message is displayed when the Cache Mirror Enable bit has been disabled.- Probable Cause / Recommended Action:
Execute the command to reset all the cache bits.Event 31
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: LUN Configuration details are stored in files alias_id.date in log path /var/opt/hparray/log for every 24 hours, if differences are found.
- Event Class: Array
- Problem Description:
This event message is information from the monitor to notify the difference found in LUN Configuration in 24 hours. This helps to recover a missing or defective LUN by looking at the details stored in files.- Probable Cause / Recommended Action:
No action required.Event 32
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: UTM LUN status is disabled.
- Event Class: Array
- Problem Description:
This event message is information from the monitor to notify that the controller firmware does not support UTM LUN.- Probable Cause / Recommended Action:
Upgrade controller firmware to the latest.Event 33
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure: slot 1:1 has been activated as GHS disk.
- Event Class: Array
- Problem Description:
This event message is displayed when the user activates the disk as a GHS disk.- Probable Cause / Recommended Action:
No action required.Event 34
- Severity: MAJOR_WARNING
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: GHS Disk in enclosure: slot 4:9 has been deactivated.
- Event Class: Array
- Problem Description:
This event message is displayed when the user has deactivated the GHS disk.- Probable Cause / Recommended Action:
No action required.Event 35
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0 : Disk in enclosure: slot 4:2 has been physically inserted by the user.
- Event Class: Array
- Problem Description:
This event message is displayed when the user inserts a disk in the enclosure.- Probable Cause / Recommended Action:
No action required.Event 36
- Severity: INFORMATION
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: Disk in enclosure: slot 4:2 has been physically removed by the user.
- Event Class: Array
- Problem Description:
This event message is displayed when the user removes the disk from the enclosure.- Probable Cause / Recommended Action:
Replace disk in enclosure: slot 4:2.Event 37
- Severity: SERIOUS
- Event Summary: Disk Array at hardware path : Array at hardware path 8/12.8.0.5.0.0.0, path 8/8.8.0.4.0.0.0: The Logiles in /var/opt/hparray/log directory have been corrupted or non-existent.
- Event Class: Array
- Problem Description:
This event message is displayed when the Logiles could not be opened or read. MEL Events would not be monitored by fc60mon.- Probable Cause / Recommended Action:
To restart MEL Event monitoring:
- Stop the AM60Srvr (Kill -9 pid; pid: process id of AM60Srvr).
- Delete the contents of the /var/opt/hparray/log folder.
- Restart the AM60Srvr (Run /opt/hparray/bin/AM60Srvr).
Event 100
- Severity: Information
- Event Summary: Disk at hardware path x/x.x.x : Device added to monitoring
- Event Class: I/O
- Problem Description:
The device has been added to the set of devices being monitored by this monitor.- Probable Cause / Recommended Action
The device was added to the system, has started responding to the system.
The /var/stm/data/os_decode_xref file was modified to add information indicating this device is now supported by this monitor.
If the device is in the DOWN state and this monitor does not control setting the state of the device to UP (check by running the "/etc/opt/resmon/lbin/set_fix ed -L" command), use the "/etc/opt/resmon/lbin/set_fixed -n " command to set the state of the device to UP.- Automated Recovery: None
- Event Generation Threshold: 1 occurrence
Event 101
- Severity: Critical
- Event Summary: Disk at hardware path x/xx/x.x.x : Device removed from monitoring
- Event Class: I/O
- Problem Description:
The device has been removed from the list of devices being monitored by this monitor.- Probable Cause / Recommended Action
The device was removed from the system, has stopped responding to the system or it has been replaced with a device that is not supported by this monitor.
Run ioscan to determine the state and type of the device.
Check the /var/stm/data/os_decode_xref for the information indicating which devices are supported by this monitor.
Check other monitors to determine if they are now monitoring the device by running /etc/opt/resmon/lbin/monconfig and using the "Check monitoring" command.- Automated Recovery: None
- Event Generation Threshold: 1 occurrence
Event 103
- Severity: Information
- Event Summary: Test event
- Event Class: Memory
- Problem Description:
This is a test message from the monitor to test the communication path from the monitor to the notification mechanism.- Probable Cause / Recommended Action
No action required.- Automated Recovery: None
- Event Generation Threshold: 1 occurrence